9LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) ƒ „ˆ ‰ Š ‹ ‡†… CD (1) (1) µ RD(2) (2) RD TD (3) (3) TD DTR (4) (4) µ GND (5) (5) GND DSR (6) (6) µ RTS (7) (7) RTS DTS (8) (8) CTS RI (9) (9) µ RS-232C Communication RS-232C Communication When the projector connects to the computer by RS-232C communication, the projector can be controlled with RS-232C commands from the computer. For details of RS-232C commands, refer to RS-232C Communication /...
Page 12
10LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) RS-232C Communication (continued) Communicaion settings 1. Protocol 19200bps, 8N1 2. Command format ("h" shows hexadecimal) Byte Number01 2 3456789101112 Command ActionHeader Data Header code Packet Data sizeCRC flagAction TypeSetting code LH LHLHLHLHLH Change setting to desired value [(cL)(cH)] by [(bL)(bH)]. BEh EFh 03h 06h 00h(aL) (aH) 01h 00h (bL) (bH) (cL) (cH) Read projector internal setup value [(bL) (bH)] .(aL)...
Page 13
11LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) RS-232C Communication (continued) 3. Response code / Error code ("h" shows hexadecimal) (1) ACK reply: 06h When the projector receives the Set, Increment, Decrement or Execute command correctly, the projector changes the setting data for the specified item by [Type], and it returns the code. (2) NAK reply: 15h When the projector cannot understand the received command, the projector returns the error code. In such a...
Page 14
12LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) When the projector connects network, the projector can be controlled with RS- 232C commands from the computer with web browser. For details of RS-232C commands, refer to RS-232C Communication / Network command table (18). Command Control via the Network LAN USB wireless adapter LAN cable (CAT-5 or greater) Connection 1. Turn off the projector and the computer. 2. If you use wired LAN, connect the projector's LAN port to...
Page 15
13LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) Communicaion Port The following two ports are assigned for the command control. TCP #23 TCP #9715 Configure the following items form a web browser when command control is used. Port Settings Network Control Port1 (Port: 23)Port openClick the [Enable] check box to open [Network Control Port1 (Port: 23)] to use TCP #23. Default setting is “Enable”. AuthenticationClick the [Enable] check box for the [Authentication] setting when...
Page 16
14LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) Command control settings [TCP #23] 1. Command format Same as RS-232C communication, refer to RS-232C Communicaton command format. 2. Response code / Error code ("h" shows hexadecimal) Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4). One authentication error reply (5) is added. (1) ACK reply : 06h Refer to RS-232C communication (11). (2) NAK reply : 15h Refer to RS-232C...
Page 17
15LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) NOTE • As for the transmission of the second or subsequent commands, the authentication data can be omitted when the same connection. 2. Response code / Error code ("h" shows hexadecimal) The connection ID is attached for the TCP#23's response / error codes are used. The connection ID is same as the sending command format. (1) ACK reply: 06h + ××h (××h : connection ID) (2) NAK reply: 15h + ××h (3) Error reply:...
Page 18
16LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) This projector is equipped with NETWORK BRIDGE function. When the projector connects to the computer by wired or wireles LAN communicaton, an external device that is connected with this projector by RS- 232C communication can be controlled from the computer as a network terminal. For details, see the 6. Network Bridge function in the Network Guide. Network Bridge Communication LAN LAN cable (CAT-5 or greater) RS-232C RS-232C...
Page 19
17LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) Communication settings For communication setting, use the COMMUNICATION menu in the OPTION - SERVICE menu Item Condition BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps Data length 8 bit (fixed) PARITY NONE/ODD/EVEN Start bit 1 bit (fixed) Stop bit 1 bit (fixed) Transmission method HALF-DUPLEX/FULL-DUPLEX NOTE • For connecting the projector to your devices, please read the manual for each devices, and connect them correctly with...
Page 20
18LX501/LX601i User Manual-Technical Guide 020-000503-01 Rev. 1 (03-2012) RS-232C Communication / Network command table RS-232C Communication / Network command table (continued on next page) Names Operation Type HeaderCRCCommand DataAction Type Setting code Power SetTurn off BE EF 03 06 00 2A D3 01 00 00 60 00 00 Turn on BE EF 03 06 00 BA D2 01 00 00 60 01 00 GetBE EF 03 06 00 19 D3 02 00 00 60 00 00 [Example return] 00 00 01 00 02 00 [Off] [On] [Cool down] Input...