Home > Christie > Projector > Christie Projector LWU701i User Manual

Christie Projector LWU701i User Manual

Here you can view all the pages of manual Christie Projector LWU701i User Manual. The Christie manuals for Projector are available online for free. You can easily download all the documents as PDF.

Page 31

30LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
30° 30°
3m
30°30°30°30°30°30°30°30°30°30°30°3m
(approx.)
About the remote control signal
The remote control works with 
the projector’s remote sensor. 
This projector has two remote 
sensors on the front and back 
sides.
The sensors can sense signals 
within the following range:
60 degrees (30 degrees to the 
left and right of the sensor) 
within about 3 meters.
• You can deactivate one of the sensors...

Page 32

31LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
  In a normal state  
The Status Monitor displays the state of the projector in 
three lines.
:  Displays the condition of the projector. While the lamp is on, the selected port is 
displayed.
Displayed conditions are as below;
STANDBY: The projector is in standby mode.
WARM UP: The projector is warming up.
SEARCHING: The projector is searching an input signal.
COOL DOWN:  The projector is cooling...

Page 33

32LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
Displaying the condition of the projector (continued)
• While the projector is searching an input signal in normal condition, 
nothing is displayed on the 2nd line of the monitor.
• Displayed temperature might differ from actual peripheral temperature 
because the displayed temperature is measured inside of the projector. NOTE
Status Monitor 
  In error state 
The Status Monitor displays a warning of...

Page 34

33LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
Status  Monitor  
When the projector is in a normal condition, 
or displays one of the warnings of AIR FLOW, 
COLD or FILTER errors, press the FUNCTION 
button on the control panel, press the ENTER 
button on the remote control for three seconds 
or press one of the MY BUTTON buttons if 
assigned as STATUS MONITOR. The backlight 
of the monitor turns on.
  To display the setup information including...

Page 35

34LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
AC240V35°C
7FILTERERRO
1PREVIOUS
   To display error history 
Press the ▲ button to display the previous 
error log. If a warning has been displayed, 
the first previous error log is the present 
error currently occurring. The Status Monitor 
displays the log number, occurred error, the 
supplied voltage and peripheral temperature 
at that time. Press the ► button to display the 
usage time when each...

Page 36

35LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
1.Make sure that the power cord is firmly 
and correctly connected to the projector 
and the outlet.
Turning on the power
2.Make sure that the POWER indicator is 
lighted in steady orange (
11 7 ). Then 
remove the lens cover.
3.Press STANDBY/ON button on the projector  
or the ON button on the remote control.
The projection lamp lights up and the  POWER indicator begins blinking in 
green. When the...

Page 37

36LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
►A strong light is emitted when the projector’s power is on.  
Do not look into the lens of the projector or look inside of the projector through 
any of the projector’s openings as the projection ray may cause a trouble on your 
eyes.
►Keep objects away from concentrated projection light beam. Blocking the 
beam by something causes high temperature and could result in fire or smoke.
►Do not touch...

Page 38

37LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
Operating
Operating
1.
Adjusting the volume
Use the VOL + / - buttons to adjust the volume. 
A dialog appears on the screen to help you in adjusting 
the volume. If you do nothing, the dialog automatically 
disappears after a few seconds.
• 
When  is selected for current picture input port, the volume 
adjustment is disabled. See AUDIO SOURCE item of AUDIO menu (
80).
• If the projector is in the...

Page 39

38LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
Operating
1.Press INPUT button on the projector. 
When you press the button, the projector switches 
its input port from the current port as below.
Selecting an input signal
1.
INPUT button
SHUTTER           LAN    COMPUTER IN    HDMI 1
         VIDEO                                      HDMI 2
           SDI*       HDBaseT      DisplayPort 
Buttons for input 
ports
• If you have set SKIP to some...

Page 40

39LWU701i/LW751i/LX801i/LWU601i/LW651i
User's Manual - Operating Guide020-000786-02
LIT MAN USR D2
Operating
Selecting an aspect ratio
1.Press the ASPECT button on the remote control.   
Each time you press the button, the projector switches 
the mode for aspect ratio in sequence. 
ASPECT 
button
• The ASPECT button does not work when no proper signal is input.
• NORMAL mode keeps the original aspect ratio setting. NOTE
  For a computer signal 
LX801i:  
  NORMAL  4:3  16:9  16:10...
Start reading Christie Projector LWU701i User Manual

Related Manuals for Christie Projector LWU701i User Manual

All Christie manuals