Page 21

11. EXPLODE DRAWING20 

Page 22

21 

Page 23

366N366A396N396A416N416A
1SHELF GLAS AS3017839400223333
2COVER GLAS C/C AS3011497900111111
3CASE CHILD3011181400111111NANO SILVER
4DOOR CHILLED CASE3011760500111111NANO SILVER
5COVER VEGTB CASE
3011497700111111
6KNOB HUMIDITY3013410800222222
CASE VEGETABLE *L3011181900111111NANO SILVER
CASE VEGETABLE *R3011182000111111NANO SILVER
8CASE ICING3011163200111111
9CASE F D
3011181800111111
CASE F B AS301118490022----BLUE MILKY
CASE F C AS
3011185000 - -2222BLUE MILKY
11CASE F A AS3011184800111111BLUE MILKY...

Page 24

366N366A396N396A416N416A
37BUTTON F-CP3016304300-1-1-1 
38F-PCB AS30143C6160-1-1-1
39GASKET R DOOR AS301230660011----
3012306800--1111
40HANDLE R301264000011111103 SILVER
DMS2640010111111SNOW WHITE
41COVER HNDL SCREW301149520044444403 SILVER
DMS1495210444444SNOW WHITE
42SPECIAL SCREW3016033600444444
43ASSY R DR A/S 366A SWDMS0060000-1----GRIP S-WHITE
ASSY R DR A/S 366A SVDMS0060010-1----GRIP SILVER
ASSY R DR A/S 366N SWDMS00601001-----GRIP S-WHITE
ASSY R DR A/S 366N SVDMS00601101-----GRIP SILVER
ASSY R...

Page 25

366N366A396N396A416N416A
71CASE VAPORY3011162700111111 
72FIXTURE COMP3012005300222222
73DRYER ASSY3016802203111111
74COMPRESSORDMS0A00100111111
75ABSORBER COMP3010103400444444
76SCREW MACHINEDMS1B00100111111
77SPECIAL WASHERDMS1B00200111111
78PIPE CHARGE3014418211111111
79HARNESS EARTH3012735220111111
80BASE COMP-111111
81SPECIAL SCREW A3016004300444444
82CAPACITOR RUNDMS6402129111111
83SPECIAL WASHER R/CDMS6006510111111
84SPECIAL NUT R/CDMS6006410111111
85RELAY BOXDMS0527900111111
86CLAMP CORD...

Page 26

13. PCB CONTROL FUNCTION 
 
13.1. ERF-XXXA 
NO FUNCTION CONTENTS 1. 
DISPLAY  
1) VAC STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 1 TIME. 
2) LOW STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 2 TIMES. 
3) MID STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 3 TIMES. 
4) HIGH STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 4 TIMES. 
5) SUPER STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 5 TIMES. 
6) ERROR LED DISPLAY (ON MAIN PCB) ?FUNCTION DISPLAY 
- D1 ERROR : LED is off & on one time. 
- D2 ERROR : LED is...

Page 27

  2. TEMPERATURE 
ADJUSTMENT 
& 
CONTROL 1) TEMP. CONTROL SWITCH 
1.1- TEMP. CONTROL  
When TEMP CONTROL button is pressed, the led lamps MIDLE - HIGH - 
SUPER - VAC -LOW - MIDDLE will be on in sequence. 
TEMPERATURE will be set if the button doesn’t get pressed again within 5 sec 
1.2- FORCED DEFROST: will be start when this button pushed for over 5 seconds 
continuously. 
1.3- SHORT CIRCUIT  OPERATION: will be started and stopped when this button 
pushed over 30 times. 
2) TEMPERATURE CONTROL 
2.1-...

Page 28

  4. SUPER  - Press TEMP. CONTROL button and make SUPER led lamp on. 
ON POINT: 0.05°C 
OFF POINT: -2.95°C 5. Determination of 
DEFROST 1) Starting condition of Defrost Mode 
1.1- When accumulated running time of comp. Is 8, 10, 12, 18, 30hrs. 
 1.2- After Checking the condition ‘1.1’ if total time (COMP on time + COMP off time) 
is more than 24, 36, 48, 72hrs, then defrost mode starts immediately.  
 
Accumulated running time of 
COMP Total running time of COMP  
RT-SENSOR 
Door Open Door Close Door...

Page 29

  9. ERROR 
DISPLAY 
& 
CONTROL - ERROR DISPLAY 
-  When error happens, it is displayed on led lamp.(Main PCB LED 1) 
 
1) R1 ERROR (It happens when R-SENSOR is OPEN or SHORT) 
1.1- DISPLAY : On & off one time while LED is on. 
1.2- CONTROL : Controlled by the condition of RT 
                                                         (Unit : min) 
RT-S TEMP RT-S ERROR 19ºC Down 20ºC Up COMP. Operating TIME (ON / OFF) 20 / 30 15 / 35 22 / 28  1.3- CANCEL : when R-SENSOR is working normally. 
2) D1 ERROR...

Page 30

  12. POWER ON / OFF 1) START : Press POWER button 
2) CANCELATION : Press POWER button again 
3) DISPLAY 
- START : All LED lamps are off and power is off.(COMP, Heater, Lamp of Room) 
- CANCEL : Return to the last condition(dial) 13. MEMORY SAVING 
ON POWER 
FAILURE -After power failure or momentary power failure happens, if power is back on, the mode 
will be returned on last condition. 14. EEPROM CLEAR -Make EEPROM clear right before shipping (set the initial mode) 
-How to clear : press REF.TEMP....