EDUCATIONAL EQUIPMENTP O Box 137 Parow 7499 Bellville 7530 27 21 9300929 / 32 27 21 9300934Fax:E-mail:[email protected] site:Tel:Unit 8 Boulevard Park Off Boulevard Drive Cape Town MPTRONAELECTRONICS (Pty) LtdREG. NO: 79/02792/07
Page 2
AC SUPPLYRated input voltage 220/230 V AC Rated input current 5 A Line frequency 50-60 Hz COMPONENTS1.2 K W isolating transformer with the following input taps 210, 220 and 230 volt AC. COOLING 220 v 120 square fan AC OUTPUT Variac 1.2 kW, 0 - 220 V AC Rated output voltage 0 220 V AC Rated output current 5 A DC OUTPUT Rated output voltage 0 - 220 V DCRated output current 5 A bridge rectifier 35 A...
Page 3
SPECIFICATIONSAC SUPPLYCOMPONENTS 8 x Inductors 0.01 H at 50 Hz 8 x Power resistors 1.5 Ohm 50 Watt 12 x Capacitors 16m Farad 450 V COOLING 220 v 120 square fan PROTECTION Capacitor discharge resister built in Fan 125 mA fuse Rated input voltage 380 V AC 5 wire system Rated input current 3 A Line frequency...
Page 4
RLC PANELSPECIFICATIONSAC SUPPLYAC SUPPLYRated input voltage 220 VAC Rated input current 125 mALine frequency 50-60 Hz COMPONENTSVariable inductor 400 mH at 50 Hz Variable power resistor 100 Ohm 500 Watt Capacitors selectable in 1 m Fd steps to 60 m Farad 450 V maximumCOOLING 220 v 120 square fan PROTECTION Capacitor discharge...
Page 5
SPECIFICATIONS The Star Delta Motor control Panel has been designed to operate with both 380V and 220V motors. The components are rated as follows: CIRCUIT BREAKER: Triple pole 10A D curve motor breaker. MAIN FUSES: 10A fuses. FUSE CARRIDGE HOLDER: 16A heavy duty. BINDING POSTS: 20A continuous rating TIMER AND CONTACTOR COILS: 220V 50Hz RELAYS COIL: 24V DC TIMER AND CONTACTOR CURRENT RATING: 9A at AC3 rating 25A at...
Page 6
AC SUPPLYRated input voltage 220/230 V AC Rated input current 300 mALine frequency 50-60 Hz COMPONENTS60 Va isolating transformer with variac AC OUTPUT Rated output voltage 0 - 30 V AC Rated output current 2 A PROTECTION Mains FusedSecondary Fuse on each tap SPECIFICATIONS15-0-15 VOLT AC POWER SUPPLY
Page 7
EQUIPMENT RACKING SYSTEMSBUILT TO SUIT CLIENTS INDIVIDUAL NEEDSBuilt to suit clients individual needs. With side rails, Equipment can be positioned in any manner. This system eliminates space problems and keep student together in a workable group.Old an new equipment can be used together verycost effectively in the system with great results.When a piece of current equipment in the racking system become obsolete simply that piece of equipment need changing with minimum costing for brackets etc.