Page 11
1718Figure 8. Motion Tab SMC35 Programmable Indexer Disks Included with the DPD72351 is the SMC35 Programmable Indexers Disks. These disks contain all of the software needed to run the indexer via a PC. Also included in the disks are examples programs that can be downloaded into the indexer. This software requires a minimum system of a 486/66MHz processor with 8Mbytes of RAM and Windows 3.1. Running the Setup.exe from disk 1 of the SMC35 Programmable Indexer Disks will install the software into the...
Page 12
1920PROGRAMMING COMMANDSCommands are sent to the DPD72351 by a computer, dumb terminal, or handheld terminal. These commands must be sent in ASCII by a RS232 or RS422 communications format. RS232 is used most commonly by computers. Commands are made up of one or two letters, possibly followed by one or more numbers. All letters are upper case 8-bit ASCII characters with the most significant bit ignored. All numbers are ASCII sent with the most significant digit first. Spaces can be imbedded with no...
Page 13
2122Number Range Byte Count 1 - 255 1 256 - 65,535 2 65536 - 167772153 ASCII character 1 TABLE 14: ASCII BYTE COUNT Verify V Direct verify specified data Wait Wxx Both wait for a period of time in (.01 sec increments) Continue X Direct continue internal program Zero Zrrrrr Both set position register...
Page 14
2324COMMAND DICTIONARY A (2 to 127) The ACCELERATION command controls the time that the motor will take to move from base speed to maximum speed. The higher the value, the slower the motor will accelerate. The default value is 5. B (50 to 3500) The BASE SPEED is the speed at which motion starts and stops. It is entered directly as the number of steps per second. This is also the stepping rate in the Fast Jog Mode. Not all base speeds will be possible. On the computer, if you enter B2455, and...
Page 15
2526G (no value) The GO command causes the motion to start in the direction last 34 = 2 + 32 specified. This command will move the motor the number of steps given by the N command or to the absolute position given by the P command. This is one of three ways to start motion; the other two are the H command and the S command. H (0 or 1) The HOME command starts the controller searching for Home in the direction last set. Motion will start immediately after a terminator , is supplied. There are...
Page 16
2728Maximum Speed can never be set below the Base Speed.SAMPLE STORED PROGRAMN (1 to 16,777,215) This specifies the NUMBER OF STEPS to be moved forAddressCommandRemarksthe Go command. The default value on power up is 0. 20A5Set acceleration to 5 Oxx,yy (0 to 255,0 to 255) The OUTPUT command reads set the outputs 24M5000Set Maximum Speed to 5000 defined by mask xx to the binary-weighted number specified by yy. (See 27I1,1,33If INPUT #0 is high then go to address 33 INPUT command for...
Page 17
2930VA Acceleration VB Base Speed VCPEncoder Position VDDeceleration VEInternal Program VGStep remaining in current move VHHold Time VI Input Terminals VJ Slow Jog Divisor VMMaximum Speed VN Number of Steps to Index VOOutput Terminals VP Position VR Internal Program Pointer VW...
Page 18
3132of move. The responses are defined in Table 15. As in the Verify command, only one axis at a time may be addressed with this command. The POLL command is especially useful in debugging a program. #DESCRIPTION 0 Normal 1 Command error, illegal command sent 2 Range error, an out of range number was sent 3 Command invalid while moving 4 Command only valid in stored...
Page 19
3334BLD72 DRIVER SPECIFICATIONS Control Inputs (All) : (Terminals 5, 6, 8, 9) TTL-compatible Logic 0 - 0 to 0.8 V Logic 1 - 3.5 to 5.0 V Fault Reset: (Terminal 4) Pulled up to +5Vdc through a 10kÙ Logic 1 (open) - Driver enabled and Fault detection enabled Logic 0 - Resets a Fault condition (driver is disabled when this input is low). This input must be held low for at least 100ms. Clock Inputs : (Terminals 6) Internally connected to indexer. Direction Control: (Terminal 5) Internally connected...
Page 20
3536MOTOR POWER ON/OFF INPUTFigure 14 is a hookup diagram for typical BLD72 driver applications. Wiring con- The Motor On/Off input allows de-energizing a motor without disturbing thenected to inputs must be separated from motor connections and all other possible positioning logic. After re-energizing the motor, a routine can continue. Thissources of interference. reduces motor heating and conserves power, especially in applications where motors are stopped for long periods and no holding torque is...