Page 11
8 6. SPLIT SYSTEM DESCRIPTION 1: Remote control signal receiver. 2: Operating status leds. 6: Supply air outlet 3: Supply air flap 7: Characteristics nameplate. 4: Air return. 8: Inter connecting tubing. 5: Air filter. 9: Condensate drain line. Indoor Unit 38 7 2 1 9 4 5 Outdoor Unit 6
Page 12
9 7. INSTALLATION ACCESSORIES 7.1 STANDARD INSTALLATION ACCESSORIES Supplied from the factory DESCREPTION CONFIGURATION QTY USAGE Battery 1.5 volt size AAA alkaline type 2 To operate the wireless remote control Wireless remote control and Plastic holder for remote 1 To operate the air conditioner To mount remote control on the wall Owner manual 1 To illustrate control functions of operation Installation Manual 1 To illustrate installation instructions. Insulation Tube. 1 To...
Page 13
10 INSTALLATION ACCESSORIES (Cont.) 7.4 OTHER INSTALLATION ACCESSORIES Not supplied from the factory but must be used in the field to complete installation. DESCREPTION USAGE Electrical Connection Cords To electrically connect the indoor unit, the outdoor unit and circuit breaker ـ Wall Sleeve ـ Wall Cap ـ Sealer putty To fill the gap between the wall hole and the lump of refrigerant piping lines, electrical connection cables and condensate drain line. ـ Finishing tape PVC...
Page 14
11 8. INSTALLATION CHART 1) Installing outdoor unit 5) Connecting refrigerant piping lines 9) Air purging with a vacuum pump 2) Drilling hole thru the wall 6) Connecting condensate drain line 10) Refrigerant leak test 3) Installing indoor unit 7) Connecting electrical wiring 11) Opening service valves 4) Processing pipes 8) Finishing outer pipe covering 12) Finishing installation 13) Test Running 14) Description of operation Outdoor unit
Page 15
12 9. SELECTING INSTALLATION LOCATION FOR INDOOR UNIT 9.1 CONSIDERATIONS FOR SELECTING INSTALLATION LOCATION Avoid excessive height difference between indoor and outdoor units Avoid excessive length of refrigerant piping lines between indoor and outdoor units Location of Indoor Unit Relative to Space to be Air-Conditioned. The installation location should permit the unit to deliver air to all of the space to be uniformly air-conditioned. Avoid direct sunlight that may affect...
Page 16
13 SELECTING INSTALLATION LOCATION FOR INDOOR UNIT (Cont.) CONSIDERATIONS FOR SELECTING INSTALLATION LOCATION (Cont.) Avoid an installation location, which has an environment with oil vapors. Avoid an installation location which has an environment affected by high frequency waves generated as from radio equipment’s welders and medical equipment’s. Avoid installation location on humid walls or positions with water hazard, e.g. laundry premises. Check that the wall surface is flat...
Page 17
14 SELECTING INSTALLATION LOCATION FOR INDOOR UNIT (Cont.) 9.2 POSSIBLE OUTLET LOCATIONS OF REFRIGERANT PIPING LINES FROM INDOOR UNIT Possible outlet locations of refrigerant piping lines from indoor unit. The refrigerant piping lines can be connected in one of the following Four outlet locations as indicated by (1), (2), (3) and (4) When the piping is connected to the direction of (1) or (2) or (4), Detach the knock – out either at the side or at the bottom of the unit. See...
Page 18
15 10. SELECTING INSTALLATION LOCATION FOR OUTDOOR UNIT 10.1 INSTALLATION LOCATIONS The condensing unit can be installed in any outside location, on a wall, roof or on a ground level. 10.2 CONSIDERATIONS FOR SELECTING INSTALLATION LOCATIONS Avoid excessive distance between outdoor and indoor units Avoid excessive height between outdoor and indoor units Avoid any obstruction of the unit air outlet and intake or any obstacle that is too close Avoid multiple unit...
Page 19
16 SELECTING INSTALLATION LOCATION FOR OUTDOOR UNIT (Cont.) CONSIDERATIONS FOR SELECTING INSTALLATION LOCATION (Cont.) Avoid dripping into passageways. Avoid soiling of pipe ends Avoid allowing piping to get wet before connection Avoid disconnecting the refrigerant connections after installation, this will cause refrigerant leaks Avoid connecting the condensate drain line to the outdoor unit. a. Weight of Outdoor Unit The installation location of outdoor unit should...
Page 20
17 11. INSTALLATION LOCATION CHECK LIST (A) INDOOR UNIT - The installation location is close to the outdoor unit - The wall hole (required to pass refrigerant piping, electrical cables and drain line) is on the unit right back - The installation location permit the unit to deliver air to all of the space to be air-conditioned - The installation location is far away from any sunlight - The installation location is far away from any heat sources - The installation...