Page 281
475 or 476 Printer Used as Journal Printer for Hosp itality Feature September 1995 Issue 1 H-25 Switch 22 1 OFF Baud Rate* 2ON 3ON 4 OFF Not Used Switch 23 1 ON RS232 2 OFF 3 OFF Use of DSR 4 OFF 5ON 6 OFF Not Used Switch 24 1 ON Select DTR Timing 2ON 3 OFF Select RTS Timing 4ON 5 ON Use of CTS 6 OFF 7 OFF 8ON * The Baud Rate Default is 1200 baud. Any speed can be used, b ut the speed of the printer and any connection devic e used must match. Table H-18. Option Switch Settings for 475 Printer...
Page 282
O ption Switch Setting s H-26Septemb er 1995 Issue 1 Table H-19. Option Switch Settings for a 475 or 476 Journal Printer Section Setting Description Switch 1 1 OFF Character Set 2ON 3 OFF 4 OFF 5 OFF DC1 and DC3 6 ON Line Feed 7 ON Print Command Mode 8 OFF LF o n CR Switch 2 1 OFF Numeric Display of Zero 2 OFF Buffer Selection 3 OFF TOF-to-TOF 4 OFF Power on Line Feed Pitc h 5 OFF Power on Character Pitc h 6 ON Selection on 7 or 8 Bit Data 7 ON Power on Off-Line or Ready 8 OFF Uni- or Bi-Directional...
Page 283
475 or 476 Printer Used as Journal Printer for Hosp itality Feature September 1995 Issue 1 H-27 Switch 22 1 OFF B a u d Rat e 2 OFF 3 OFF 4 OFF Not Used Switch 23 1 ON RS232 2 OFF 3 OFF Use of DSR 4 OFF 5ON 6 OFF Not Used Switch 24 1 OFF Select DTR Timing 2ON 3 ON Select RTS Timing 4 OFF 5 OFF U se of C TS 6ON 7 OFF 8ON Table H-19. Option Switch Settings for a 475 or 476 Journal Printer — Continued Section Setting Description Continued on next page
Page 284
O ption Switch Setting s H-28Septemb er 1995 Issue 1 470 or 471 Printer Used as Journal Printer for Hospitality Feature A p rinter can be connected to the switch to provide hard copy of hospitality related data. Table H-21 shows the o ption switch settings for the 470 or 471 printers when they are used in this application. Table H-20. Option Switch Settings on Modular Processor Data Module (MPDM) or Modular Trunk Data Module (MTDM) for 475 or 476 Journal Printer Switch Setting SELF TEST OFF LOC...
Page 285
470 or 471 Printer Used as Journal Printer for Hosp itality Feature September 1995 Issue 1 H-29 Table H-21. Option Switch Settings for a 470 or 471 Journal Printer Section Setting Description Switch 1 1 OFF Character Set 2ON 3 OFF 4 OFF 5 OFF DC1 and DC3 6 ON Line Feed 7 ON Print Command Mode 8 OFF LF o n CR Switch 2 1 OFF Numeric Display of Zero 2 OFF Buffer Selection 3 OFF TOF-to-TOF 4 OFF Power on Line Feed Pitc h 5 OFF Power on Character Pitc h 6 ON Selection on 7 or 8 Bit Data 7 ON Power on...
Page 286
O ption Switch Setting s H-30Septemb er 1995 Issue 1 572 Printer A 572 printer c an function as a G3 Management Terminal, station message d etail recording (SMDR), system printer, or journal printer. The options on the 572 printer are set with function keys rather than d ual in-line package switches. Figure H-1 shows the arrangement of the function keys on the printer control panel. Figure Notes: Figure H-1. Control Panel for 572 Printer NOTE: Before attempting to set the printer options, ensure...
Page 287
572 Printer September 1995 Issue 1 H-31 2. If the printer is to be used with the G3 Management Terminal, station message detail recording (SMDR), or as a Journal printer, set the o ptions as shown in Table H-22. If the printer is being used as the system printer, set the options as shown in Table H-23. nUse Line Feed button to step forward through the list of functions or use Form Feed button to step backward
Page 288
O ption Switch Setting s H-32Septemb er 1995 Issue 1 . Table H-22. 572 Printer Used with G3 Management Terminal, Station Message Detail Recording (SMDR) or Journal Printer 572 Printer Option Settings Function Function Menu Menu Number Name Number Status 01 FORM LENGTH 09 11 02 LPI 01 6 03 CPI 01 10 04 LQ or NLQ 01 LQ 05 BUZZER 01 ON 06 FONT 02 FONTCART 07 RESOLUTION 01 144 1 1 BUFFER 0 2 N-LINE 13 PW ON MODE 01 ON-LINE 14 DIRECTION 01 B1-DIR.1 15 BUFF FULL 02 LF + CR 16 P.E. 01 ACTIVE 17 AUTO...
Page 289
572 Printer September 1995 Issue 1 H-33 93 PROTOCOL 03 XON/XOFF 9 4 STOP BIT 0 1 1 9 5 PARI TY 0 1 NO NE 96 PBS 01 9600 Table H-22. 572 Printer Used with G3 Management Terminal, Station Message Detail Recording (SMDR) or Journal Printer 572 Printer Option Settings Function Function Menu Menu Number Name Number Status
Page 290
O ption Switch Setting s H-34Septemb er 1995 Issue 1 Table H-23. 572 Printer used as System Printer 572 Printer Option Settings Function Function Menu Menu Number Name Number Status 01 FORM LENGTH 09 11 02 LPI 01 6 03 CPI 01 10 04 LQ or NLQ 01 LQ 05 BUZZER 01 ON 06 FONT 02 FONTCART 07 RESOLUTION 01 144 1 1 BUFFER 0 2 N- LI NE 13 PW ON MODE 01 ON-LINE 14 DIRECTION 01B1-DIR.1 15 BUFF FULL 02 LF + CR 16 P. E. 01 ACTIVE 17 AUTO CARRIAGE RETURN (CR)01 CR + LF 18 ZERO 01 0 22 AUTO LINE FEED 01 CR ONLY 31...