Page 21

 Products, Inc. 
                                                           Maintenance Manual 
 
 
21-50-02 
May 15/95 Page1 
 PLUMBING 
 
DESCRIPTION AND OPERATION 
 
1. GENERAL 
 
The plumbing system consists of a flexible nylon lined refrigerant hose with 
permanent swaged on fittings.  All connections are tube O-ring type with sealant on 
the fitting mating surfaces to ensure leak free operation.  Hose, O-ring material, and 
sealant are specially designed to work with refrigerant R134a and polyol...

Page 22

 Products, Inc. 
                                                           Maintenance Manual 
 
 
 
21-50-02 
May 15/95
 Page 201 
MAINTENANCE PRACTICES 
 
1. GENERAL 
 
The following procedures are used to perform typical maintenance on the air 
conditioning system plumbing. 
 
2.  TOOLS AND EQUIPMENT 
 
 
Designation  
Ref. No.  
Qty  
Remarks 
 
 
R134a Compatible Hose Swaging 
Kit  
Available from 
Keith Products  
1  
None 
 
Sharp Knife  
Comm. Avail.  
1  
None 
 
Impact Wrench  
Comm. Avail....

Page 23

 Products, Inc. 
                                                            Maintenance Manual 
 
 
21-50-02 
May 15/95
 Page 202 
 
B.  Connection to Components - O-Ring Replacement 
1.  Place the appropriate o-ring (REF. IPL Fig. 1) over the tube O end of the 
fitting.   
2.  Lubricate o-ring with polyol ester oil or sealant prior to assembly. 
3.  Apply sealant to all fitting mating surfaces prior to assembly. 
 
C. Receiver/Drier Replacement 
1.  Replace receiver/drier whenever the compressor is...

Page 24

 Products, Inc. 
                                                            Maintenance Manual 
 
 
21-50-02 
May 15/95
 Page 601 
 
INSPECTION/CHECK 
 
1. GENERAL 
 
The following procedures are used for checking and inspecting the air conditioning 
system plumbing. 
 
2.  TOOLS AND EQUIPMENT 
 
 
Designation  
Ref. No.  
Qty  
Remarks 
 
 
Electronic R134a Refrigerant Leak 
Detector  
Comm. Avail.  
1  
None 
 
 
3.  PLUMBING CHECK PROCEDURES  (REF. IPL Fig. 1) 
 
A   Plumbing Installation Preventive...

Page 25

 Products, Inc. 
                                                         Maintenance Manual 
 
 
21-50-02 
May 15/95
 Page 1001 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 1.  Plumbing System  

Page 26

 Products, Inc. 
                                                           Maintenance Manual 
 
21-50-02 
May 15/95 Page 1002 
 
FIG. ITEM  
 PART 
 NUMBER  
 NOMENCLATURE  
 EFFECT  
 UNITS  
 PER  
 ASSY 
 
1 1 
2 
3 
4 
- 
- 
 
- 
- 
- 
- 
 
- 
- 
- 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
25 
26 
27 
28 
29 
30 
31 
32 
33 
34 
35  
82-02-105-5,-6 
JBS5005-1 
JBS2030-3 
JBS2048-3 
88-00-431-1 
MS21919WDG
12 
MS20365-1032 
AN960-10 
NAS221-10 
MS21919WDG
9 
ES06022-1 
ES02162-2 
MS3367-7 
JBS10-64...

Page 27

 Products, Inc. 
                                                            Maintenance Manual 
 
21-50-03 
May 15-95 
Page 1 
 DESCRIPTION AND OPERATION 
 
1. GENERAL 
 
The compressor/condenser assembly is located either forward of the rear baggage 
door; or in the baggage compartment.  This unit consists of a drive motor, 
compressor, condenser fan assembly, condenser coil, and pressure switch.  The 
drive motor via a multi V flat belt, turns the compressor which compresses the 
refrigerant gas at...

Page 28

 Products, Inc. 
                                                           Maintenance Manual 
 
 
21-50-03 
May 15/95 
Page 101 
 TROUBLESHOOTING 
 
1. GENERAL 
 
The following procedures are used for troubleshooting the comp/cond assembly. 
 
2.  TOOLS AND EQUIPMENT 
 
 
Designation  
Ref. No.  
Qty  
Remarks 
 
 
Service Pressure Gauge  
Comm. Avail.  
1  
None 
 
28vdc Source  
  
A/R  
None 
 
3.  COMP/COND TROUBLESHOOTING PROCEDURES (REF. IPL Fig. 1) 
 
With the air conditioning system operating,...

Page 29

 Products, Inc. 
                                                           Maintenance Manual 
 
21-50-03 
May 15/95 
Page 102 
  Trouble
       Probable Cause   Correction 
5.  Low air flow across 
condenser coil. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Dirty condenser coil.  Clean condenser coil.  

Page 30

 Products, Inc. 
                                                            Maintenance Manual 
 
21-50-03 
May 15/95 
Page 201 
 MAINTENANCE PRACTICES 
 
1. GENERAL 
 
The following procedures are used to perform typical maintenance on the 
compressor/condenser assembly. 
 
2.  TOOLS AND EQUIPMENT 
 
 
Designation  
Ref. No.  
Qty  
Remarks 
 
 
Feeler Gage  
Comm. Avail.  
1  
None 
 
Oil Dipstick  
Make from metal 
wire.  
1  
See Fig. 201. 
 
Coil Cleaner  
Comm. Avail.  
A/R  
Non Acid Based...