    UTILITY SETUP
    This section is only applicable if your utility company is running a demand
    response or price response program in which you have agreed to participate.
    Contact your local electrical utility company for information about programs in
    your area.
    NOTE:If you do want to participate with your electrical utility company, a service
    person must enable the utility event interface.
    A14262
    Utility Event
    Your utility may send price response or demand response events to your Wi--Fi
    enabled Infinity Touch Control. When a price response or demand response event is
    received, your temperature set points will be automatically adjusted depending on
    the utility event setup settings that you have selected.
    When a utility event is in progress…
    SThe temperature set points will be automatically adjusted depending on
    the utility event setup. The adjusted heating and cooling temperatures
    will be displayed in green on the main screen along with a “utility
    event” message.
    SA utility event icon will appear on the home screen. Pressing the icon or
    manually adjusting the heating and cooling set points will display the 
    						
    							56 type of event, the adjustment to the heating and cooling set points, the
    time the event will end, an accept button, and an override button.
    SPressing the accept button will accept the adjustments made to the heat-
    ing and cooling set points.
    SPressing the override button will change the heating and cooling set
    points back to their original values prior to the event.
    Price Response
    Price response determines how the heating and cooling set points will be adjusted
    during a pricing event with two choices -- offsets or absolute temperature. When
    offsets are selected, the heating and cooling set points are adjusted by the number of
    degrees selected. When absolute temperature is selected, the heating and cooling
    set points are adjusted to heating and cooling temperatures.
    A14263
    Price Settings
    When the electric rate from the utility company meets or exceeds the
    “ELECTRICAL RATE”, the heating and cooling set points will be adjusted
    according to the absolute temperature or offset shown here. If the set point at the
    time of the event is more favorable (uses less energy) than what you have
    programmed, the Infinity Touch Control Thermostat will use the more favorable set
    point for the duration of the event. 
    						
    							57
    A14264
    Demand Response
    Demand response determines how the heating and cooling set points will be
    adjusted during a demand response event with two choices -- offsets or absolute
    temperature. When offsets are selected, the heating and cooling set points are
    adjusted by the number of degrees selected. When absolute temperature is selected,
    the heating and cooling set points are adjusted to heating and cooling temperatures.
    A14265 
    						
    							58
    Demand settings
    When a demand response is received from the utility company, the heating and
    cooling set points will be adjusted according to the absolute temperature or offset
    shown here. If the set point at the time of the event is more favorable (uses less
    energy) than what you have programmed, the Infinity Touch Control Thermostat
    will use the more favorable set point for the duration of the event.
    A14266
    Response Limits
    Response limits are minimum heating and maximum cooling temperatures allowed
    during a utility event. These limits are not exceeded and are intended to protect the
    occupant premises from extreme temperatures that might otherwise be imposed by
    a utility event.
    A14267 
    						
    							59
    Restore UE factory Default Settings
    Restore UE (Utility Event) factory default settings will restore all utility event set
    points and price settings to their original factory default values.
    A14268 
    						
    							Infinity, Touch ’N’ Gotand HYBRIDHEATRare trademarks or registered
    trademarks of Carrier Corporation in the United States and other countries. Other
    brands and product names are trademarks of their respective holders.
    U.S. Export Classification: EAR99.
    Version 11 Software Release
    Copyright 2014 Carrier Corp.S7310 W. Morris St.SIndianapolis, IN 46231
    Edition Date: 03/14 997-011290-7-R
    Manufacturer reserves the right to change, at any time, specifications
    and designs without notice and without obligations.Replaces: OMSYSTXCCITW --- 06
    Catalog No: OMSYSTXCCITW --- 07 
    						
    All Carrier manuals Comments (0)