Comdial Executech 1432 KSU Instructions Manual
Here you can view all the pages of manual Comdial Executech 1432 KSU Instructions Manual. The Comdial manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 21
IMI 66-036 Installation l----1 CONNECT TO CLIP TERMINALS ON . I t-l-- CONNECTOR BLOCK PER CHART + 1 ~KNSTUERNAL ’ LOW 1 SWITCHING >,- _ I, 24v %Z MAX OUTPUT AS A 40V @ .5A MAX REQUIRED BY RELAY COIL VOLTAGE ( 1 POWER . Y - SUPPLY I -- - -- -1 AC , VOLTAGE CLAMPING DIODE RECOMMENDED FUNCTION COMMON AUDIBLE STATION 17 RINGING CONNECTIONS J-l CLIPS 49, 50 J-2 CLIPS 49, 50 Figure 2-2. Common Audible/Auxiliary Station Interface Wiring (Typical Connection) 600 - TO 600 wk(l:l)...
Page 24
Installation SYSTEM CHECKOUT Initial Condition - The system operating features are set to a set of default conditions at initial power up. These conditions provide a basic operating system with a known set of parameters, and the system should be initially checked out with the default conditions in place. At anytime while the system is operating, default conditions can be reset from station port 10 or 11 per the instructions provided in Chapter 3. Check Out Check the KSU and telephone...
Page 25
IMI 66-036 Installation Voltage Check Make the following voltage measurements at the station connector blocks under the following conditions 0 Bridging clips installed @ AC power connected to the KSU Measure the voltage across one voice line and one data line and then across the other voice line and the other data line for each even and odd station. The measured voltage must be as follows: L UNIT UNDER TEST 66M-xx BLOCK METER LEAD MEASURED CONNECTION POLARITY VOLTAGE TYPICAL EVEN Voice...
Page 26
ItiI 66-036 Programming CHAPTER3 SYSTEMPROGRAMMING GENERAL INFORMATION l Class Of Service (COS) programming consists of the following major categories: .Station COS. General System COS, Toll Table Entry, Line COS, and l All COS programming commands must originate at a 22 Line/Feature Keyset installed at station port 10 or 11 and a companion DSS/BLF Console installed at adjunct port 10 or 11 respectively. No COS programming commands will be accepted from any other stations connected to the...
Page 27
IlyI 66-1)36 .I Programming SPECIAL PROGRAMMING RE~UIRk9lENTS SINGfX-LIidE KEYSiE!lS Several programming steps under COS programming must be observed for proper operation of a Single-Line Keyset. . @ When the system is strapped for key system configuration, the Single-Line tieyset is an intercom only station. It can be configured for private line only by programming the applicable station port for the prime line automatic feature. When the port is programmed with the prime line automatic...
Page 28
IMI 66-036 Programming BASE LEVEL PROGRAM ENTRY MODE I The first step in any COS programming sequence is to enter the base level programming mode from station port 10 or 11 (port 10 only for KSU rev. A through M). Once in this mode, COS can be set as desired. To enter base level: 1. Press the ITCM key. The dial tone will sound. 2. Press the following keys in sequence: * 7 4 6 Note that the dial tone stops and a tone burst sounds to indicate that the base level programming mode is entered....
Page 29
IMI 66-036 Programming PROGAMMING OVERLAYS Several different telephone and console overlays are packed with the system. The overlay to be used is dependent upon the particular models of equipment connected to the programming station port (10 or 11) and. the respective adjunct port (10 or 11). illustrated in Figure 3-1. The programming overlays are Full-scale copies of the overlays are also included at the end of this chapter. The full-scale copies can be removed and prepared for use if needed....
Page 30
IMI 66-036 Programming SYSTKM COS PROGRAMMNG PROCEDURE f------------------------------------------------- SYSTrGl DEFAULTS 0 Recall/flash time = 2 seconds 0 Intercom signalling = voice first 0 Pause time = 1 second l Central message Desk = not assigned 0 Timed Hold recall time l Unanswered call transfer = 60 seconds = 20 seconds 0 Printer baud rate = 1200 baud, 7-bit data l Print length = 40 Col. 0 Port Assignments: All station ports= 22 Line/Feature Keyset All ad]unct ports = 40-Key...