475 or 476 Printer Used as Journal Printer for Hosp itality 
Feature
September 1995 Issue 1 
H-25
Switch 22
1 OFF Baud Rate*
2ON
3ON
4 OFF Not Used
Switch 23
1 ON RS232
2 OFF
3 OFF Use of DSR
4 OFF
5ON
6 OFF Not Used
Switch 24
1 ON Select DTR Timing
2ON
3 OFF Select RTS Timing
4ON
5 ON Use of CTS
6 OFF
7 OFF
8ON
* The Baud Rate Default is 1200 baud. Any speed
can be used, b ut the speed of the printer and
any connection devic e used must match.
Table H-18. Option Switch Settings for 475 Printer...

Page 282

O ption Switch Setting s
H-26Septemb er 1995 Issue 1  
Table H-19. Option Switch Settings for a 475 or 
476 Journal Printer
Section Setting Description
Switch 1
1 OFF Character Set
2ON
3 OFF
4 OFF
5 OFF DC1 and DC3
6 ON Line Feed
7 ON Print Command Mode
8 OFF LF o n  CR
Switch 2
1 OFF Numeric Display of Zero
2 OFF Buffer Selection
3 OFF TOF-to-TOF
4 OFF Power on Line Feed Pitc h
5 OFF Power on Character Pitc h
6 ON Selection on 7 or 8 Bit Data
7 ON Power on Off-Line or Ready
8 OFF Uni- or Bi-Directional...

Page 283

475 or 476 Printer Used as Journal Printer for Hosp itality 
Feature
September 1995 Issue 1 
H-27
Switch 22
1 OFF B a u d  Rat e
2 OFF
3 OFF
4 OFF Not Used
Switch 23
1 ON RS232
2 OFF
3 OFF Use of DSR
4 OFF
5ON
6 OFF Not Used
Switch 24
1 OFF Select DTR Timing
2ON
3 ON Select RTS Timing
4 OFF
5 OFF U se  of  C TS
6ON
7 OFF
8ON Table H-19. Option Switch Settings for a 475 or 
476 Journal Printer — Continued  
Section Setting Description
Continued on next page 

Page 284

O ption Switch Setting s
H-28Septemb er 1995 Issue 1  
470 or 471 Printer Used as Journal
Printer for Hospitality Feature
A p rinter can be connected to the switch to provide hard  copy of hospitality 
related data. Table H-21 shows the o ption switch settings for the 470 or 471 
printers when they are used in this application. Table H-20. Option Switch Settings on Modular Processor 
Data Module (MPDM) or Modular Trunk Data 
Module (MTDM) for 475 or 476 Journal Printer
Switch Setting
SELF TEST OFF
LOC...

Page 285

470 or 471 Printer Used as Journal Printer for Hosp itality 
Feature
September 1995 Issue 1 
H-29
Table H-21. Option Switch Settings for a 470 or 
471 Journal Printer
Section Setting Description
Switch 1
1 OFF Character Set
2ON
3 OFF
4 OFF
5 OFF DC1 and DC3
6 ON Line Feed
7 ON Print Command Mode
8 OFF LF o n  CR
Switch 2
1 OFF Numeric Display of Zero
2 OFF Buffer Selection
3 OFF TOF-to-TOF
4 OFF Power on Line Feed Pitc h
5 OFF Power on Character Pitc h
6 ON Selection on 7 or 8 Bit Data
7 ON Power on...

Page 286

O ption Switch Setting s
H-30Septemb er 1995 Issue 1  
572 Printer
A 572 printer c an function as a G3 Management Terminal, station message d etail 
recording (SMDR), system printer, or journal printer. The options on the 572 
printer are set with function keys rather than d ual in-line package switches. 
Figure H-1 shows the arrangement of the function keys on the printer control 
panel.
Figure Notes:
Figure H-1. Control Panel for 572 Printer
NOTE:
Before attempting to set the printer options, ensure...

Page 287

572 Printer
September 1995 Issue 1 
H-31
2. If the printer is to be used with the G3 Management Terminal, station 
message detail recording (SMDR), or as a Journal printer, set the o ptions 
as shown in Table H-22. If the printer is being used as the system printer, 
set the options as shown in Table H-23.
nUse Line Feed button to step forward through the list of functions or 
use Form Feed button to step backward 

Page 288

O ption Switch Setting s
H-32Septemb er 1995 Issue 1  
.
Table H-22. 572 Printer Used with G3 Management Terminal,
Station Message Detail Recording (SMDR) or 
Journal Printer
572 Printer Option Settings
Function Function Menu Menu
Number Name Number Status
01 FORM  LENGTH 09 11
02 LPI 01 6
03 CPI 01 10
04 LQ or NLQ 01 LQ
05 BUZZER 01 ON
06 FONT 02 FONTCART
07 RESOLUTION 01 144
1 1 BUFFER 0 2 N-LINE
13 PW ON MODE 01 ON-LINE
14 DIRECTION 01 B1-DIR.1
15 BUFF FULL 02 LF + CR
16 P.E. 01 ACTIVE
17 AUTO...

Page 289

572 Printer
September 1995 Issue 1 
H-33
93 PROTOCOL 03 XON/XOFF
9 4 STOP BIT 0 1 1
9 5 PARI TY 0 1 NO NE
96 PBS 01 9600
Table H-22. 572 Printer Used with G3 Management Terminal,
Station Message Detail Recording (SMDR) or 
Journal Printer
572 Printer Option Settings
Function Function Menu Menu
Number Name Number Status 

Page 290

O ption Switch Setting s
H-34Septemb er 1995 Issue 1  
Table H-23. 572 Printer used as System Printer
572 Printer Option Settings
Function Function Menu Menu
Number Name Number Status
01 FORM  LENGTH 09 11
02 LPI 01 6
03 CPI 01 10
04 LQ or NLQ 01 LQ
05 BUZZER 01 ON
06 FONT 02 FONTCART
07 RESOLUTION 01 144
1 1 BUFFER 0 2 N- LI NE
13 PW ON MODE 01 ON-LINE
14 DIRECTION 01B1-DIR.1
15 BUFF FULL 02 LF + CR
16 P. E. 01 ACTIVE
17 AUTO CARRIAGE 
RETURN (CR)01 CR +  LF
18 ZERO 01 0
22 AUTO LINE FEED 01 CR ONLY
31...