Carrier 42qg24-h Manual
Here you can view all the pages of manual Carrier 42qg24-h Manual. The Carrier manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 41
38 CONNECTING ELECTRICAL WIRING (Cont.) 17-3 ELECTRICAL DATA Input Power Main Power Connections Cooling Split System Model Starting Current (Note 1) System Power Supply 35 °C * 46 °C ** 52 °C *** Heating **** Circuit Breaker Wire Size (Note 2) Heat Pump Amp V/Ph/Hz Amp Watt Amp Watt Amp Watt Amp Watt Amp mm² Standard mild ambient outdoor unit with rotary compressor 53QG18-H 52 9.5 1945 11.5 2425 - - 805 1745 20 4 53QG24-H 78 220/1/50 11.8 2435 13.9 2880 15.1 3130 11.8...
Page 42
39 LEGEND Earth L Live power supply. N Neutral power supply. R Live connection indoor/outdoor unit. C Neutral connection indoor/outdoor unit. Y Compressor control. O Reversing valve control. W2 Outdoor fan motor control. S Outdoor coil sensor. LEGEND Earth L Live power supply. N Neutral power supply. R Live connection indoor/outdoor unit. C Neutral connection indoor/outdoor unit. Y Compressor control. CONNECTING ELECTRICAL...
Page 43
40 Piping Decorative Tape Saddles 18. FINISHING INSTALLATION 18-1 FINISHING STEPS FOR INSTALLATION d. Insert grille frame to the top of the indoor unit body. a. Tie together refrigerant piping, drain hose, electrical connection cords. Form the refrigerant piping in the required direction and bind the drain hose, electrical connection cord and signal line together with vinyl tape. • The drain hose should be always at the bottom of lump to assure smooth drainage. • The lump...
Page 44
41 19. TEST RUNNING 19.1 Note: - Operate test running after mounting air filters, return grill and cabinet. - Operate testing running after completion of connecting refrigerant piping lines, drain line and electrical wiring 19.2 STEPS FOR COOLING TEST RUNNING a. Move circuit breaker to ON position. b. After system operation becomes stabilized: - Measure high and low pressures to check correct refrigerant charge. (See figure & table) - Measure total Amps consumed by the...
Page 45
42 TEST RUNNING (Cont.) 19.4 STEPS FOR HEATING TEST RUNNING a. Move circuit breaker to ON position. b. After system operation becomes stabilized: - Measure high and low pressures to check correct refrigerant charge. (See figure) - Measure total Amps consumed by the system. - Measure system-working voltage. System Heating Test Running SYSTEM MODEL 53QG18-H 53QG24-H AMBIENT TEMP ºC 7 7 HIGH PRESSURE PSI 240 260 LOW PRESSURE PSI 52 50 TOTAL AMPS...
Page 46
43 20. AIR CIRCULATION FOR INDOOR UNIT 42QG SERIES Air is supplied into the room through the supply grilles located on the bottom of the cabinet of the indoor unit. Air from the room is drawn into the indoor unit through the return grille and filters at the top of the indoor unit. • Make absolutely sure that the supply and return grilles of the indoor units are not obstructed (even partially). The airflow direction can be adjusted to optimize air distribution in the room. Press button SWING...
Page 47
44 21. AFTER INSTALLATION CHECK LIST 21.1 INDOOR UNIT a. The installation location is adequate. b. The unit is solidly mounted and leveled. c. The air filters are installed correctly. d. The internal deflectors of supply air are adjusted for correct air diffusion. 21.2 OUTDOOR UNIT a. The installation location is adequate. b. The unit is solidly mounted and leveled. c. The wall support is fixed properly with the wall. d. The service door and its fixing screw are...
Page 48
45 INSTALLATION CHECK LIST (Cont.) 21.6 FINISHING INSTALLATION a. The refrigerant piping lines, electrical cables and drain hose are lumped together. The drain hose is at the bottom of lump. b. The wall passage hole is properly sealed. 21.7 TESTING RUNNING a. The cooling and heating cycles are tested At least one complete cooling cycle of unit operation is observed. At least one complete heating cycle of unit operation is observed. b. There is no any abnormal noise or...
Page 49
46 22. INSTALLATION OF OPTIONAL AIR FILTERS 22.1 NOTE: Optional set of air filters can be added and field installed as shown below. 22.2 TYPE OF AIR FILTERS: Standard anti – bacteria air filters for dust & bacteria removal Optional carbon filter for odor removal Optional photo-catalytic filter for cigarette smoke removal 22.3 INSTALLATION STEPS OF OPTIONAL AIR FILTERS: Step (1): After lifting return air grill up to the top of the unit, pull the standard air filters...
Page 50
47 23. SELF DIAGNOSTIC FUNCTION FOR MALFUNCTIONS DETECTION EXPLAINATION OF SELF-DIAGNOSTIC FUNCTION - Self-diagnostic function is the key for success of air conditioner operation. - The printed circuit boards existing inside the indoor unit are equipped with self-diagnostic function to detect malfunction and automatically stops the operation at the air conditioner. - Once a malfunction is detected, the diagnostic control section will force the system mode to OFF for 3 minutes....