    When a valid code is entered and the batteries are weak, the 
    red & green LEDs will light and the sounder will sound for 4 
    seconds.  The DL1200 uses two 123 Type Lithium batteries 
    (Duracell P/N CR17345).  The lock will function with weak 
    batteries; however be sure to replace them as soon as 
    possible. 
     If the DL1200 is ever without power for less than 1 minute 
    (such as when replacing batteries), the DL1200 will continue its 
    operation undisturbed--programming remains unaffected due 
    to power provided by capacitors inside the lock.  If the DL1200 
    is without power for greater than one minute, you have two 
    choices--you can (1) retain the lock programming or (2) erase 
    all programming.  If you choose to erase all programming, the 
    DL1200 will revert to its original factory default configuration 
    (out of the box). 
     CAUTION:  Do not press any keys while batteries are dis-
    connected unless you intend to erase all programming.    1.Insert key in cylinder and turn counterclockwise to al-
    low access to the battery compartment screw.  With the 
    supplied 5/64 Allen wrench, loosen the battery cover 
    screw only until the battery cover is able to slide off.   
    2.Pull out the battery pack and quickly replace both 
    batteries - within 1 minute. 3.If you do not hear the 3 beeps when power is re-
    applied, all programming and settings have been re-
    tained, and the lock is ready for use.  Go to step 5. 
    4.If you do hear 3 beeps when power is re-applied, do 
    not press any keys for 15 seconds.  After the 15 
    second period, the LED will flash red 6 times and 6 
    beeps will sound.  Reset the clock using functions 38, 39 
    and 40.   
    5.Slide the battery cover back in place and tighten the 
    screw. 
     If you accidentally press a key (or fail to replace the batteries 
    within 1 minute), use the Retain Lock Programming proce-
    dure below: 
     
    Retain Lock Programming 
    1.    Re-install battery pack. 
    2.    Do not press any keys for 10 seconds. 
     If you do not hear any beeps or if you hear 3 beeps (one 
    per second), the previous lock programming is retained and 
    the lock is now ready for use.  If you test the DL1200 and 
    find the lock programming is lost, you may erase all pro-
    gramming and return the DL1200 to its original factory set-
    tings, as described below. 
    Battery Replacement 
    Erase All  Programming 
    RESTORE FACTORY DEFAULT (original out of box settings 
    that were set at the factory will be loaded). 
    1.  Enter the current Master Code (if not known, proceed di-
    rectly to ALTERNATIVE METHOD, below).  Wait for the 
    green light and press ; until multiple beeps are heard.  
    You are now in Program Mode. 
    2.  Within 5 seconds (or current pass time interval), 
    press ; 99 ; 000 :. 
    3.  Listen for 6 beeps.  The lock will re-lock.  All settings and 
    programming have been erased.  Proceed directly to page 
    12, Quick Start, and follow the procedure Enter Program 
    Mode and Change Factory Master Code. 
     
    ALTERNATIVE METHOD 
    Note:  This method requires the lock first be removed from 
    the door. 
    1.  Insert key in cylinder and turn counterclockwise to al-
    low access to the battery compartment screw.  With the 
    supplied 5/64 Allen wrench, loosen the battery cover 
    screw only until the battery cover is able to slide off.   
    2.  Disconnect the battery pack.   
    3.  Remove the back plate by unscrewing the two Phillips 
    head screws.  Note:  Some models have four Phillips 
    head screws.  Be careful not to damage the motor drive 
    wires.   
    4.  Locate jumper header JP1 near the top of the printed 
    circuit board and install the jumper (provided) across pins 
    1 and 2 of JP1. 
    5.  Press and hold down ; for 10 seconds (to ensure all power is drained from the lock) and release. 
    6.  Connect the batteries and--within 5 seconds--press 
    and hold ;.  After hearing 6 additional beeps, re-
    lease ;.  If you do not hear these 6 additional 
    beeps, you must start over at step 2.  Failure to follow 
    this exact procedure can result in erratic lock behavior.   
    7.  Test by pressing the default Master Code of 
    123456 (a beep will sound 
    and the lock will unlock). 
    8.  Remove the jumper from JP1 pins 1 and 2 and place 
    jumper on 1 pin for storage.   
    9.  Carefully reinstall the back plate STRAIGHT onto the 
    lock body.  Be careful not to pinch or damage the motor 
    drive wires.  While inserting the back plate, be sure the 
    rear pin of the tailpiece inserts into the spindle hole--
    check this alignment after installation by pushing on the 
    spring-loaded tailpiece to verify that it smoothly moves 
    up and down.  Replace the two (or four) Phillips head 
    screws to secure the back plate.  Note:  It may be nec-
    essary to tighten the battery screw previously loosened 
    in step 1.   
    10. Re-mount the lock on the door.  With the battery 
    back inside its compartment, slide the battery cover 
    back in place and tighten the screw.   
          All  settings  and  programming  have  been  erased.    Pro-
    ceed directly to page 12, Quick Start, and follow the 
    procedure Enter Program Mode and Change Fac-
    tory Master Code.  
    						
    							12 
    ALARM LOCK SYSTEMS, INC. (ALARM LOCK) 
    warrants its products to be free from manufacturing 
    defects in materials and workmanship for 24 months 
    following the date of manufacture. ALARM LOCK will, 
    within said period, at its option, repair or replace any 
    product failing to operate correctly without charge to 
    the original purchaser or user. 
    This warranty shall not apply to any equipment, or 
    any part thereof, which has been repaired by others, 
    improperly installed, improperly used, abused, altered, 
    damaged, subjected to acts of God, or on which any 
    serial numbers have been altered, defaced or 
    removed. Seller will not be responsible for any 
    dismantling or reinstallation charges. 
    THERE ARE NO WARRANTIES, EXPRESS OR 
    IMPLIED, WHICH EXTEND BEYOND THE 
    DESCRIPTION ON THE FACE HEREOF. THERE IS 
    NO EXPRESS OR IMPLIED WARRANTY OF 
    MERCHANTABILITY OR A WARRANTY OF 
    FITNESS FOR A PARTICULAR PURPOSE. 
    ADDITIONALLY, THIS WARRANTY IS IN LIEU OF 
    ALL OTHER OBLIGATIONS OR LIABILITIES ON 
    THE PART OF ALARM LOCK. 
    Any action for breach of warranty, including but not 
    limited to any implied warranty of merchantability, must 
    be brought within the six months following the end of 
    the warranty period. IN NO CASE SHALL ALARM 
    LOCK BE LIABLE TO ANYONE FOR ANY 
    CONSEQUENTIAL OR INCIDENTAL DAMAGES 
    FOR BREACH OF THIS OR ANY OTHER 
    WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE 
    LOSS OR DAMAGE IS CAUSED BY THE SELLERS 
    OWN NEGLIGENCE OR FAULT. 
    In case of defect, contact the security professional 
    who installed and maintains your security system. In 
    order to exercise the warranty, the product must be 
    returned by the security professional, shipping costs 
    prepaid and insured to ALARM LOCK. After repair or 
    replacement, ALARM LOCK assumes the cost of 
    returning products under warranty. ALARM LOCK 
    shall have no obligation under this warranty, or 
    otherwise, if the product has been repaired by others, 
    improperly installed, improperly used, abused, altered, 
    damaged, subjected to accident, nuisance, flood, fire 
    or acts of God, or on which any serial numbers have 
    been altered, defaced or removed. ALARM LOCK will 
    not be responsible for any dismantling, reassembly or 
    reinstallation charges. 
    This warranty contains the entire warranty. It is the 
    sole warranty and any prior agreements or 
    representations, whether oral or written, are either 
    merged herein or are expressly cancelled. ALARM 
    LOCK neither assumes, nor authorizes any other person purporting to act on its behalf to modify, to 
    change, or to assume for it, any other warranty or 
    liability concerning its products. 
    In no event shall ALARM LOCK be liable for an 
    amount in excess of ALARM LOCKs original selling 
    price of the product, for any loss or damage, whether 
    direct, indirect, incidental, consequential, or otherwise 
    arising out of any failure of the product. Sellers 
    warranty, as hereinabove set forth, shall not be 
    enlarged, diminished or affected by and no obligation 
    or liability shall arise or grow out of Sellers rendering 
    of technical advice or service in connection with 
    Buyers order of the goods furnished hereunder. 
    ALARM LOCK RECOMMENDS THAT THE ENTIRE 
    SYSTEM BE COMPLETELY TESTED W EEKLY. 
    Warning: Despite frequent testing, and due to, but 
    not limited to, any or all of the following; criminal 
    tampering, electrical or communications disruption, it is 
    possible for the system to fail to perform as expected. 
    ALARM LOCK does not represent that the product/
    system may not be compromised or circumvented; or 
    that the product or system will prevent any personal 
    injury or property loss by burglary, robbery, fire or 
    otherwise; nor that the product or system will in all 
    cases provide adequate warning or protection. A 
    properly installed and maintained alarm may only 
    reduce risk of burglary, robbery, fire or otherwise but it 
    is not insurance or a guarantee that these events will 
    not occur. CONSEQUENTLY, SELLER SHALL HAVE 
    NO LIABILITY FOR ANY PERSONAL INJURY, 
    PROPERTY DAMAGE, OR OTHER LOSS BASED 
    ON A CLAIM THE PRODUCT FAILED TO GIVE 
    WARNING. Therefore, the installer should in turn 
    advise the consumer to take any and all precautions 
    for his or her safety including, but not limited to, fleeing 
    the premises and calling police or fire department, in 
    order to mitigate the possibilities of harm and/or 
    damage. 
    ALARM LOCK is not an insurer of either the property 
    or safety of the users family or employees, and limits 
    its liability for any loss or damage including incidental 
    or consequential damages to ALARM LOCKs original 
    selling price of the product regardless of the cause of 
    such loss or damage. 
    Some states do not allow limitations on how long an 
    implied warranty lasts or do not allow the exclusion or 
    limitation of incidental or consequential damages, or 
    differentiate in their treatment of limitations of liability 
    for ordinary or gross negligence, so the above 
    limitations or exclusions may not apply to you. This 
    Warranty gives you specific legal rights and you may 
    also have other rights which vary from state to state. 
    Alarm Lock Limited Warranty  
    						
    All Alarm Lock manuals Comments (0)

    Related Manuals for Alarm Lock DL1200 Programming Instructions User Manual