16. R-SENSOR OFF POINT ADJUSTING OPTION 1) R-SENSOR OFF POINT can be adjusted by changing the input voltage of MICOM 26 pin. 2) The default of input voltage is 0V. 3) The changed OFF POINT is base OFF POINT + OFF POINT of input voltage. 4) The change of R-SENSOR OFF POINT depend on the input voltage of MICOM MICOM Input (V) 0 1.0 1.5 2.0 2.5 3.7 5.0 OFF POINT Variation (ºC) -0.5ºC (DEF) 1.0ºC down 2.0ºC down 3.0ºC down 1.0ºC up 2.0ºC up 3.0ºC up R26, R27 Resistan ce (kOhms) Jumper adoption R27 : 40 R26 : 10 R27:23.3 R26:10 R27:15 R26:10 R27:10 R26:10 R27:3.5 R26:10 R27:10 R26:DEL 5) APPLICATION (MAIN PCB) 5.1- GENERAL: MICOM 26 port - 0V 5.2- DELETE J2 (CHANGING R OFF POINT 1DEG UP) : MICOM 26 port – 2.5V LOW COOLING OPTION - R-SENSOR OFF POINT ADJUSTMENT (1 DEG. DOWN) - J1 DELETION on LOW COOLING OPTION Default resistance (31.4 Kohms) + 1.5 kohms = 32.9 Kohms Operating on condition that R-SENSOR OFF point goes down 1ºC. 30
13.2. ERF-XXXN NO FUNCTION CONTENTS 1. DISPLAY - Temperature control of Refrigerator Maximum angle clockwise : Temperature setting for SUPER Maximum angle counter-clockwise : Temperature setting for VACATION Maximum rotation : 280±10° Minimum Step Difference : 0.7 deg/28° Total step Difference : 6.3 deg ERROR LED DISPLAY (ON MAIN PCB) DISPLAY ¦++Ù LED +ÔÀ-ã-ó ?FUNCTION DISPLAY - D1 ERROR : LED is off & on one time. - D2 ERROR : LED is off & on two times. - R1 ERROR : LED is on & off one time. - RT ERROR : LED is on & off two times. - DR ERROR : LED is on continually - Buzzer sounds if any button of M-PCB(SW2) is pushed. - FORCED DEFROST OF CONDITION : Button of M-PCB(SW2) is pushed 1 time. - SHORT CIRCUIT OF CONDITION : Button of M-PCB(SW2) is pushed 2 times. 31
2. TEMPERATURE ADJUSTMENT & CONTROL 1) TEMPERATURE ADJUSTMENT 1.1- TEMPERATURE ADJUSTMENT TEMP CONTROL DIAL is rotated VAC , LOW, MIDDLE, HIGH, SUPER. TEMPERATURE will be set if the Dial doesn’t get rotated again within 5 sec 1.2- FORCED DEFROST : Button of M-PCB(SW2) is pushed 1 time. 1.3- SHORT CIRCUIT OPERATION : Button of M-PCB(SW2) is pushed 2 times. 2 )TEMPERATURE CONTROL 2.1- COMP will be controlled by the on/off point of R-Sensor at each mode. 2.2- STEP DIFF of ROOM R : 1.4 deg 2.3- Middle OFF point of ROOM R : -0.15°C 2.4- ON/OFF DIFF of ROOM R : 3 deg ON -í OFF -í2.85¡É-0.15¡É5.65¡É2.65 ¡É0.05 ¡É-2.95¡É1.25¡É-1.55¡É1.45¡É4.25¡É 3 )FORCED DEFROST 3.1- Defrost mode will be Started independent of the cycle. 3.2- The flow is same as the general defrost mode flow. 4 )SHORT CIRCUIT OPERATION 4.1- COMP & FAN will be on independent of the operation condition. 4.2-The time limit of SHORT CIRCUIT OPERATION: 60 hrs 3. VACATION - Rotate TEMP. CONTROL Dial and make Vacation Location. ON POINT: 5.65°C OFF POINT: 2.65°C 32
4. SUPER - Rotate TEMP. CONTROL Dial and make Super Location ON POINT: 0.05°C OFF POINT: -2.95°C 5. DETERMINATION OF DEFROST - Starting condition of Defrost Mode - When accumulated running time of comp. is 8, 10, 12, 18, 30hrs. - After Checking the condition ‘2.1’ if total time(COMP on time + COMP off time) is more than 24, 48, 36, 72hrs, then defrost mode starts immediately. Accumulated running time of COMP Total running time of COMP RT-SENSOR Door Open Door Close Door Open Door Close RT 29°C Up 8HR 18HR 24HR 36HR 20
9. ERROR DISPLAY & CONTROL * ERROR DISPLAY a. When error happens, it is displayed on led lamp.(Main PCB LED 1) 1) R1 ERROR (It happens when R-SENSOR is OPEN or SHORT) 1.1- DISPLAY : On & off one time while LED is on. 1.2- CONTROL : Controlled by the condition of RT (Unit : min) RT-S TEMP RT-S ERROR 19ºC Down 20ºC Up COMP. Operating TIME (ON / OFF) 20 / 30 15 / 35 22 / 28 1.3- CANCEL : when R-SENSOR is working normally. 2) D1 ERROR (It happens when D-SENSOR is OPEN or SHORT) 2.1- DISPLAY : On & off one time while LED is off. 2.2- CONTROL : Return to the limit defrost time of Defrost (30 min) 3) D2 ERROR (It happens when heater is off by time ? 80 min). 3.1- DISPLAY : On & off two times while LED is off. 3.2- CONTROL : Return to next limit defrost time (80 min) 4) RT ERROR (It happens when RT-SENSOR is OPEN or SHORT) 4.1- DISPLAY : On & off two times while LED is on. 4.2- CONTROL : The system is normally operating but the controlling by RT- SENSOR doesn’t work. 4.3- CANCEL : when RT-SENSOR is working normally. 5) DR ERROR 5.1- Display : LED is on continuously 5.2- Control : Deletion of function related door switch sensing 5.3- If door switch(open & close) is sensed, the error is terminated automatically. 10. SHORT CIRCUIT TEST 1) START : Button of M-PCB(SW2) is pushed 2 times and SW1 6 times. 2) CANCEL : Button of M-PCB(SW2) is pushed 1 time. Cf. the system generally operates after the limit time 60 hrs. passes. 3) CONTROL : COMP & FAN will be on independent of the operating condition. (There is no defrost mode on this test.) 11. FUNCTION OF TIME REDUCTION 1) HOW TO REDUCE: (There is no FAST KEY on PCB for MP.) 1 min : Click FAST KEY one time 30 min : If you press FAST KEY continuously, you can reduce 30 minutes on each second. 2) Practical Use : Can be applied to reduce needless time on test. EX) function of stop for 6 min 34
15. FUNCTION OF LOW ROOM TEMPERATURE 1) Condition of LOW RT TEMP : 1.1- LOW RT A : RT SENSOR RT-S < 19ºC 2) Control 2.1- When Comp. is on, R-SENSOR HTR is off. When it passes 6 min after COMP. is off, R-SENSOR HTR is on until COMP is on. 2.2- COMP. can’t be on within 40 min. after COMP. is off. 2.3- When it is not the Mode of LOW ROOM TEMP. or RT-SENSOR is on ERROR(open or short), R-SENSOR HTR is off. - LOW RT TEMP A Condition R-SENSOR Operating Temperature 1ºC up - LOW RT TEMP B Condition R-SENSOR Operating Temperature 16. R-SENSOR OFF POINT ADJUSTING OPTION 1) R-Sensor OFF Point can be adjusted by changing the input voltage of Micom 26 pin. 2) The default of input voltage is 0V. 3) The changed OFF Point is base OFF POINT + OFF POINT of input voltage. 4) The change of R-SENSOR OFF POINT depend on the input voltage of MICOM MICOM Input (V) 0 1.0 1.5 2.0 2.5 3.7 5.0 OFF POINT Variation (ºC) -0.15ºC (DEF) 1.0 Down 2.0 Down 3.0 Down 1.0 Up 2.0 Up 3.0 Up R26, R27 Resistan ce (KOhms) Jumper adoption R27 : 40 R26 : 10 R27:23.3 R26:10 R27:15 R26:10 R27:10 R26:10 R27:3.5 R26:10 R27:10 R26:DEL 35
5) APPLICATION (MAIN PCB) 5.1- GENERAL: MICOM 26 port - 0V 5.2- DELETE J2 (CHANGING R OFF POINT 1DEG UP) : MICOM 26 port – 2.5V LOW COOLING OPTION a. R-SENSOR OFF POINT ADJUSTMENT (1 DEG. DOWN) b. J1 DELETION on LOW COOLING OPTION Default resistance (31.4 KOhms) + 1.5 KOhms = 32.9 KOhms Operating on condition that R-SENSOR OFF point goes down 1ºC. 36