    Have a look at the manual Amptron Educational Equipment Equipment Racking Systems User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 21 Amptron manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							EDUCATIONAL EQUIPMENTP O Box 137  Parow   7499 Bellville  7530  27 21 9300929 / 32  27 21 9300934Fax:E-mail:[email protected] site:Tel:Unit  8  Boulevard Park 
                       Off Boulevard Drive
    Cape Town MPTRONAELECTRONICS (Pty) LtdREG. NO: 79/02792/07 
    						
    							AC SUPPLYRated input voltage        220/230 V AC
    Rated input current        5 A
    Line frequency               50-60 Hz
    COMPONENTS1.2 K W isolating transformer with the following input taps 
    210, 220 and 230 volt AC. 
    COOLING                220 v 120 square fan
    AC OUTPUT
    Variac                              1.2 kW, 0 - 220 V AC 
    Rated output voltage     0 220 V AC
    Rated output current     5 A
    DC OUTPUT
    Rated output voltage      0 - 220 V DCRated output current      5 A
    bridge rectifier                35 A 1200V DC
    Capacitance  10000 micro farad 250 V
    PROTECTION Mains                        2 pole Hager 5 amp D curve MCB
    Primary fuse      5 Amp fuse
    Secondary         5 Amp fuse
    DC fuses            1 x 5 Amp fuse Negative
                                1 x 5 Amp fuse positive
                                                               SPECIFICATIONS220 VOLT AC/DC POWER SUPPLY 
    						
    							SPECIFICATIONSAC SUPPLYCOMPONENTS
      8 x Inductors              0.01 H at 50 Hz
      8 x Power resistors   1.5 Ohm 50 Watt
    12 x Capacitors          16m Farad 450 V                                          COOLING                         220 v 120 square fan
    PROTECTION Capacitor discharge resister built in
    Fan                                   125 mA fuse
                                                               Rated input voltage        380 V AC 5 wire system
    Rated input current        3 A
    Line frequency               50-60 Hz
    COMPONENTS
    3 x 600 W isolating transformer with the followinginput  taps  210, 220 and 230 volt V AC. 
    Total power consumption:  3 x 600 W = 1.8 K W
    AC OUTPUT
    Rated output voltage  60, 110, 170, 220 and 380V
    Rated output current  3 Amp
    COOLING                220 v 120 square fan
    Out going mains    3 x chassis mount socketsOn/Off illuminated latching contactor
    PROTECTION 
    Mains                3 pole M&G 3 amp D curve MCBMains incoming   3 x 3 Amp fuses
    Mains out going   1 x 5 amp fuse                                                           SPECIFICATIONSLINE SIMULATORLINE SIMULATOR       THREE PHASE POWER SUPPLY 
    SINGLE PHASE TRANSFORMER TRAINER        THREE PHASE POWER SUPPLY 
           SINGLE PHASE TRANSFORMER        TRAINER 
    						
    							RLC PANELSPECIFICATIONSAC SUPPLYAC SUPPLYRated input voltage        220 VAC
    Rated input current        125 mALine frequency                50-60 Hz
    COMPONENTSVariable inductor              400 mH at 50 Hz
    Variable power resistor   100 Ohm 500 Watt
    Capacitors                        selectable  in 1 m Fd                                          steps to 60 m Farad                                          450 V maximumCOOLING                         220 v 120 square fan
    PROTECTION
     Capacitor discharge resister built inVariable inductor            2.5 A fuse
    Var power resistor          2.5 A fuse
    Fan                                   125 mA fuse
                                                               Rated input voltage        380 V AC 5 wire system
    Rated input current        5 A
    Line frequency               50-60 Hz
    COMPONENTS1 x 380 V 3 K W multi tap transformer with taps 
    at0, 12, 24, 48, 60, 120 and 220 volt. Can be connected star to star, delta to delta, star delta
    and delta starCOOLING                220 v 120 square fanOut going mains    3 x chassis mount socketsthermocouples  embedded in transformer coreOn/Off illuminated latching contactorfan defeat switchPROTECTION 
    Mains                3 pole M&G 5 amp D curve MCB
    Mains incoming   3 x 5 Amp fuses
    Mains out going   1 x 5 amp fuse                                                           SPECIFICATIONSRLC PANELTHREE PHASE MULTI TAP 
    TRANSFORMER TRAINERTHREE PHASE MULTI TAP 
    TRANSFORMER TRAINER 
    						
    							SPECIFICATIONS
    The Star Delta Motor control Panel has been designed to operate with both 380V 
    and 220V motors. The components are rated as follows:
    CIRCUIT BREAKER: Triple pole 10A D curve motor breaker.
    MAIN FUSES: 10A fuses.
    FUSE CARRIDGE HOLDER: 16A heavy duty.
    BINDING POSTS: 20A continuous rating
    TIMER AND CONTACTOR COILS: 220V 50Hz
    RELAYS COIL: 24V DC   
    TIMER AND CONTACTOR CURRENT RATING: 9A  at AC3 rating 
                                                                                      25A at AC1 rating
    RELAY CURRENT RATING: 5A 
    TIMER DURATION: 0 to 30 seconds
    OVERLOAD SETTING: 2,5 Amps to 4 AmpsSTAR DELTA MOTOR CONTROL TRAINER 
    						
    							AC SUPPLYRated input voltage        220/230 V AC
    Rated input current        300 mALine frequency               50-60 Hz
    COMPONENTS60 Va isolating transformer with variac
    AC OUTPUT
    Rated output voltage     0 - 30 V AC
    Rated output current     2 A
    PROTECTION 
    Mains                   FusedSecondary          Fuse on each tap
                    
                                               SPECIFICATIONS15-0-15 VOLT AC POWER SUPPLY 
    						
    							EQUIPMENT RACKING SYSTEMSBUILT TO SUIT CLIENTS INDIVIDUAL 
     NEEDSBuilt to suit clients individual needs. With side  
    rails, Equipment can be positioned in any manner. This system eliminates space problems and keep 
    student together in a workable group.Old an new equipment can be used together verycost effectively in the system with great results.When a piece of current equipment in the racking system become obsolete simply that piece of equipment need changing with minimum costing for brackets etc.    
    						