Page 21
21 CLOCK ADJUST ; 4 3 ; [ _ _ ] : (seconds) 43. Speed Up Clock (This Function enabled through keypad only) ; 4 4 ; [ _ _ ] : (seconds) 44. Slow Down Clock (This Function enabled through keypad only) Number of seconds to adjust (speed up/slow down) the clock each day must be be- tween 0-55 seconds. Note: Repeated use of these Functions are not cumulative (this means, for example, if the clock has already been set to speed up 10 seconds per day, and then is found to need...
Page 22
22 49. Disable Permanent Passage Mode (This Function enabled through keypad only) 50. Return Lock to Normal Passage Mode Schedule (This Function enabled through keypad only) (Locks will lock or unlock depending on the current schedule). Use Function 50 to undo Functions 48 and/ or 49, and therefore return the lock to all pre-existing scheduled functions. •Function 48 allows passage through the door without the need for a User Code. Re-Lock using Function 49. •Programmed Schedules will not...
Page 23
23 ; 5 5 : ; 5 7 : 57. Print Clock Settings, Software Version and Door Number 55. Print Audit Trail ; 5 6 : 56. Print User Code List ; 5 8 : 58. Upload/Download PC Data Hold the printer over the locks infrared sensor as shown in Figure 1 and Figure 2 above. Twenty (20) events will print at a time; press 1 for more events, or 9 to quit. To abort printing, press any key for 3 seconds (three short beeps will sound). Hold the printer over the locks infrared sensor as shown in Figure 1 and...
Page 24
24 60. Number of Attempts Before Lockout 61. Set the Attempts Lockout Time •Number of attempts before lockout must be 1-9 attempts. •The number of attempts is reduced by half every time the keypad is locked out without a successful code entry (default is 6 attempts). •The attempt count is reset each time a valid code is entered. •Lockout Time must be 1-60 seconds. How long the keypad is locked-out after a series of unsuccessful attempts (default is 18 seconds). 4 4 LOCKOUT ; 6 0 ;...
Page 25
25 Scheduled Passage and Group Use the functions below to enable Passage Mode and enable/disable Groups at the time programmed. •For day enter: 1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday, 7 for Saturday, 8 for Monday to Friday, 9 for Saturday and Sunday, and 0 for all days of week. SCHEDULES 74. Schedule Enable Group 1 ; 7 4 ; [ _ ] ; [ _ _ _ _ ] : (Day) (Time) 75....
Page 26
26 QUICK SCHEDULES 84. Business Quick Schedule 7AM-5PM, Monday - Friday (This Function enabled through keypad only) ; 8 4 ; [ _ ] : (Group) ; 8 5 ; [ _ ] : (Group) 85. Day Quick Schedule 7AM-5PM, All days (This Function enabled through keypad only) ; 8 6 ; [ _ ] : (Group) 86. Evening Quick Schedule 3PM-1AM, All days (This Function enabled through keypad only) ; 8 7 ; [ _ ] : (Group) 87. Night Quick Schedule 11PM-9AM, All days (This Function enabled through...
Page 27
27 ; 9 9 ; 0 0 0 : 99. Clear All Lock Programming (This Function enabled through keypad only) Clears all programming, and returns lock to factory default settings. Audit Trail contents are maintained. M CLEAR ALL PROGRAMMING 94 - 98. Reserved 92. Enable Group 4 (Open Time Window) (This Function enabled through keypad only) ; 9 2 ; [ _ ] ; [ _ _ _ _ ] : (Day) (Time) Functions 92 and 93 allow you...
Page 28
28 Groups and Scheduled Group 1 Examples The following examples detail the more advanced features of the PDL series locks. Although all features and device functions can be programmed using the lock keypad, when programming becomes more complex you may find it easier to use DL-Windows software to program your Alarm Lock security lock. For more information, contact your Alarm Lock security professional. Assign a User to Two Groups Create a User 101 (all Users 101-150 are members of Group 2 by...
Page 29
29 Groups and Scheduled Group 1 Examples (contd.) Functions 92/93: Use Function 92 and 93 (see page 27) to create a window of time where if any Group 1 User Code is entered within the programmed window, Group 4 Users will be enabled. 1. Enter Program Mode (if not in already). 2. Using Function 2, create User 4 with a User Code of 456789: Press ; 2 ; 4 ; 4 5 6 7 8 9 :. 3. Because User 4 does not have a default Group association, make User 4 a member of Group 1 using Function 35:...
Page 30
30 Function Number(s) Function Name Programming 43/44 Clock Adjust 52/53/54 Pass Time (3 sec) † 10 sec † 15 sec † 60 Set Lockout Attempts 61 Set Lockout Time 69/70 Enter Key Enable † (Disable) † +/- 0-55 (0) (0) Seconds 1-9 Attempts (6) 1-60 seconds (1) (8) Default Values are shown in parentheses.