Page 21
21 Replacing the light bulb 1.Switch off the extractor hood and pull out the mains plug or switch off the electricity supply at the fuse box. 2.Pull out the filter drawer all the way. 3.Pull the lamp cover forwards. 4.Replace the light bulbs. (Standard candle bulbs, max. 60 W, E14 socket). 5.Re-insert the lamp cover. 6.Plug appliance into mains again or switch on at the fuse box. Cleaning and care Disconnect the extractor hood from the electricity supply by pulling out the mains plug or switching it...
Page 22
22 Important information Installation Instructions: The installation of the extractor hood above gas cooking devices, at a minimum height of650 mm – Fig. 1 – is permitted provided that the following nominal heat loads (Hs) are not exceeded: ❑ Gas cookers Load of one hotplatemax. 03.0 kW Load of all hotplates max. 08.3 kW Load of the oven max. 03.9 kW ❑ Gas hobs Load of one hotplatemax. 03.9 kW Load of all hotplates max. 11.3 kW ❑ Gas glass-ceramic hotplate The data on...
Page 23
23 Prior to installation Exhaust-air mode The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. DExhaust air should neither be directed into a smoke or exhaust flue that is currently used for other purposes, nor into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located. Exhaust air may be discharged in accordance with official and statutory regulations only (e.g. national building regulations). Local...
Page 24
24 Prior to installation 2.Insert the one-way flap into the bearing apertures on the air-pipe connector. If the exhaust air is going to be discharged into the open, a telescopic wall box should be fitted into the outside wall. For optimum extractor hood efficiency: ❑ Short, smooth air exhaust pipe. ❑ As few bends in the pipe as possible. ❑ Diameter of pipe to be as large as possible (ideal is l120 mm ) and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe...
Page 25
25 Prior to installation Connecting the l120 mm exhaust-air pipe: ❑ Cut out the protective grid in the air outlet. Circulating-air mode ❑With activated carbon filter if exhaust-air mode is not possible. The complete installation set can be obtained from specialistoutlets. The corresponding accessory numbers can be found at the end of these opera- ting instructions. O 100 120 Exhaust flows straight out at the back: – inside the wall cupboard –. ❑ Cut a hole in the rear panel of the wall cupboard,...
Page 26
26 Preparing the wall cupboard Ensure that there is a minimum gap between hob and extractor hood of 650 mm (for gas hobs) or 430 mm (for electric hobs). This extractor hoodhas been designed for installation inside a wall cupboard with the following dimensions: Width: 600 mm Depth: 280 bis 350 mm Height: at least 300 mm. Preparation: 1.Remove bottom panel of cupboard – if fitted. The stability of the cupboard must be maintained. 2.Mark two points – right and left – on the inside of the cupboard where...
Page 27
27 Preparing the wall cupboardInstallation inside the wall cupboard 3.Align and screw on the enclosed mounting rails. Note the thickness of the sides of the cupboard (16 mm or 19 mm). dimension X. 1.Remove the filter frames (see Operating Manual). 2.If the hinges are no longer accessible when the extractor hood has been installed, align the cupboard doors. 3.Lift and push the extractor hood from below into the cupboard until the installation aids on the left and right lock into position. If the...
Page 28
28 Installation inside the wall cupboard 7.Feed the mains connection cable through the aperture into the upper cupboard and connect the pipe. 8.Connect to the power supply. 9.If required, shorten the wall cover to the required size (e.g. saw off) and screw to the upper cupboard. Attaching a handle: ❑ A handle must be attached to the filter drawer. ❑ This handle can either be a wooden strip that matches the kitchen cupboards or a the handle that is available as an optional accessory (see section on...
Page 29
29 Description de lappareil Modes de fonctionnement Air évacué à lextérieur: ❑Le ventilateur de la hotte aspire les buées de cuisson qui traversent un filtre à graisse avant de regagner latmosphère extérieure. ❑Ce filtre retient les particules grasses solides en suspension dans les buées de cuisson. ❑Les particules grasses ne se déposent plus dans la cuisine, les odeurs de cuis- son disparaissent. DSi la hotte évacue lair à lextérieur et si le logement comporte des moyens de chauffage (tels par ex. des...
Page 30
30 Avant la première utilisation Ne flambez aucun mets sous la hotte. Les flammes risqueraient datteindre le !filtre à graisse et dy mettre le feu. Lutilisation dune hotte aspirante au-dessus dun foyer à combustible solide (charbon, bois, etc.) nest autorisée quà certaines conditions (voir la notice de montage). Table de cuisson au gaz / Cuisinières à gaz Utilisez toujours les foyers au gaz correctement. Important: Les flammes produites par les foyers au gaz doivent toujours être recouvertes par la...