Home > ATT > Communications System > ATT DEFINITY Communications System Generic 3 For Single-Carrier Cabinets Instructions Manual

ATT DEFINITY Communications System Generic 3 For Single-Carrier Cabinets Instructions Manual

Here you can view all the pages of manual ATT DEFINITY Communications System Generic 3 For Single-Carrier Cabinets Instructions Manual. The ATT manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 181

9-5 6Issue 1  September 1995  
Processor Data Mo dules (PDMs) are connected to TN754B d i gital line circuit 
packs and are mounted individually or in a 71A data mounting. Other digital-line 
circuit packs may be required in some countries. Each 71A d ata mounting can 
contain up to eight modules. This document contains only the information 
required to connect the modules to the switch. Module installation and testing 
information is contained in 
AT&T System  75  User’s  Guid e—Processor Data 
Module
,...

Page 182

Install Processor Data Modules (PDMs)
Issue 1  September 1995 
9-5 7
Figure 9-29. Connections for Processor Data Modules (PDMs) in 
Data Mounting
Connection to Individual Processor Data 
Modules (PDMs)
1. Determine port assignment of the Processor Data Mo dule (PDM) from 
the Data Module Form:
2. Install the module  per instructions in 
AT&T System  75  User’s  Guid e—
Processor Data Mo dule, 999-700-028.
3. Install patch cord /jumper wires at cross-c onnect field. EXAMPLE:   Port Numb er 2 B 02 01...

Page 183

9-5 8Issue 1  September 1995  
4. Administer according to the instructions in the following United States 
English b ook:
nDEFI NI TY Com munications System Generic 3 V2 Implementation, 
555-230-655
Figure 9-30. Connections for Individual Processor Data Modules 
(PDM)
Install Call Management System 
(CMS) Interface
The interface between the switch and the Call Management System (CMS) is 
through Processor Data Mo dules (PDMs). The DEFI NIT Y System G3i uses the 
processor interface (TN765) as the...

Page 184

Install Property Management System (PMS) Interface
Issue 1  September 1995 
9-5 9
option switches is contained in the 3B2 Messaging Server Installation and 
Maintenance Service Manual
, 585-205-110.
The Call Management System (CMS) connection is illustrated b elow.
Figure 9-31. Typical Call Management System (CMS) 
Connections to DEFINITY System G3i 
Using Mode Conversion
Install Property Management System 
(PMS) Interface
This section describes how to install the Property Management System (PMS)...

Page 185

9-6 0Issue 1  September 1995  
Refer to the vendor’s documentation for connecting to the Property Management 
System (PMS). The option switches on the Processor Data Module (PDM) must 
be set in accordance with the requirements for the customers Property 
Management System (PMS).
A journal p rinter can b e used. The connections for the printer are the same as for 
the Property Management System (PMS). Refer to the vendor’s documentation 
for connecting the Processor Data Modules (PDMs) to the printer and...

Page 186

Install Customer-Provided Terminal Using 
Asynchronous Data Unit (ADU)
Issue 1  September 1995 
9-6 1
Figure 9-32. Connections to Asynchronous Data Unit (ADU) for 
Data Terminal Equipment (DTE)
Install Customer-Provided Terminal 
Using Asynchronous Data Unit (ADU)
Requirements
The interface between the switch and the customer’s data terminals and host 
computer can be through Processor Data Mo dules (PDMs). Refer to section on 
installing Processor Data Modules (PDMs) for d etails.
Asynchronous data...

Page 187

9-6 2Issue 1  September 1995  
3. Refer to Figure 9-32 for an illustration.
Install Station Message Detail 
Recording (SMDR)/Call Detail 
Recording Unit (CDRU) Interface
The interface between the switch and Station Message Detail Recording 
(SMDR) can b e through a Processor Data Module (PDM), Trunk Data Mo dule 
(TDM), or 212-type modem. 
For connections b etween the switch and the Processor Data Module (PDM) or 
Trunk Data Module (TDM), refer to the section on installing Processor Data 
Modules...

Page 188

Install Station Message Detail Recording (SMDR)/Call 
Detail Recording Unit (CDRU) Interface
Issue 1  September 1995 
9-6 3
Interface Cabling to Station Message Detail
Recording (SMDR) Output Device
Figure 9-33 shows the c a bling required to connect the TELESEER unit, printer, 
or customer-provided data terminal equipment (DTE) for an AC-powered single-
carrier cabinet. The M25B/RS-232 cable connects to the PI connector on the 
TELE SE ER  unit. 
!CAUTION:
All peripherals connected to a DC-powered...

Page 189

9-6 4Issue 1  September 1995  
Figure 9-33. Station Message Detail Recording (SMDR) Cabling 
for On-Premises Data Communications Equipment 
(DCE) from AC Powered Single-Carrier Cabinet
2
3
8
4
95
10
11
7
7
6
66
66
6
1
1. 25-pin RS232 cable
2. Digital line circuit pack (TN754)
3. Analo g line circuit pack TN746)
4 . RS 23 2  d at a t erm in al  e q u i p m en t (DTE ) 
connector on back of cabinet
5. 94 A loc al  sto rag e u ni t (L SU) or Prin te r, 
or customer-provided data 
communications e quipment...

Page 190

Install Station Message Detail Recording (SMDR)/Call 
Detail Recording Unit (CDRU) Interface
Issue 1  September 1995 
9-6 5
Figure 9-34 shows the connections for a remote host connected by a private 
line.
Figure Notes:
Figure 9-34. Station Message Detail Recording (SMDR) Cabling 
for Remote Host
Switch Settings for Processor Data Module
(PDM), Trunk Data Module (TDM), or 212-Type
Modem
Set the o ption switches for the Processor Data Module (PDM) and the Trunk 
Data Mo dule (TDM) as follows:
Switch...
Start reading ATT DEFINITY Communications System Generic 3 For Single-Carrier Cabinets Instructions Manual

Related Manuals for ATT DEFINITY Communications System Generic 3 For Single-Carrier Cabinets Instructions Manual

All ATT manuals