Page 21

21 
ALARM LOCK SYSTEMS, INC 
VERSION DL26 org REC 
04/07/06 13:11:28 Tue 
Clock adjust setting +0 
Cycle count hex 00000E 
F39 day ct  hex     00 
04/07/06 13:06:35 Tue  
USER 
ENABLED ? 
           | 
USER|USER | |GROUP|PROG 
NUM |CODE | |     |SETS 
   1 123456  E  ....   46525 
  12 987     E  ....   .... 
  13 246     E  ....   .... 
; 5 5 : 
; 5 7 : 57. Print Clock Settings and Software 
Version
 
55. Print Audit Trail  
; 5 6 :  56. Print User Code List  
; 5 8 : 58. Upload/Download PC Data 
Hold...

Page 22

22 
60. Number of Attempts Before Lockout  
61. Set the Attempts Lockout Time 
•Number of attempts before lockout must be 1-9 attempts. 
•The number of attempts is reduced by half every time the keypad is locked out without a 
successful code entry (default is 6 attempts).   
•The attempt count is reset each time a valid code is entered. 
•Lockout Time must be 1-60 seconds.  This functions defines how long the keypad is 
locked out after a series of unsuccessful attempts (default is 15 seconds).  
 4 
 4...

Page 23

23 
; 6 9 : 69. Enable : as Enter Key  
Enter Key Enable/Disable (Allows Programming of Codes that Match the 1st digits of other Codes)  
; 7 0 : 70. Disable : as Enter Key 
•When enabled, the user must press : after a User Code entry, allowing User Codes 
to be subsets of other User Codes.  For example: 
 
 
1 2 3 : is a valid User Code;  
1 2 3 4 : is also a valid User Code 
 4 
ENTER KEY 
71. Reserved 
Programming Functions (contd) 
; 6 7    ; [ _ _ ] : 
        (Event Number) 67. Add Relay Features...

Page 24

24 
72. Schedule Enable Passage 
Mode (Unlock)
 
; 7 2      ; [ _ ]           ; [ _ _ _ _ ] : 
                                          (Day)                               (Time) 
Use the functions below to Enable/Disable Schedule Passage Mode. 
For day enter: 1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thurs-day, 6 for Friday, 7 for Saturday, 8 for Monday to Friday, 9 for Saturday and Sunday, 0 for all days of week. 
Scheduled Passage Mode Enable/Disable 
73. Schedule Disable...

Page 25

25 
; 8 5      ; [ _ ] :      
                                         (Group) 
; 8 7      ; [ _ ] :      
                                         (Group) 
; 8 6      ; [ _ ] :      
                                         (Group) 
84. Business Quick Schedule 
7AM-5PM, Monday - Friday 
; 8 4      ; [ _ ] :      
                                         (Group) 
QUICK SCHEDULES 
85. Day Quick Schedule  
7AM-5PM, All days 
86. Evening Quick Schedule 
3PM-1AM, All days 
87. Night Quick Schedule...

Page 26

26 
90. Relay Activation  
(Open Time Window)
 
; 9 0      ; [ _ ]           ; [ _ _ _ _ ] : 
                                          (Day)                                      (Time) 
Scheduled Relay Activation (Group 1 Activated)  
; 9 1      ; [ _ ]           ; [ _ _ _ _ ] : 
                                          (Day)                                       (Time) 
92. Enable Group 4  
(Open Time Window)
 
 
; 9 2      ; [ _ ]           ; [ _ _ _ _ ] :...

Page 27

27 
Groups and Scheduled Group 1 Examples  
The following examples detail the more advanced features of the DL3000 lock.  Although all features and device functions can be programmed 
using the lock keypad, when programming becomes more complex you may find it easier to use DL-Windows software to program your Alarm Lock 
security lock.  For more information, contact your Alarm Lock security professional. 
 
Assign a User to Two Groups 
Create a User 101 (all Users 101-150 are members of Group 2 by...

Page 28

28 
Groups and Scheduled Group 1 Examples (contd.) 
Functions 90/91:  Use Function 90 and 91 (see page 26) to create a window of time where if any Group 1 User Code is entered within the 
programmed window, a Relay will be activated for 2 seconds.   
 
1.    Enter Program Mode (if not in already). 
2.    Connect Relay to a device to be activated. 
3.    Using Function 2, create User 4 with a User Code of 456789: 
Press ; 2 ; 4 ; 4 5 6 7 8 9 :. 
4.    Because User 4 does not have a default Group...

Page 29

29 
Function 
Number(s) Function Name 
40/41 Daylight Savings Time Enable/
Disable Enable [  ]    Disable [  ]    (Enable)  
43/44 Clock Adjust    
51/52/53 Pass Time 3-5 sec [  ]    10 sec [  ]    15 sec  [  ]  (3-5 sec) 
60 Number of Attempt Before Lockout    
61 Set the Attempts Lockout Time   
64/65 Remote Input Disable/Enable Enable [  ]    Disable [  ]    (Enable) 
 
66 Ambush Code   
67 Add Relay Function [  ] 1.      Remote Input switch closed and Function 65 
Remote Input enabled.   
[  ] 2....

Page 30

30 
User Number 
(1-300) User Code  
(3-6 digits) Group  
Association Full Name 
       1 2 3 4 1 2 3 4...