Page 11
11www.bissell.com 800.237.7691 Maintenance and care Cleaning the secondary cyclone Unplug the cleaner from electrical outlet. 1. The secondary cyclone can be reached by removing the dirt container, reaching underneath the upper tank and turning the rim of the frame to unlock. Pull straight down to remove. 2. The cyclone and screen may be separated for cleaning. Simply pull up on the screen to separate. 3. The upper tank may also be wiped clean with a damp cloth. 1. Unplug the vacuum from...
Page 12
Maintenance and care Check your vacuum cleaner’s rotating floor brush and drive belt regularly for debris, wear or damage. Debris can wrap around the brush and hamper its ability to effectively clean your carpet. 1. Unplug cleaner from electrical outlet. 2. Remove detachable canister from vacuum cleaner 3. Recline handle and turn vacuum cleaner over so bottom side is up. 4. Remove the six screws as shown with a Phillips head screwdriver. Lift the brush cover off. 5. Lift the rotating floor brush...
Page 13
WARnIn G: To reduce the risk of electric shock, turn Power Switch Off and disconnect polarized plug from electrical outlet before performing maintenance or troubleshooting checks. Maintenance and care Replace light bulb 1. Unplug cleaner from electrical outlet. 2. Remove detachable canister and recline handle of vacuum. 3. Using a screwdriver, remove the one screw as shown and lift off the lens. 4. Remove the bulb from the socket by grasping bulb and pulling straight out. Install the new...
Page 14
Maintenance and care Cleaning clogs Low suction or poor pickup may be due to a clog in the vacuum cleaner. If you notice a change in the sound of the motor or a reduction in the spinning action, check for clogs. 1. Unplug cleaner from electrical outlet. 2. Empty Dirt Container. 3. Check Upper Tank for build up or clogs. 4. Remove the secondary cyclone and check the suction inlet for a clog. 5. Grasp the Hose Grip and lift to separate from the suction opening. Check for a clog in the Base...
Page 15
Maintenance and care Thermal protector An internal thermal protector has been designed into your cleaner to protect it from overheating. When the thermal protector activates, the main vacuum motor will stop operating. If this happens, proceed as follows: 1. Turn the cleaner OFF (O) and unplug from electrical outlet. 2. Check the secondary cyclone area, Pre- Motor Filter and Post-Motor Filter for dirt accumulation. 3. Refer to the "Clearing Clogs" section. 4. When the motor cools for...
Page 16
WARnIn G: To reduce the risk of electric shock, turn power Off and disconnect polarized plug from electrical outlet before performing maintenance or troubleshooting. Troubleshooting Vacuum cleaner won’t run Possible causes Remedies 1. Power cord not firmly plugged in 1. Check electrical plug 2. Blown fuse/tripped breaker 2. Check/replace fuse or reset breaker 3. Thermal protector activated 3. Allow cleaner to cool for 30 minutes, see page 15 no power at rotating floor brush...
Page 17
Troubleshooting Visible dirt escaping from cleaner Possible causes Remedies 1. Dirt container full 1. Empty dirt container 2. Filter or secondary cyclone missing or installed incorrectly 2. Check secondary cyclone, pre-motor and post-motor filter for correct installation 3. Dirt container installed incorrectly 3. Pull out and re-insert dirt container correctly Other maintenance or service not included in the manual should be performed by an authorized service representative. Thank you for...
Page 18
1234 5678 BISSELL consumer service For information about repairs or replacement parts, or questions about your warranty, call: BISSELL Consumer Services 1-800-237-7691 Monday - Friday 8 a.m. — 10 p.m. ET Saturday 9 a.m. — 8 p.m. ET Or write: BISSELL Homecare, Inc. PO Box 3606 Grand Rapids, MI 49501 ATTN: Consumer Services Or visit the BISSELL website - www.bissell.com When contacting BISSELL, have model number of unit available. Please record your Model Number: _______________Please record your...
Page 19
You may purchase replacement parts from your retailer, by calling BISSELL Consumer Services or by visiting our website. To locate a retailer near you, or to place an order using Visa, MasterCard, Discover or American Express, call BISSELL Consumer Services 1-800-237-7691 Monday - Friday 8 a.m. — 10 p.m. ET Saturday 9 a.m. — 8 p.m. ET Or visit our Website - www.bissell.com Item Part no. Part name 1 3200 Style 8 Drive Belt (2-Pack) 2 203-1297 Standard Headlight Bulb 3 203-2073 Twist...
Page 20
20www.bissell.com 800.237.7691 Warranty ©2009 BISSELL Homecare, Inc Grand Rapids, Michigan All rights reserved. Printed in Korea Part Number 110-4086 Rev 2/09 Visit our website at: www.bissell.com This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. If you need additional instruction regarding this warranty or have questions regarding what it may cover, please contact BISSELL Consumer Services by E-mail, telephone, or regular mail as...