Page 11
J Series Serial Commands Technical Reference Information11 of 90020-100796-01 Rev. 1 (10-2011) (ILV) ILS Settings Valid (MDE) Serial Mode (PMT) Picture Mute (INM) Channel ‘In Menu’ (MFT) Menu Font (PNG) Ping (ITG) Test Pattern Grey (MLK) Channel Memory Lock (PPA) Position Preset Aspect (ITP) Internal Test Pattern (MNR) Mosquito Noise Reduction (PPP) PIP Position Preset (KEN) Keypad IR Sensor Disable (MNU) Menu Settings and Config- uration (PPS) PIP Swap (KEY) Key Mode Emulation (MSH) Menu...
Page 12
12 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (SPS) Splash Screen (TDM) 3D Mode (TTM) THIC Transmitter Mode Configuration (SPT) Split Screen (TDN) Invert 3D Input (TXE) Texture Enhancement (SST) System Status (TDO) 3D Sync Out (UID) User ID (STD) Video Standard (TDT) 3D Test Pattern (VBL) Video Black Input (SZP) Size Presets (TED) Twin HDMI EDID type selection (VRT) Vertical Position (TBL) Top Blanking (TIL) Tiling Control (VST) Vertical...
Page 13
J Series Serial Commands Technical Reference Information13 of 90020-100796-01 Rev. 1 (10-2011) DETAILED SERIAL COMMAND DESCRIPTIONS (ACE) AUTO COLOR ENABLE CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Automatically select Color Enable based on the control being adjusted. If enabled, this control allows the projec- tor to automatically change the color enable control when the user is using the OSD interface to adjust controls such as input levels, odd...
Page 14
14 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (ACT) Active Window con’t EXAMPLES: (ACT?) - Returns the active window for main video. (ACT+PIIP?) - Returns the active window for PIP video. (ACT+IN12?) - Returns the active window for slot 1 input 2. (ADR) ADDRESS CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Set/Query Device Address on ASCII Protocol network. Required only for RS232 connections that are...
Page 15
J Series Serial Commands Technical Reference Information15 of 90020-100796-01 Rev. 1 (10-2011) (AIC) AUTO INPUT CYCLING CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION When enabled, the system will continually search for the next valid signal when no signal is present or when loss of sync occurs on the current user selected input. In the case of multiple signals to choose from, the order is based on slot, followed by inputs on that slot. SUBCODE...
Page 16
16 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (ALT) Active Loop-Through con’t EXAMPLES: (ALT 1) - Enable Standby active loop-through. (ALT 0) - Disable Standby active loop-through. (ALT?) - Get the current Standby active loop-through setting. (APR) APERTURE CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION The Optical Aperture control sets the diameter of the light path. It is used to trade off between contrast and...
Page 17
J Series Serial Commands Technical Reference Information17 of 90020-100796-01 Rev. 1 (10-2011) (APW) Auto Power Up con’t EXAMPLES: (APW 0) - Projector will remain in Standby Mode until the user presses the power key. (APW 1) - Projector will auto power up when A/C power is switched on if it was in a powered on state (i.e. not in standby mode) when the A/C power was powered off in the previous power cycle. (ARO) ASPECT RATIO OVERLAY CONTROL GROUP: Unsaved SUBCLASS: Power Up ACCESS LEVEL:...
Page 18
18 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (ASR) AUTO CHANNEL SELECT CONTROL GROUP: Channel SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION The Auto Channel Select option allows the projector to select the channel memory best suited to the input signal. If the current channel does not allow Auto Channel Select, the projector will not attempt to select a new channel when the signal changes. If the current channel does allow Auto...
Page 19
J Series Serial Commands Technical Reference Information19 of 90020-100796-01 Rev. 1 (10-2011) (ASU) Auto Setup con’t PIIP or SECD Perform a standard auto setup on the picture in picture or Second- ary video. FRZE Hides temporary image artifacts that may appear during the auto setup procedure. EXAMPLES: (ASU) - Perform standard auto setup on main video. (ASU+FRZE 1) - Freeze image during auto setup. (ASU+FRZE 0) - Disable image freezing during auto setup. (ASU+MAIN) - Perform standard auto setup on...
Page 20
20 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (BDR) BAUD RATE CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Advanced DESCRIPTION Set the baud rate for a serial communications port. For RS232 IN and RS232 OUT, the default is 115200. For RS422, the default is 19200. The default communications settings for all ports is 8 data bits, no parity. Valid baud rates, with the values to select them, are: 0 = 1200 1 = 2400 2 = 9600...