39 38 SPECIFICATIONSSOURCE RTD & OHMS RTD TYPES: Pt 100Ωfor 1.3850 (DIN/IEC 751 & New JIS), 1.3902 (Burns), 1.3926 (US Lab) & 1.3916 (Old JIS 1604C-1981) Ni 120Ωand Cu 10Ω RTD RESOLUTION:1°C or 1°F RANGE OHMS: 0.0 to 400.0 Ohms ACCURACY:±0.05% of Full Scale + 0.075 mV/mA Excitation Current ACCURACY OHMS: ±(0.05% of 400.0 Ohms + 0.1 Ohm = ±0.3 Ohms (At 1 mA Excitation Current) TEMPERATURE EFFECT:±((0.035 mV/°C)*(1/mA Excitation Current)) ALLOWABLE EXCITATION CURRENT: 0.125 to 2.0 mA continuous DC READ RTD RTD TYPES & RESOLUTION: Same as for SOURCE RTD RTD RANGE (IN OHMS): 0.0 to 400.0 Ohms RTD ACCURACY (OHMS): ±(0.05% of 400.0 Ohms + 0.1 Ohm = ±0.3 Ohms EXCITATION CURRENT SUPPLIED:1 mA, nominal FREQUENCY SOURCE R ANGES: 1 to 1500 CPM (Count-Per-Minute); 1 to 1500 Hz, 0.01 to 15.00 kHz ACCURACY: ±(0.05% of 1500 CPM + 1 CPM) = ±2 CPM ±(0.05% of 1500 Hz + 1 Hz) = ±2 Hz ±(0.05% of 15.00 kHz + 0.01 kHz) = ±0.02 kHz OUTPUT WAVEFORM:Square Wave, Zero Crossing, -1V to +5V ±10% RISETIME:Hz 1 Meg Ohm to 10.25V, >5 Meg Ohm to 200V SOURCE RESISTANCE EFFECT: 0.01% per 100 Ohms SOURCE THERMOCOUPLES THERMOCOUPLE TYPES: J, K, T, E, N, R & S RESOLUTION:1°C or 1°F ACCURACY: °C ±(0.05% OF 80 MV + 1°C); °F ±(0.05% OF 80 MV + 1°F) COLD JUNCTION ACCURACY: ±1°C COLD JUNCTION EFFECT: within 0.05°C per °C change OUTPUT IMPEDANCE:10 mA, MaxREAD THERMOCOUPLES THERMOCOUPLE TYPES & ACCURACY: Same as for SOURCE T/C RESOLUTION: 0.1°C or 0.1°F COLD JUNCTION ACCURACY: ±1°C COLD JUNCTION EFFECT: within 0.05°C per °C change INPUT IMPEDANCE:> 1 Meg Ohm OPEN THERMOCOUPLE DETECTION: 450 millisecond pulse. Nominal threshold, 10 K Ohms. READ OHMS RANGE OHMS: 0.0 to 1000.0 Ohms ACCURACY: ±(0.05% of 1000.0 Ohms + 0.1 Ohm) = ±0.6 Ohms EXCITATION CURRENT SUPPLIED:1 mA, nominal CONTINUITY CHECKING TEST CURRENT:Nominal 1 mA THRESHOLD:100 Ohm ±20% INDICATION:Steady tone & Symbol on LCD plus Ohm Reading
41 40 THERMOCOUPLE SPECIFICATIONS THERMOCOUPLE SPECIFICATIONS T/C TYPEJ K T E °C °F RANGE ACCURACY RANGE ACCURACY 100 to 1200 ±1.7 212 to 2192 ±2.3 -50 to 99 ±1.8 -58 to 211 ±2.5 -150 to -49 ±2.2 -238 to -57 ±3.2 -200 to -149 ±2.8 -328 to -237 ±4.3 1100 to 1372 ±2.2 2012 to 2500 ±3.1 0 to 1099 ±2.0 32 to 2011 ±2.9 -100 to -1 ±2.3 -148 to 31 ±3.3 -200 to -99 ±3.6 -328 to -147 ±5.7 200 to 400 ±1.7 392 to 752 ±2.4 0 to 199 ±1.9 32 to 391 ±2.7 -100 to -1 ±2.4 -148 to 31 ±3.5 -200 to -99 ±3.5 -328 to -147 ±5.6 250 to 1000 ±1.5 482 to 1832 ±2.0 50 to 249 ±1.6 122 to 481 ±2.1 -100 to 49 ±1.9 -148 to 121 ±2.6 -200 to -99 ±2.6 -328 to -147 ±3.9T/C TYPE N R S °C °F RANGE ACCURACY RANGE ACCURACY 300 to 1300 ±2.1 572 to 2372 ±3.0 100 to 299 ±2.3 212 to 571 ±3.3 -50 to 99 ±2.6 -58 to 211 ±4.0 -200 to -49 ±5.0 -328 to -57 ±8.2 1750 to 1768 ±4.2 3182 to 3214 ±6.9 950 to 1749 ±4.0 1742 to 3181 ±6.5 650 to 949 ±4.4 1202 to 1741 ±7.2 300 to 649 ±5.1 572 to 1201 ±8.4 1700 to 1768 ±4.9 3092 to 3214 ±8.0 1050 to 1699 ±4.4 1922 to 3091 ±7.1 700 to 1049 ±4.8 1292 to 1921 ±7.8 300 to 699 ±5.4 572 to 1291 ±8.9 Note: Thermocouple accuracies are based on an 80.00 mV Span T/C Accuracy for °C is ±(0.05% of 80.00 mV + 1°C) T/C Accuracy for °F is ±(0.05% of 80.00 mV + 1°F) Source resolution is 1 °C or °F. Read resolution is 0.1 °C or °F
43 42 RTD SPECIFICATIONS QuikCal 90 MODULE SPECIFICATIONS RTD TYPE ALPHA °C RANGEACCURACY Pt 100Ω(DIN/IEC/JIS 1989) 1.3850 -100 to 850 ±1 Pt 100Ω(Burns) 1.3902 -100 to 648 ±1 Pt 100Ω(Old JIS 1981) 1.3916 -100 to 648 ±1 Pt 100Ω(US Lab) 1.3926 -100 to 862 ±1 Ni 120Ω1.6720 -80 to 273 ±1 Cu 10Ω1.4274 -200 to 260 ±8 RTD TYPE ALPHA °F RANGEACCURACY Pt 100Ω(DIN/IEC/JIS 1989) 1.3850 -148 to 1562 ±2 Pt 100Ω(Burns) 1.3902 -148 to 1200 ±2 Pt 100Ω(Old JIS 1981) 1.3916 -148 to 1200 ±2 Pt 100Ω(US Lab) 1.3926 -148 to 1584 ±2 Ni 120Ω1.6720 -112 to 524 ±2 Cu 10Ω1.4274 -328 to 500 ±1 RTD resolution is 1 °C or °F. OPERATING TEMPERATURE:-10°C TO 50°C (13°F TO 122°F) STORAGE TEMPERATURE:-40°C TO 85°C (-40°F TO 185°F) WEIGHT:0.4 kg (14.5 oz) TEMPERATURE EFFECT:None (Compensated over full range) CONNECTION:1/8” NPT FEMALE See Quik-Cal 90 Module manual for available modules and additional specifications
44 WARRANTY Altek products are warranted to be free from defects in material and workmanship (excluding fuses, batteries and leads) for a period of three years from the date of shipment. Warranty repairs can be obtained by returning the equipment prepaid to our factory. Products will be replaced, repaired, or adjusted at our option. Altek gives no other warranties, including any implied warranty of fitness for a particular purpose.Also, Altek shall not be liable for any special, indirect, incidental or consequential damages or losses arising from the sale or use of its products. ORDERING INFORMATION Part No. 830 TechChek 830 Process Calibrator Included with each Model 830 are: Deluxe Carrying Case with hands free shoulder strap and zippered pocket for lead kits Test Lead Kit
PN 1886520 Rev A April 2002 ©2002 Altek Industries, Inc. Specifications subject to change without notice. All rights reserved. Printed in U.S.A.