Page 11

11 
WIRING 
See the Installation Manual for more information. 
Batteries: 
Use only 3.0 volt Lithium Type 123 batteries (or equiva-
lent).  Two (2) batteries of this type are needed. 
 
BATTERY REPLACEMENT 
When a valid code is entered and the batteries are weak, 
the red & green LEDs will light and the sounder will sound 
for 4 seconds.  Replace with two (2) 3.0 volt Lithium Type 
123 batteries.  Always replace weak batteries as soon as 
possible. 
CAUTION:  Do not press any keys while batteries are...

Page 12

12 
Quick Start 
First Time Start Up 
1.   Unpack the lock. 
2.   With the batteries disconnected, hold down the ; key for 10 seconds and release. 
3.   Connect the batteries and listen for 3 beeps.   
4.   Wait 15 seconds, and listen for 6 additional beeps (LED will flash twice).  The lock is ready to program when it 
unlocks.   
      Important Note:  When entering any key sequence below, do not pause more than 25 seconds between any key 
presses--otherwise you must start again.   
 
Enter Program Mode...

Page 13

13 
Quick Start (cont’d) 
Program the lock by pressing:  ; 2  ; 21  ; 232323  :). 
3.   Repeat step 2 for each new user. 
Delete a User Code 
1.   Enter Program Mode (if not in already). 
2.   Press ; 2 ;  [User Number]  :. 
      The lock will flash a green LED and beep continuously for 6 seconds.  When the red LED flashes, the User Code is de-
leted. 
3.   Repeat step 2 for each new User.   
 
User Code Conflicts 
Care should be taken not to program a new User Code which matches the first digits of any...

Page 14

14 
Verifying Basic Keypad User Codes 
 
Test a valid User Code: 
 
VALID CODE - The Green LED will flash momentarily and the sounder will beep a few times after a valid code is entered. 
INVALID CODE - The RED LED will flash several times and the sounder will beep several times after an invalid code is entered.  
Use Function 2 to re-program the code. 
 
Verifying Prox Card and Keyfob Access 
 
Test a programmed ProxCard® or ProxKey® Keyfob: 
 
Present the Programmed ProxCard
® (or Keyfob ) to the Prox...

Page 15

15 
Function 1 Change Master Code See page 16 
Function 2 Add/Delete/Change User Codes See page 16 
Function 3 User Disable (By User Number) See page 17 
Function 4 User Enable (By User Number) See page 17 
Function 5 User Enable with Timeout  See page 17 
Function 6 Enable Total User Lockout See page 17 
Function 7 Disable Total User Lockout See page 17 
Function 8 Reserved -- 
Function 9 Enable User 300 (Service Code) See page 17 
Function 10 Erase All Users Except the 
Master Code See page 17...

Page 16

16 
1. New Master Code (User Number 1) 
2. Add/Delete/Change User Codes 2-2000  
; 1      ; [ _ _ _ _ _ _ ]           ; [ _ _ _ _ _ _ ] : 
   (New Master Code)                  (Confirm New Master Code) 
; 2      ; [ _ _ _ _ ]  *              ; [ _ _ _ _ _ _ ] : 
(User Number)                                    (User Code) 
•User Number must be between 2 and 2000. 
•To delete a code/card, leave the User Code blank and wait for the rapid beeping to stop. 
•User Code must be 3-6 digits. 
•Each User Code...

Page 17

17 
USERS (Continued) 
; 6 :  6. Enable Total User Lockout Mode (This Function enabled through keypad only) 
7. Disable Total User Lockout Mode (This Function enabled through keypad only) 
; 7 : 
User Lockout Mode  
Prevents all User Codes (Except User 1 Code) from operating the lock.  Note: No other programming 
functions or schedules will re-enable Users.  Users must be re-enabled with Function 7. 
Note:  Does not change the User enable/disable status.  Note:  If the lock is currently in Passage Mode...

Page 18

18 
; 1 2      ; 0 0 0 :  12. Clear All Schedules and Timeout Functions 
Function 12 clears all programmed Schedules and all Timeout Functions.  (To clear All Timeout Functions only, see 
Function 13 below).  Function 12 will clear all of the following:  All Schedule Functions 72 through 93, Timeout Functions 
5, 25 through 34 and Function 47.  Note:  Function 12 also resets Passage Mode and any disabled Groups.  After using 
Function 12, your Scheduled/Timeout features must be manually re-programmed....

Page 19

19 
GROUPS 
Group Enable/Disable with Timeout (Enter Timeout, XXX Hours) (Functions 25-34 are enabled through the keypad only) 
•Hours must be between 1-999.  Enter the functions below to Enable/Disable Groups for the amount of time entered in hours. 
         NOTE:   Only 4 Timeout Functions are allowed at any one time.  An error beep will sound when attempting to program more than 
4 Timeout Functions.  Functions 25 - 34 will each override existing scheduled events.  Therefore, Functions 25 - 34 are...

Page 20

20 
; 3 8      ; [ _ _ _ _ _ _ ] :  
  
(Date) 
38. Set Date 
•Use Month Day Year format - MMDDYY - Single digit months and days are entered with a preceding zero. 
•Enter ONLY the last two digits of the year. 
 
For Example: March 8, 2002; Enter:  
 ; 3 8      ; 0 3   0 8    0 2 : 
 3 
39. Set Time ; 3 9      ; [ _ _ _ _ ] :  
  
(Time) 
•Time must be 4 digits 
•Use 24 Hour Format (add 12 hours to program PM time) 
 
For Example:  To set time to 8:25PM;  
 
 
 
Enter: ; 3 9      ; 2 0 2 5 :  For...