Daewoo Erf 396 Service Manual
Here you can view all the pages of manual Daewoo Erf 396 Service Manual. The Daewoo manuals for Fridge freezer are available online for free. You can easily download all the documents as PDF.
Page 31
16. R-SENSOR OFF POINT ADJUSTING OPTION 1) R-SENSOR OFF POINT can be adjusted by changing the input voltage of MICOM 26 pin. 2) The default of input voltage is 0V. 3) The changed OFF POINT is base OFF POINT + OFF POINT of input voltage. 4) The change of R-SENSOR OFF POINT depend on the input voltage of MICOM MICOM Input (V) 0 1.0 1.5 2.0 2.5 3.7 5.0 OFF POINT Variation (ºC) -0.5ºC (DEF) 1.0ºC down 2.0ºC down 3.0ºC down 1.0ºC up 2.0ºC up 3.0ºC up R26, R27 Resistan ce...
Page 32
13.2. ERF-XXXN NO FUNCTION CONTENTS 1. DISPLAY - Temperature control of Refrigerator Maximum angle clockwise : Temperature setting for SUPER Maximum angle counter-clockwise : Temperature setting for VACATION Maximum rotation : 280±10° Minimum Step Difference : 0.7 deg/28° Total step Difference : 6.3 deg ERROR LED DISPLAY (ON MAIN PCB) DISPLAY ¦++Ù LED +ÔÀ-ã-ó ?FUNCTION DISPLAY - D1 ERROR : LED is off & on one time. - D2 ERROR : LED is off & on two times. - R1 ERROR : LED is on &...
Page 33
2. TEMPERATURE ADJUSTMENT & CONTROL 1) TEMPERATURE ADJUSTMENT 1.1- TEMPERATURE ADJUSTMENT TEMP CONTROL DIAL is rotated VAC , LOW, MIDDLE, HIGH, SUPER. TEMPERATURE will be set if the Dial doesn’t get rotated again within 5 sec 1.2- FORCED DEFROST : Button of M-PCB(SW2) is pushed 1 time. 1.3- SHORT CIRCUIT OPERATION : Button of M-PCB(SW2) is pushed 2 times. 2 )TEMPERATURE CONTROL 2.1- COMP will be controlled by the on/off point of R-Sensor at each mode. 2.2- STEP DIFF of ROOM R : 1.4 deg...
Page 34
4. SUPER - Rotate TEMP. CONTROL Dial and make Super Location ON POINT: 0.05°C OFF POINT: -2.95°C 5. DETERMINATION OF DEFROST - Starting condition of Defrost Mode - When accumulated running time of comp. is 8, 10, 12, 18, 30hrs. - After Checking the condition ‘2.1’ if total time(COMP on time + COMP off time) is more than 24, 48, 36, 72hrs, then defrost mode starts immediately. Accumulated running time of COMP Total running time of COMP RT-SENSOR Door Open Door Close Door Open Door...
Page 35
9. ERROR DISPLAY & CONTROL * ERROR DISPLAY a. When error happens, it is displayed on led lamp.(Main PCB LED 1) 1) R1 ERROR (It happens when R-SENSOR is OPEN or SHORT) 1.1- DISPLAY : On & off one time while LED is on. 1.2- CONTROL : Controlled by the condition of RT (Unit : min) RT-S TEMP RT-S ERROR 19ºC Down 20ºC Up COMP. Operating TIME (ON / OFF) 20 / 30 15 / 35 22 / 28 1.3- CANCEL : when R-SENSOR is working normally. 2) D1 ERROR (It...
Page 36
15. FUNCTION OF LOW ROOM TEMPERATURE 1) Condition of LOW RT TEMP : 1.1- LOW RT A : RT SENSOR RT-S < 19ºC 2) Control 2.1- When Comp. is on, R-SENSOR HTR is off. When it passes 6 min after COMP. is off, R-SENSOR HTR is on until COMP is on. 2.2- COMP. can’t be on within 40 min. after COMP. is off. 2.3- When it is not the Mode of LOW ROOM TEMP. or RT-SENSOR is on ERROR(open or short), R-SENSOR HTR is off. - LOW RT TEMP A Condition R-SENSOR Operating Temperature 1ºC up - LOW RT TEMP B...
Page 37
5) APPLICATION (MAIN PCB) 5.1- GENERAL: MICOM 26 port - 0V 5.2- DELETE J2 (CHANGING R OFF POINT 1DEG UP) : MICOM 26 port – 2.5V LOW COOLING OPTION a. R-SENSOR OFF POINT ADJUSTMENT (1 DEG. DOWN) b. J1 DELETION on LOW COOLING OPTION Default resistance (31.4 KOhms) + 1.5 KOhms = 32.9 KOhms Operating on condition that R-SENSOR OFF point goes down 1ºC. 36
Page 38
DAEWOO ELECTRONICSMANUFACTURING ESPAÑA S.A Polígono industrial de Júndiz C/Zurrupitieta 27, 01015 Vitoria, Spain Tel: 00 34 945292292 Fax:00 34 945290965