Home > Albrecht > Communications receiver > Albrecht AX400/AE500 H First Edition Owners Manual

Albrecht AX400/AE500 H First Edition Owners Manual

Here you can view all the pages of manual Albrecht AX400/AE500 H First Edition Owners Manual. The Albrecht manuals for Communications receiver are available online for free. You can easily download all the documents as PDF.

Page 1

AX400 / AE 500 H First Edition
Owner’s Manual
Thank you for purchasing our receiver
For proper use of this receiver, please read this manual thoroughly.
Keep this manual in a safe place for future reference.
WARNING
l Do not use any batteries other than size AA Alkaline or manganese batteries. Using different batteries could
cause fire, electric shock or failure.
l Do not place consumed batteries in a fire. They could explode, causing fire or burns.
l Do not install or remove batteries while your hands...

Page 2

l Never disassemble the receiver.  Never touch the receiver’s core.
l It is adjusted for optimum performance.
l Avoid hot places and locations exposed to direct sunlight.
l Avoid extremely cold places.
l Avoid exposing the receiver to excessive vibrations and dusty places.
l Applicable batteries are either AA-size manganese or alkaline batteries.   Never use any other batteries.
l This receiver require 2.2 to 3.5 volts DC.
l This receiver is capable of receiving AM, FM Narrow Band (Amateur Radio bands,...

Page 3

by the POWER key. Please take out the batteries and replace them!
Adjusting the Volume To increase the volume, turn the VOL knob clockwise.      (Illust. 8) To decrease the volume, turn the VOL knob counterclockwise.  (Illust. 7)
CAUTIONl Set the volume to an acceptable loudness level.  Be sure to decrease the volume level before switching from
built-in speaker to earphones.
Adjusting the SquelchWhen a signal is not being received, a noise is emitted. The Squelch adjustment eliminates this noise.  Also...

Page 4

 (Illust. 13-2) Hold down FUNC key and press POWER key.
  (A high pitched beep is emitted). Release the keys and confirm if the original state is displayed in the display.   (Illust. 13-3)
Resetting the All Settings  (All Reset)
With following procedure, your receiver is set at factory’s original setting. Use this function only when it is necessary
such event as CPU is locked up. All channel memories will be lost and rewritten to factory settings. Refer to the table
below for detail factory setting....

Page 5

l Pressing this key while the FUNC key is pressed activates the light.
  2 MODE Key
l Enters numeric „2“.
l Pressing this key while the FUNC key is pressed changes the reception Mode from AM to FM or to FM
Wide.
  3 SEARCH Key
l Enters numeric „3“.
l Pressing this key while the FUNC key is pressed initiates the Search stand-by state.
  4 MY/ Key
l Enters numeric „4“.
l Pressing this key while the FUNC key is pressed changes the Set Mode function stored in the My Key.
l Pressing this key while the FUNC...

Page 6

 Confirm the display. If M is displayed, press CLEAR PROGRAM key.
  (When ‘M’ is displayed, you are in the Channel Memory Mode. ) Use rotary selector to change the frequency up or down to confirm you are in FREQ Mode.
Changing the FrequencyThere are three methods for changing the frequency, 1) using rotary elector,  2) using the 5 key or ENT key while the
FUNC key is pressed, and 3) using the numeric keys.
Before changing the frequency, confirm you are in FREQ Mode by pressing CLEAR PROGRAM key.
The...

Page 7

How to Recall the Channel Memory [1]The frequencies that have previously been programmed into channel memories can be recalled by using following
method.
Using the selector Hold down FUNC key and press 7 FREQ/CH key to set to the channel memory mode.
 (Illust. 18) Turning the Selector in the clockwise direction to increase the channel memory address number.  Turning
counterclockwise to decrease the channel memory address number.
Using the 5(Up) or ENT (Down) key Hold down FUNC key and press 7 FREQ/CH key...

Page 8

4. To complete this procedure, press CLEAR PROGRAM key.
Note:
l All the contents of channel memories are cleared during All Reset procedure even when this function is
activated.
l This function does not apply to protect Search Pass Channel Memories.
Erasing Channel Memories by Block at a TimeChannel Memory can be cleared by blocks.  A block of channel memory is made up of 100 channel memory
addresses grouped consecutively.  The relationship between the block number and the channel memory addresses
are...

Page 9

Search and Scan FunctionSearch and Scan Functionl In the Expanded Mode, in order to search for the desired frequencies, Search and Scan functions are provided.
A Dual Watch function is also provided where a specific frequency can be received alternately with a frequency
stored in channel memory.
 
l The Search function has three different types.
All Search (‘39)Searches the entire band.
One Touch Search (‘39)Searches between two frequencies written to Search Band Channel Memory.
Program Search...

Page 10

Using a One Touch SearchIn this mode, you are able to set upper and lower limits of frequencies to be searched between. The 10 sets
frequencies (20 frequencies) are already preprogrammed in 20 Search Band Channel Memories Set the unit to the FREQ Mode by pressing CLEAR PROGRAM key. Hold down FUNC key and press 3 SEARCH key.  (SEArCH is displayed.) Press corresponding numeric key to select a desired search band listed below. The unit starts searching the
specified band immediately.  (Illust.28) To end,...