Page 91
Section 3: Operation User’s Manual 3-69. Table 3.5 Error Codes Code Description GENERAL 12 Software bug. Contact dealer/factory. 13 CRC error in flash ROM. Download new software. 14 Engineering-only programming is complete. Call Christie, replace TIPM. 15 Attempting to download code without being in boot mode 16 Invalid interrupt. Power off/on. If it persists, contact dealer/factory. 17 User forced system to stay in boot mode 18 Jumper for programming boot not installed LAMP...
Page 93
Section 4 Maintenance User’s Manual 4-1 The projector is an international regulatory agency approved product designed for safe and reliable operation. To assure complete safety at all times it is important to acknowledge the following precautions while operating the projector. WARNING Always remove the lens when shipping the projector. WARNING NEVER look directly into the projector lens. The high brightness of this projector could cause permanent eye damage. WARNING For...
Page 94
Section 4: Maintenance 4-2 User’s Manual ◊ Only use Christie-approved ceiling mount fixture, if the projector is to be ceiling mounted. Lamp: The projector uses a Cermax Xenon lamp to deliver its high brightness. A lamp should be replaced when it has reached its end of life (1000 hrs, typical) or if a noticeable change in brightness occurs. Keep track of the number of hours the lamp has been in use (Lamp Menu) and be aware of any changes to brightness. These indicators will help you...
Page 95
Section 4: Maintenance User’s Manual 4-3. Slots and vents in the projector provide ventilation. Never block or cover these openings. This ensures reliable operation of the projector and prevents overheating. ◊ Do not place the projector over a radiator or heat register. The projector should not be placed in an enclosure unless proper ventilation is provided. ◊ Do not insert objects into the ventilation openings of the projector. They may touch dangerous voltages or short-out components...
Page 96
Section 4: Maintenance 4-4 User’s Manual WARNING Always power down and unplug the projector before cleaning or servicing. Table 4.1. Maintenance Guide Part Description Frequency Action Lens As required CLEAN: Clean if absolutely necessary. A small amount of dust on the lens has very little affect on picture quality. To clean: Apply a solvent such as acetone, alcohol or vinegar sparingly to clean, lint- free lens tissue. Wipe across the surface of the lens. Do not scrub or rub...
Page 97
Section 4: Maintenance User’s Manual 4-5. The optional IR remote uses two AA size, 1.5V alkaline batteries. To replace the batteries simply turn the remote over and push out the cover using the finger groove, as shown in (1) Figure 4.1. Remove and properly discard the old batteries. Insert new batteries in the proper positive/negative orientation as shown etched in the bottom of the compartment (2). Replace the cover by inserting the tabbed end into the opening and snapping the...
Page 98
Section 4: Maintenance 4-6 User’s Manual WARNING Handle lamp with care. Lamp may explode if dropped. Wear protective clothing and safety goggles when handling lamps. Use only Christie approved lamps provided in Lamp and Filter Service Kits for your projector. 1. Press to power down the projector. Wait at least 5 minutes to allow the internal cooling fans to stop before unplugging the projector. This wait period is also required to allow the lamp to sufficiently cool before...
Page 99
Section 4: Maintenance User’s Manual 4-7. Figure 4.4. 5. Align the new lamp with the top and bottom guides on the left side of the lamp compartment. (Figure 4.5.) Slide the lamp all the way in – a slightly harder push may be required right at the end to make sure it is fully seated into the terminal block. NOTE: The projector will not power up again if the lamp is not fully connected to the terminal block. Figure 4.5. 6. Pull (out) and turn the lamp lock lever (turned up in...
Page 100
Section 4: Maintenance 4-8 User’s Manual The two filters located at the front and left side of the projector should be replaced whenever the lamp is replaced. If you are working in an extremely dusty environment you may want to replace the filters sooner. Use the filters provided in the Christie approved Lamp and Filter Kit for your specific projector model (Table 1.) Tools required: #1 Phillips screwdriver 1. Loosen the screw(s) from the filter access panels. The front...