Products, Inc. Maintenance Manual 21-50-00 May 15/95 Page 1 AIR CONDITIONING SYSTEM - SYSTEM DESCRIPTION 1. GENERAL The air conditioning system for the Cessna 500 series aircraft consists of a refrigerant R134a vapor cycle cooling system. This system allows the co-pilot to control cooling for a comfortable aircraft cabin. Figure 1 shows a general arrangement of the air conditioning system. The co-pilots control panel...
Page 12
Products, Inc. Maintenance Manual 21-50-00 May 15/95 Page 2 An evaporator/blower unit is located in the aft cabin at the end of the recessed isle (at floor level) within the aircraft interior. It provides cooling airflow for the cabin area of the interior. A forward evaporator is located at the cockpit floor and provides cooling airflow to the flight crew through a floor mounted air outlet or through dedicated ducting at the pilots...
Page 13
Products, Inc. Maintenance Manual 21-50-00 May 15/95 Page 3 Figure 1. Air Conditioning System General Arrangement
Page 14
Products, Inc. Maintenance Manual 21-50-01 May 15/95 Page 1 ELECTRICAL DESCRIPTION AND OPERATION 1. GENERAL The air conditioning system consists of one high energy compressor/condenser drive motor and two centrifugal evaporator blowers (Fwd) and (Aft). The system is controlled by a mode switch with Air Conditioning Off and Fan Only position. Each evaporator has a high and low position switch. A blue...
Page 15
Products, Inc. Maintenance Manual 21-50-01 May 15-95 Page 101 TROUBLESHOOTING 1. GENERAL The following procedures are used for troubleshooting the electrical system and the electrical interfaces with the other assemblies of the air conditioning system. 2. TOOLS AND EQUIPMENT Designation Ref. No. Qty Remarks Service Pressure Gauge Comm. Avail. 1 None Multi-meter Comm. Avail. 1 None 28vdc...
Page 16
Products, Inc. Maintenance Manual 21-50-01 May 15/95 Page 102 7. Check for power at motor . If power is present, proceed to step 8. If power is not present on either pin and load/shed conditions of step 4 are met, check power on the load shed unit at connector Pin 1. If power is present, system problem exists in load shed system start unit. If power is not present, check 15 amp CB (3) and mode switch (26). 8. Fault is...
Page 17
Products, Inc. Maintenance Manual 20-50-01 May 15/95 Page 103 5. Remove blower assy from aircraft. Remove the four screws attaching the motor to the housing. Using a 1/8 allen wrench remove blower wheel (use extreme care not to bend blower wheel). Cut power wires at splice and remove Gnd wire from GND terminal. Install new motor in reverse order. E. AFT Evaporator Blower will not operate in the low speed setting. 1....
Page 19
Products, Inc. Maintenance Manual 21-50-01 May 15/95 Page 1002 FIG. ITEM PART NUMBER NOMENCLATURE EFFECT UNITS PER ASSY 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 82-02-106 JBS11001-1 MS3320-15 MS25361-100 ES32036-1 JBS5005-1 JBS2030-3 JBS2048-3 MS25181-2 MS25036-101 ES50162-1 MS25036-125 MS25036-157 MS25036-123 Electrical...
Page 20
Products, Inc. Maintenance Manual 21-50-01 May 15/95 Page 1003 FIG. ITEM PART NUMBER NOMENCLATURE EFFECT UNITS PER ASSY 15 16 17 18 21 22 23 24 25 26 MS25036-106 MS25036-108 84-00-07-8 ES57016-3 ES53010-3 MS25036-124 MS25036-156 ES55077-2 ES57016-6 ES57016-5 Terminal Terminal Load Shed Assy Switch Connector Terminal Terminal...