Home
>
American Water Heater
>
Gas Heater
>
American Water Heater 98 Gallon 80 Thermal Efficiency UltraLow NOx Heavy Duty Commercial Gas Water Heater User Manual
American Water Heater 98 Gallon 80 Thermal Efficiency UltraLow NOx Heavy Duty Commercial Gas Water Heater User Manual
Have a look at the manual American Water Heater 98 Gallon 80 Thermal Efficiency UltraLow NOx Heavy Duty Commercial Gas Water Heater User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 32 American Water Heater manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
31October 2009 | Printed in U.S.A. | © A. O. Smith For Technical Information and Automated Fax Service, call 800-527-1953 or visit www.hotwater.com. AOSCG61170 | PAGE 1 of 1 A. O. Smith Corporation reserves the right to make product changes or im\ provements without prior notice.NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed press\ ure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage. 4. The Tank Temperature Control should be wired to and control the pump between the w\ ater heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control.SINGLE FLUE - (2 UNITS) LEGEND TEMPERAT URE & PRESSURE RELIEF VA LV EPRESSURE RELIEF VA LV ECIRCULATING PUMPTANK TEMPERAT URE CONTROLDRAIN FULL PORT BALL VA LV E TEMPERATURE GAGEWATER FLOW SWITCH CHECK VA LV E WARNING: THIS DRAW ING SHOWS SUGGESTEDPIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. FINISHED FLOOR HOT WA TER TO FIXTURES HOTCOLDH OT HOT WATER RETURN FROM FIXTURES COLD COLD WATER SUPPLY EXPANSION TANKPIPE T&P TO OPEN DRAIN PIPE T&P TO OPEN DRAIN
32October 2009 | Printed in U.S.A. | © A. O. Smith For Technical Information and Automated Fax Service, call 800-527-1953 or visit www.hotwater.com. AOSCG61180 | PAGE 1 of 1 A. O. Smith Corporation reserves the right to make product changes or im\ provements without prior notice.NOTES: 1. Preferred piping diagram. 2. The temperature and pressure relief valve setting shall not exceed press\ ure rating of any component in the system. 3. Service valves are shown for servicing unit. However, local codes shall govern their usage.4. The Tank Temperature Control should be wired to and control the pump between the w\ ater heater(s) and the storage tank(s). 5. The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control.SINGLE FLUE - (2 UNITS) TWO TEMPERATURE ONE PRE-HEATER/ONE BOOSTER HEATER LEGEND TEMPERAT URE & PRESSURE RELIEF VA LV EPRESSURE RELIEF VA LV ECIRCULATING PUMPTANK TEMPERAT URE CONTROLDRAIN FULL PORT BALL VA LV E TEMPERATURE GAGEWATER FLOW SWITCH CHECK VA LV E WARNING: THIS DRAW ING SHOWS SUGGESTEDPIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. FINISHED FLOORHOT WA TER TO FIXTURES HOT WATER RETURN HOT HOT COLD HIGH TEMPERATURE RETURN HIGH TEMPERATURE OUTLET COLD WATER SUPPLY EXPANSION TANK PIPE T&P TO OPEN DRAIN PIPE T&P TO OPEN DRAIN BOOSTERHEATER
35 LIMITED WARRANTY EFFECTIVE For 3 Years, in the event of a tank leak, we will repair or, at our discretion, replace the defective water heater. For 1 Year , in the event of part failure, we will repair or , at our discretion, replace the defective part. We warrant this product against defects in materials or workmanship as described in this document if installed within the United States or Canada and provided the product remains at its original place of installation. W arranty coverage begins the date of installation OR the date of WHATS COVERED Subject to these terms, in the event of defect in materials and/ or workmanship resulting in a tank leak during the years, we will: Replace the water heater should the tank leak . Subject to these terms, in the event of a defect in materials and/or workmanship appearing during the , we will: Repair or, at our discretion, replace any part of the water heater covered under this limited warranty excluding parts s ubject to normal maintenance (Example: non-electroni c Service/labor, shipping, delivery, installation, handling or any other costs are not covered at any time under this warranty. Any replacement part or product will be warranted only for the unexpired portion of the original water heater ’s limite d warranty period. If an identical model is no longer available due to a change in law , regulation, or standard, we will replace the product with one having comparable capacity and input. In these instances, the owner will have the option of paying the difference between what was paid for the original model and the new model with the additional features, or receiving a refund of the portion of the purchase price, on a pro-rata basis allocable to the unexpired portion of the warranty. WHA TS NOT COVERED Problems caused by improper: gas supply line sizing, gas type, venting, connections, combustion air , voltage, wiring, or fusing Failure to follow applicable codes Failure to follow printed instructions Improper installation, sizing, deliver y, or maintenance Claims related to rust, noise, smell, or taste of water Failure to conduct authorized factory start up if required Alterations to the water heater Non-outdoor heaters installed outdoors Damages due to a failure to allow for thermal expansion Heat exchanger failure due to lack of adequate / proper supply of water Heaters moved from their original location Service trips to explain proper installation, use, or maintenance of the product/unit or to describe compliance requirements under applicable codes and regulations Charges related to accessing your heater including but not limited to door/wall removal, equipment rental, etc. Replacement parts after expiration of this warranty LIMIT ATIONS NOTWITHST ANDING ANYTHING ELSE TO THE CONTRA RY, . Y T N A R R A W E V I S U L C X E D N A E L O S R U O Y S I S I H T AL L OTHER WARRANTIES INCLUDING A WA RRANTY OF MERCHANT ABILITY OR FITNESS FOR PART ICULAR P URPOSE ARE EXPRESS LY DISCLAIMED. SELLER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, SPECIAL, PUNITIVE OR OTHER INDIRECT DAMAGES. TO TAL LIABILITY ARISING AT AN Y TIME SHALL NO T EXCEED THE PURCHASE PRICE PAID WHETHER BASED ON CONTRACT, TORT, STRICT LIABILITY OR ANY OTHER LEGAL THEO RY. SERVICE INQUIRIES: For service inquiries call the telephone number listed below. Be prepared to provide the following information : name, address, and telephone number; the model and serial number of the water heater; proof of installation; and a clear descri ption of the problem. For your records, fill in the product: Serial: __________________ _ Model: ___________________ U.S. Customers: American Water Heaters 500 Princeton Road Johnson City , TN 37605 800-999-9515 www.americanwaterheaters.com COMMERCIAL WA TER HE ATER LIMITED W ARRANTY
36 P.O. Box 1597, Johnson City, TN 37605 Phone: 800-456-9805 • Fax: 800-999-5210 www.americanwaterheater.com Copyright © 2015 American Water Heater Company. All rights reserved.www.americanwaterheate r.co m American Wa ter Heater Johnson Cit y, TN 37605