Page 111

Chapter 7  ISIS/TWAIN Driver Settings
7-12
Scan Area Dialog Box (TWAIN Driver)
This dialog box appears with application programs that display the [Scan] button in the Properties 
dialog box.
 
The Area window and [Preview] button are not displayed when using applications like the Job 
Registration Tool that display the [OK] button in the Properties dialog box.
 
Page Size
This setting is linked to the [Page Size] setting, for selecting the size of document pages to scan.
☞Clicking the [Custom] button...

Page 112

Chapter 7  ISIS/TWAIN Driver Settings
7-13
☞ When [Deskew] is enabled on the [Basic] tab sheet, the specified area may be displaced when 
scanning.
Area Window
The size indicated for the Area window corresponds to the page size setting, and the area within the 
panel indicates the current scanning area. 
☞The scanning area can be adjusted by dragging the handles   bordering the Area window with 
your mouse.
☞With CapturePerfect, the last scanned image appears in the Area window.
Margin
This control...

Page 113

Chapter 7  ISIS/TWAIN Driver Settings
7-14
The availability of brightness and contrast settings are as follows according to the mode setting on 
the [Basic] tab sheet.
✓: Available for setting
— : Not available for setting, or automatically set
[Auto] Check Box
This check box is enabled when the scanning mode is [Black and White], and selecting it adjusts 
brightness and contrast to match the document.
Brightness
Adjusts the brightness of images to be scanned.
☞If images are too dark or if text on the...

Page 114

Chapter 7  ISIS/TWAIN Driver Settings
7-15
[Gamma Settings] Dialog Box
Use the [Gamma Settings] dialog box to adjust the gamma correction value.
 
[Custom] Check Box
Select this check box to set custom gamma correction.
☞When [Custom] gamma setting is selected, all settings on the [Brightness] tab sheet are made 
automatically.
Select
Select the side and color for custom setting.
 
☞The color bar and color of the sample image are changed to show the specified color.
Input method
Select the setting method...

Page 115

Chapter 7  ISIS/TWAIN Driver Settings
7-16
☞You can also move the gamma curve by dragging it with the mouse.
 
[Freehand]
The output value for a particular input value in the gamma table can be specified with the mouse.
☞Click any point in the Gamma Curve Graph to set that point as an output value.
☞Drag the mouse on the Gamma Curve Graph to set the output value according to the mouse 
movement.
[Import] Button
Clicking this button loads gamma table data (*.png file) that was previously stored with the...

Page 116

Chapter 7  ISIS/TWAIN Driver Settings
7-17
[Image processing] Tab Sheet
The [Image processing] tab sheet provides settings affecting processing of scanned images. Some 
settings may be disabled depending on the mode settings on the [Basic] tab sheet. Refer to “Mode-
Dependent Function Limitations,” on p. 7-7 for details.
 
[Edge Emphasis]
Adjusts image contours. Move the slider toward Soft to soften image contours, or toward Sharp to 
sharpen image contours.
[Document Orientation]
This setting selects an...

Page 117

Chapter 7  ISIS/TWAIN Driver Settings
7-18
[Text Orientation Recognition] Check Box
Select this check box to detect text orientation in scanned images, and rotate images in 90º 
increments as needed to normalize orientation.
☞When [Text Orientation Recognition] is selected, [Image Rotation] and  area settings in the Scan 
Area dialog box are disabled.
☞Some application programs do not support [Text Orientation Recognition]. Please disable [Text 
Orientation Recognition] if your application program...

Page 118

Chapter 7  ISIS/TWAIN Driver Settings
7-19
 
☞The color range within the shaded (cross-hatched) area is dropped out or enhanced.
☞You can move the shaded area by dragging with the mouse.
☞You can change the specified color range by dragging the edges of the shaded area. 
☞Because your operating environment affects the colors you specify on screen, they may not 
match those actually dropped out or enhanced: that is, the colors you specify may not match 
those processed.
[Others] Tab Sheet
The settings on...

Page 119

Chapter 7  ISIS/TWAIN Driver Settings
7-20
[Others] Tab Sheet (TWAIN driver)
[Reverse side]
Scanning occurs as follows depending on the scanning side settings.
☞When this check box is selected and the scanning side is set to [Simplex], only the back of each 
page is scanned.
☞When this check box is selected and the scanning side is set to [Duplex] or [Skip Blank Page],  the 
back of each page is scanned first, followed by the front.
[Rapid Recovery System] Check Box
If a paper jam causes paper transport...

Page 120

Chapter 7  ISIS/TWAIN Driver Settings
7-21
Double Feed Detection
This function stops document transport when double feeding of document pages is detected, and 
provides selection of the detection method to suit the documents to be scanned.
[Detect by Length]
This method of double feed detection is good for batch scanning of same-size documents: the length 
of the first document page fed is taken as a standard, and when a subsequent document is detected 
to be 50 mm longer (or shorter) than the standard,...
Start reading Canon scanner imageFORMULA DR6010C User Manual

Related Manuals for Canon scanner imageFORMULA DR6010C User Manual

All Canon manuals