Page 11
September 2012 L01015511 RS232 to RS485 for Multiple units or cables longer than 50ft The DPD75601 can be connected to your PC serial port via a RS485 converter (model number: 485SD9TB sold separately). This converter will convert the RS232 voltage signals to the com- patible RS485 differential signals. Only one converter box is needed per serial port. Contact the factory or use the website www.anaheimautomation.com for RS485 converter information and sales. Terminating Resistor To eliminate noise...
Page 12
September 2012 L01015512 Move Number of Steps: This command causes the motion to start in the direction last specifi ed. This command will move the motor the number of steps given. (Range: 1 to 8388607) Move to Position: The move to position command specifi es the next absolute position to go to. The DPD75601 controller automatically sets the direction and number of steps needed to go to that posi- tion. (Range: -8388607 to +8388607) Slew: The slew command will accelerate the motor up to maximum...
Page 13
September 2012 L01015513 Jog Inputs: The jog switch inputs are internally pulled up by a resistor making them normally +5 volts. To activate the input, the pin must be grounded to (0VDC). All jog switch inputs are internally clamped to +5V, thus allowing voltages of up to +24VDC to be used. Jog is a manual function. The user can select the direction and speed (fast or slow) by grounding the appropriate combinations of inputs. To jog a mo- tor, it is necessary to ground the jog input for the...
Page 14
September 2012 L01015514 Output on the fl y: This special function enables output 1 to turn on during a relative index or absolute move. There are three critical portions of information needed to make this function work correctly. First, output 1 will turn on (0VDC) for a preset delay of 50uS at a specifi c absolute position set by the 1 st output position command. Second, the output can then repeat this after a preset amount of steps set by the number of steps between outputs command, and third a...
Page 15
September 2012 L01015515 Encoder Commands: The DPD75601 controller is capable of using a quadrature incremental encoder with A and B channels. Encoder Auto Correct: This command will enable or disable the encoder feature of the DPD75601. When enabled, the encoder function will compare the desired position with the actual encoder position. If it is not in the correct position a correction move will be made. Encoder Delay: This sets the wait time, which is a specifi ed number of milliseconds after a...
Page 16
September 2012 L01015516 The SMC60WIN software is a handy utility that supports Anaheim Automation’s line of DPD75601’s step motor controllers. Connecting your PC to the DPD75601, via a serial cable, the SMC60WIN software can easily perform the following tasks: • Exercise and monitor the DPD75601 controller • Write and edit stored programs for standalone operation • Directly communicate with the DPD75601 controller Section 4: SMC60WIN Software Installation Software • The SMC60WIN is supplied on a...
Page 17
September 2012 L01015517 File Menu Setup Menu Setup - Axis Menu Connect Establish communications with the controller. Disconnect Release the COM port for other devices to use. Com Port Settings Select COM port. Axis Set axis selection and stored axis of the controller. Select Axis Sets the axis select parameter in the SMC60WIN software. (1-99) Defi ne Axis Sets the programmable address in the controller. (1-99) New Program Start editing a new program. Open Program Open an existing program from disk. Save...
Page 18
September 2012 L01015518 Program Menu Program - Autostart Program Menu Edit Menu Disable Program will disable the execution of a store program at power up. Enable Program will start execution when controller is powered up. Start Program Start the execution of the program in the controller memory. Stop Program Stop the execution of the program in the controller memory. View Program View the program stored in the controller memory. Clear Program Memory Clear the program memory in the controller. Autostart...
Page 19
September 2012 L01015519 Help Menu Error Coder Reader Utility to read the error code generated by the DPD75601 controller. PCL601 User’s Guide Opens up the User’s Guide in .pdf format. www.anaheimautomation.comOpens up the Anaheim Automation Website. About Displays the verison of the SMC60WIN and contact information. “The Unit is Connected” / “The Unit is Not Connected” On the right of the Toolbar, the user will fi nd the communication status of the DPD75601 control- ler. If communications is not...
Page 20
September 2012 L01015520 Toolbar Exit Exit the SMC60WIN software. New Start editing a new program. Open Open an existing program from disk or directory. Save Save the current program to disk or directory. Print Print the current program. Calculator Open the desktop calculator. Stop All Stop the program and all motion from running. Connect Establish communication with the controller. Tab Sheets Real Time Motion Monitor and control motion of the controller. Encoder Options and Registration InputsMonitor...