Page 101
5-13 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting Troubleshooting Supervisor Engines In order to determine whether the standby supervisor engine is faulty, enter the redundancy reload peer command from the active supervisor engine and through the console to the standby supervisor engine. Observe the bootup sequence in order to identify any hardware failures. Currently, the active supervisor engine cannot access the power-on diagnostics results of the...
Page 102
5-14 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting Troubleshooting Supervisor Engines are functional. When dual supervisor engines are present, only ports n/1 and n+1/1 are functional and n/2 andn+1/2 are not functional. For more information, refer to the redundancy chapter in the software configuration guide. Packet Loss If your system exhibits partial or full loss of network connectivity or packet loss, perform basic troubleshooting procedures to...
Page 103
5-15 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting Troubleshooting Supervisor Engines 1d21h: %SYS-5-RELOAD: Reload requested Decompressing the image : ################################################### #################################[OK] k2diags version 1.6 prod: WS-X4014 part: 73-6854-09 serial: JAB0620090U Power-on-self-test for Module 1: WS-X4014 Status: (. = Pass, F = Fail) Traffic using serdes loopback (L2; one port at a time)......
Page 104
5-16 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting Troubleshooting Supervisor Engines St e p 2Enter the show diagnostics power-on command to verify the POST results from bootup and determine if diagnostics fail again. If diagnostics fail again, the problem is most likely hardware. Contact Cisco Technical Support for further assistance. If the supervisor engine passes the diagnostic tests without any failure after the power cycle in Step 4, perform...
Page 105
5-17 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting Troubleshooting Supervisor Engines Interface Problems If you see an error mentioned in the output of the show interface command, the reason could be: •A physical layer problem, such as a faulty cable or NIC •A configuration problem, such as a speed and duplex mismatch •A performance problem, such as an oversubscription In order to understand and troubleshoot these problems, refer to Troubleshooting...
Page 106
5-18 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting Troubleshooting Supervisor Engines If you still have issues after you review and follow the procedure in the document Troubleshooting Cisco Catalyst Switches to NIC Compatibility Issues, contact Cisco Technical Support for further assistance. Interface Is in Errdisable If the interface status is err-disable in the output of the show interface status command, some possible reasons include: •Duplex...
Page 107
5-19 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting Troubleshooting Supervisor Engines The supervisor engines have onboard system Flash memory (bootflash), which should easily hold multiple system images. Therefore, have a backup image. In addition to the bootflash, the supervisor engine supports up to 128 MB of compact Flash in the slot0: device. The supervisor engine also provides for transfer via TFTP of the image from ROMmon mode, which enables...
Page 108
5-20 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Chapter 5 Troubleshooting Contacting the Cisco Technical Assistance Center St e p 13If the connected device is an end station: a.Enable spanning-tree PortFast on the port (use the set spantree portfast enable command)—PortFast places the port in forwarding mode immediately, bypassing listening and learning modes (do not use this feature for connections to non-end station devices). b.Disable trunking on the port (use the set...
Page 109
A-1 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 APPENDIXA Power Supply Specifications Revised: March 2013 This appendix describes the power supplies supported by the Catalyst 4500 E-series switches. The appendix contains the following sections: •1000 W AC-Input Power Supply, page A-2 •1300 W AC-Input Power Supply, page A-6 •1400 W AC-Input Power Supply, page A-10 •1400 W DC-Input Power Supply, page A-15 •1400 W Triple-Input DC-Input Power Supply, page A-19 •2800 W AC-Input Power...
Page 110
A-2 Catalyst 4500 E-Series Switches Installation Guide OL-13972-02 Appendix A Power Supply Specifications 1000 W AC-Input Power Supply 1000 W AC-Input Power Supply The 1000 W AC-input power supply (PWR-C45-1000AC), shown in Figure A-1, is supported in the following Catalyst 4500 E-Series switches: •Catalyst 4503-E •Catalyst 4506-E •Catalyst 4507R-E •Catalyst 4507R+E •Catalyst 4510R-E (the 1000 W AC-input power supply can be installed in the Catalyst 4510R-E switch chassis; however power...