Altek TechChek Model 830KP Manual
Here you can view all the pages of manual Altek TechChek Model 830KP Manual. The Altek manuals for Calibrator are available online for free. You can easily download all the documents as PDF.
Page 2
1 Your New TechChek 830-KP Lighten your load…take the TechChek 830-KP to every site. It’s like bringing a cartload of test equipment from the shop to the control room or the field. The TechChek 830-KP sources and reads DC like a milliamp or voltage calibrator, simulates and measures T/Cs & RTDs like a temperature calibrator, generates and counts frequency and Counts-Per- Minute like a frequency calibrator and displays pressure like a precision test gauge. Troubleshooting? It checks continuity with a...
Page 3
3 GENERAL TURN-ON Each time you turn on the TechChek 830-KP it runs through a self check then returns to the most recently selected settings. SOURCE - The three QUIK-CHEK outputs will be the same as previously stored. Each time a different function is selected, the associated three QUIK-CHEK outputs will be recalled. READ - The 830-KP is ready to measure the same signal as the last time it was used and automatically updates the MAX & MIN readings for recall at any time. CONNECTIONSTechChek 830-KP has...
Page 4
5 GENERAL CONFIGURING TEMPERATURE SCALESThe thermocouple and RTD ranges may be configured for full time use of °C, full time use of °F or selectable °C and °F operation. This configuration is part of the DEFAULT SETTINGS below. AUTO-OFFTechChek 830-KP can be set up to turn itself off after 30 minutes of inactivity. The internal timer is reset to 30 minutes each time a pushbutton is pressed. DEFAULT SETTINGS TechChek 830-KP may be restored to the factory default setting. This will reset the HI and LO...
Page 5
GENERAL SELECTING FUNCTIONS Press a function key to choose among mA, V, T/C, Ω, RTD, FREQ and PRESSURE. SELECTING RANGESPress the RANGE/TYPE pushbutton to select the desired range and scale. SOURCE RANGESMilliamp: Source: mA, %mA (% 4-20), DP% (% Differential Pressure) 2-Wire Simulator: mA, %mA (% 4-20), DP% (% Differential Pressure) VDC: mV, V T/C: Types J, T, E, K, N, R & S in °C &°F Ohms: Ohms RTD: Four Pt 100Ω, Ni 120Ω& Cu 10Ωin °C &°F Frequency: KHz, Hz, CPM READ RANGESMilliamp: mA, %mA (% 4-20),...
Page 6
9 CALIBRATE MILLIAMP INPUTS mA, mA % (Percent of 4 to 20 mA), DP% (DP Flow) Choose this function to provide an output from 0.00 to 24.00 milliamps. The compliance voltage is a nominal 24 VDC to provide the driving power to your milliamp receivers. 1) Disconnect one or both input wires from the device to be calibrated. 2) Press the MILLIAMP/V push-button until mA or mA and % appear on the display 3) Press the DISPLAY/SOURCE/READ push-button until SOURCE or 2-WIRE appear on the display 4) If 2-WIRE is on...
Page 7
11 CALIBRATE VOLTAGE INPUTS V, m V Choose this function to provide an output from 0.00 mV to 110.00 mV and from 0.00 to 10.25 VDC. Current compliance up to 20 mA to provide the driving power to your voltage receivers. 1) Disconnect one or both input wires from the device to be calibrated 2) Press the MILLIAMP/V push-button until V or mV appear on the display 3) Press the DISPLAY/SOURCE/READ push-button until SOURCE and V or mV appear on the display 4) Press the TYPE/ENG UNITS push-button once to switch...
Page 8
13 CONTROLLER (TYPICAL) ADDITIONAL 4-20 mA OR 1-5V INSTRUMENTS RECORDER COMPUTER LOGGER ETC, 1-5V DC 250Ω Typical 2-Wire Transmitter +IN- REF +OUT- CHECK 1-5 VOLT INPUTSWITHOUT DISCONNECTING WIRES OPERATING INSTRUCTIONS 12 CHECK 1-5 VOLT INPUTSWITHOUT DISCONNECTING WIRESMost 1-5 Volt receivers in 4-20mA loops have a 250 Ohm resistor across the input of the receiver. This resistor may be mounted internally or externally. TechChek 830-KP is connected directly across the input of the 1-5 Volt receiver...
Page 9
15 CALIBRATE RESISTANCE INPUTSChoose this function to simulate a resistance into a variety of instruments. 1) Disconnect one or both input wires from the device to be calibrated 2) Press the T/C/RTD/Ωpushbutton until the Ωsymbol appears on the display. 3) Press the DISPLAY/SOURCE/READ push-button until SOURCE appears on the display 4) Connect the red SOURCE lead of the calibrator to the plus (+) input of the device and the black SOURCE lead to the minus (-). Output resistance is continuously adjustable...
Page 10
17 OPERATING INSTRUCTIONS Instrument withRTD Input Controller Temperature Transmitter Temperature Indicator Temperature Trip or Alarm Receiver InputOhms or 2-Wire RTD Controller Transmitter Computer Three Wire RTD Connection Two Wire RTD Connection CALIBRATE RTD INPUTS Four Wire RTD Connection SENSOR} + COMP - COMP Jumper Jumper 16 CALIBRATE RTD INPUTSChoose this function to simulate a temperature signal into any instrument requiring an RTD input. 1) Disconnect the RTD from the instrument being...