Page 301
1-93 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Air Filter Assembly on a Catalyst 6509-NEB-A Switch or a Catalyst 6509-V-E (Optional) Installing the Air Filter Assembly on a Catalyst 6509-NEB-A Switch or a Catalyst 6509-V-E (Optional) This section describes how to install the optional air filter assembly for the Catalyst 6509-NEB-A switch or the Catalyst 6509-V-E switch. The filter assembly is designed to prevent dust...
Page 302
1-94 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Air Filter Assembly on a Catalyst 6509-NEB-A Switch or a Catalyst 6509-V-E (Optional) Step 2Install the new intake panel by tightening four thumbscrews. (See Figure 1-74.) Figure 1-74 Installing the New Intake Panel Step 3 Remove the inner filter retainer from the filter cage assembly by depressing the thumb loops and carefully sliding filter retainer outwards. (See Figure...
Page 303
1-95 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Air Filter Assembly on a Catalyst 6509-NEB-A Switch or a Catalyst 6509-V-E (Optional) Figure 1-75 Removing the Inner Filter Retainer Step 4 Place the foam filter over the filter retainer. (See Figure 1-76.) Step 5Slide the retainer and filter into the cage assembly. 1Filter cage assembly3Thumb loops 2Filter retainer4Ta b s 104898 1 23 4
Page 304
1-96 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Air Filter Assembly on a Catalyst 6509-NEB-A Switch or a Catalyst 6509-V-E (Optional) Figure 1-76 Placing the Foam Filter Over the Filter Retainer Step 6 Install the filter assembly with the tabs facing the floor, as follows: a.Fit the tabs (see Figure 1-76) on the bottom of the filter cage assembly into the lower support loops. (See Figure 1-74.) b.Rotate the filter...
Page 305
1-97 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Air Filter Assembly on a Catalyst 6509-NEB-A Switch or a Catalyst 6509-V-E (Optional) Figure 1-77 Installing the Filter Assembly Step 7 After installing the optional air filter assembly, establish a schedule for visually checking the air filter for contamination. (See “Checking the Air Filter” section on page 1-98.) 1Thumbscrews2Fastening screw 104900 INPUT OKFA N OKOUTPUT...
Page 306
1-98 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Remote Power Cycling Feature Control Wires (Optional) Checking the Air Filter Once you have installed the optional air filter assembly on the Catalyst 6509-NEB-A or Catalyst 6509-V-E switch chassis, you need to periodically check the air filter for damage and cleanliness. We recommend that you perform a visual inspection of the filter at least once a month, or more often...
Page 307
1-99 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Remote Power Cycling Feature Control Wires (Optional) Required Tools and Components The following tools and components are required to perform this procedure: Relay controller box. We strongly recommend that you purchase a relay controller box that uses a NO (normally open) relay to control the remote power cycling. Small flat-blade screwdriver 18 AWG (maximum) control...
Page 308
1-100 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Remote Power Cycling Feature Control Wires (Optional) Figure 1-78 Installing the Relay Control Wires Step 8 Check the position of the relay controller switch located next to the terminal block. The switch should be in the down, NO (normally open) position if the relay controller box uses a NO relay. This the default and the recommended position. If the relay controller...
Page 309
1-101 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Remote Power Cycling Feature Control Wires (Optional) To install the ferrite bead on the remote power-cycling control wires, follow these steps: Step 1Remove the ferrite bead and the two plastic ties from the plastic bag. Step 2Open the ferrite bead as shown in Figure 1-79, View A. Step 3Place the two remote power-cycling control wires (18 AWG maximum) in the ferrite bead...
Page 310
1-102 Catalyst 6500 Series Switches Installation Guide OL-5781-08 Chapter 1 Removal and Replacement Procedures Installing the Remote Power Cycling Feature Control Wires (Optional)