Page 181
9-5 6Issue 1 September 1995 Processor Data Mo dules (PDMs) are connected to TN754B d i gital line circuit packs and are mounted individually or in a 71A data mounting. Other digital-line circuit packs may be required in some countries. Each 71A d ata mounting can contain up to eight modules. This document contains only the information required to connect the modules to the switch. Module installation and testing information is contained in AT&T System 75 User’s Guid e—Processor Data Module ,...
Page 182
Install Processor Data Modules (PDMs) Issue 1 September 1995 9-5 7 Figure 9-29. Connections for Processor Data Modules (PDMs) in Data Mounting Connection to Individual Processor Data Modules (PDMs) 1. Determine port assignment of the Processor Data Mo dule (PDM) from the Data Module Form: 2. Install the module per instructions in AT&T System 75 User’s Guid e— Processor Data Mo dule, 999-700-028. 3. Install patch cord /jumper wires at cross-c onnect field. EXAMPLE: Port Numb er 2 B 02 01...
Page 183
9-5 8Issue 1 September 1995 4. Administer according to the instructions in the following United States English b ook: nDEFI NI TY Com munications System Generic 3 V2 Implementation, 555-230-655 Figure 9-30. Connections for Individual Processor Data Modules (PDM) Install Call Management System (CMS) Interface The interface between the switch and the Call Management System (CMS) is through Processor Data Mo dules (PDMs). The DEFI NIT Y System G3i uses the processor interface (TN765) as the...
Page 184
Install Property Management System (PMS) Interface Issue 1 September 1995 9-5 9 option switches is contained in the 3B2 Messaging Server Installation and Maintenance Service Manual , 585-205-110. The Call Management System (CMS) connection is illustrated b elow. Figure 9-31. Typical Call Management System (CMS) Connections to DEFINITY System G3i Using Mode Conversion Install Property Management System (PMS) Interface This section describes how to install the Property Management System (PMS)...
Page 185
9-6 0Issue 1 September 1995 Refer to the vendor’s documentation for connecting to the Property Management System (PMS). The option switches on the Processor Data Module (PDM) must be set in accordance with the requirements for the customers Property Management System (PMS). A journal p rinter can b e used. The connections for the printer are the same as for the Property Management System (PMS). Refer to the vendor’s documentation for connecting the Processor Data Modules (PDMs) to the printer and...
Page 186
Install Customer-Provided Terminal Using Asynchronous Data Unit (ADU) Issue 1 September 1995 9-6 1 Figure 9-32. Connections to Asynchronous Data Unit (ADU) for Data Terminal Equipment (DTE) Install Customer-Provided Terminal Using Asynchronous Data Unit (ADU) Requirements The interface between the switch and the customer’s data terminals and host computer can be through Processor Data Mo dules (PDMs). Refer to section on installing Processor Data Modules (PDMs) for d etails. Asynchronous data...
Page 187
9-6 2Issue 1 September 1995 3. Refer to Figure 9-32 for an illustration. Install Station Message Detail Recording (SMDR)/Call Detail Recording Unit (CDRU) Interface The interface between the switch and Station Message Detail Recording (SMDR) can b e through a Processor Data Module (PDM), Trunk Data Mo dule (TDM), or 212-type modem. For connections b etween the switch and the Processor Data Module (PDM) or Trunk Data Module (TDM), refer to the section on installing Processor Data Modules...
Page 188
Install Station Message Detail Recording (SMDR)/Call Detail Recording Unit (CDRU) Interface Issue 1 September 1995 9-6 3 Interface Cabling to Station Message Detail Recording (SMDR) Output Device Figure 9-33 shows the c a bling required to connect the TELESEER unit, printer, or customer-provided data terminal equipment (DTE) for an AC-powered single- carrier cabinet. The M25B/RS-232 cable connects to the PI connector on the TELE SE ER unit. !CAUTION: All peripherals connected to a DC-powered...
Page 189
9-6 4Issue 1 September 1995 Figure 9-33. Station Message Detail Recording (SMDR) Cabling for On-Premises Data Communications Equipment (DCE) from AC Powered Single-Carrier Cabinet 2 3 8 4 95 10 11 7 7 6 66 66 6 1 1. 25-pin RS232 cable 2. Digital line circuit pack (TN754) 3. Analo g line circuit pack TN746) 4 . RS 23 2 d at a t erm in al e q u i p m en t (DTE ) connector on back of cabinet 5. 94 A loc al sto rag e u ni t (L SU) or Prin te r, or customer-provided data communications e quipment...
Page 190
Install Station Message Detail Recording (SMDR)/Call Detail Recording Unit (CDRU) Interface Issue 1 September 1995 9-6 5 Figure 9-34 shows the connections for a remote host connected by a private line. Figure Notes: Figure 9-34. Station Message Detail Recording (SMDR) Cabling for Remote Host Switch Settings for Processor Data Module (PDM), Trunk Data Module (TDM), or 212-Type Modem Set the o ption switches for the Processor Data Module (PDM) and the Trunk Data Mo dule (TDM) as follows: Switch...