Page 131
Chapter 5: Web-Based Management GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 127 MAC Filtering By filtering MAC address, the switch can ea sily filter the pre-configured MAC address and reduce the un-safety. You can add and delete filtering MAC address. Figure 5-69: MAC Filtering interface This page includes the following fields: Object Description MAC Address: Enter the MAC address that you want to filter. All MAC Addresses You can view all of the MAC addresses learned by the...
Page 132
Chapter 5: Web-Based Management 128 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual Figure 5-70: All MAC Address interface Multicast Filtering Multicasts are similar to broadcasts, they are sent to all end stations on a LAN or VLAN. Multicast filtering is the function, which end stations can receive the multicast traffic if the connected ports had been includ ed in the specific multicast groups. With multicast filtering, network devices only forw ard multicast traffic to the ports that are...
Page 133
Chapter 5: Web-Based Management GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 129 Digital Input/Output (GE-DSH-73) The 7 10/100TX + 3 10/100/1000T/100/1000 SFP Combo w/ X-Ring L2 Managed \ Industrial Switch contains two digital inputs and two digital outputs. The digital inputs may be used to receive the voltage-chang ing signal of the remote equipment to sense the state of the remote equipment like heater, pump, and other electrical equipment. Therefore the switch can be co nfigured to send...
Page 134
Chapter 5: Web-Based Management 130 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual • Condition: The system will send an electric al Low-to-High or High-to-Low signal to First Digital Output (DO0)/Second Digita l Output (DO1) when the condition of ticked checkbox is met. o Port Fail: Having ticked this checkbox , DO0/DO1 will output an electrical Low- to-High or High-to-Low signal when port failure occurs. o Power Fail: Having ticked this checkb ox, DO0/DO1 will output an electrical Low-to-High...
Page 135
Chapter 5: Web-Based Management GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 131 Power Over Ethernet (GE-DSH-82-PoE) Providing up to 8 PoE, in-line power inte rface, the GE-DSH-82-PoE Industrial PoE Switch can easily build a power central- controlled IP phone system, IP Camera system, AP group for the enterprise. For instance, 8 camera / AP can be easily installed around the corner in the com pany for surveillance demands or build a wireless roaming environment in the office. Without the...
Page 136
Chapter 5: Web-Based Management 132 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual Power Management In a power over Ethernet system, operating power is applied from a power source (PSU-power supply unit) over the LAN infrastr ucture to powered devices (PDs), which are connected to ports. Under some condit ions, the total output power required by PDs can exceed the maximum available powe r provided by the PSU. The system may a prior be planed with a PSU capable of su pplying less power than the...
Page 137
Chapter 5: Web-Based Management GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 133 This page includes the following fields: Object Description Maximum Power Available Displays the maximum power supply in Watt. Actual Power Consumption This column shows the real-time total power consumption. System Power Limit User can modify the value to this column field to limit the total output power for the system. Main Supply Voltage This column shows the ou tput voltage of the system for PoE ports....
Page 138
Chapter 5: Web-Based Management 134 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual Object Description Determined Class Displays the PD’s class. Class 0 is the default for PDs. However, to improve power management at the PSE, the PD may opt to provide a signature for Class 1 to 3. The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input voltages and operational modes. A PD shall return Class 0 to 3 in accordance with the maximum...
Page 139
Chapter 5: Web-Based Management GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 135 Factory Default Reset switch to default configuration. Click to reset all configurations to the default value. Figure 5-75: Factory Default interface Save Configuration Save all configurations that you have made in the system. To ensure the all configuration will be saved. Click SAVE to save the all config uration information to flash memory. Figure 5-76: Save Configuration interface
Page 140
Chapter 5: Web-Based Management 136 GE-DSH-73/DSH-82 and DSH-82-PoE User Manual System Reboot Reboots the switch with a software reset. Click REBOOT to reboot the system. Figure 5-77: System Reboot interface