    Connection wiring diagram (details) 
    Connecting to the master station
    Procedure
    Detach the terminal cover by removing the two 1 screws.
    Connect the wiring from the sub stations and power 2 supply to the master station by inserting lead wires to 
    the corresponding terminals
    .
    Using the cable tie is recommended for secure installation.
    10mm
    (7/16”)
    After the connections for the whole system have 3 been completed, turn on the power switch.
    The power indicator on the operation panel lights up.
    POWER
    Attach the terminal cover with the two screws.4 
    ■ Note about connecting a PC to the master station.
    Use the included RS232C cable for the connection.TX RX I-GTX RX I-G
     CAUTION
    ■ Note about connecting the power supply unit(s) to the master station.
    When using the * master station, 60-call or 80-call, two power supply units are needed.
          NIM-20B/NIM-40B                                                             Master station, 60-call/80-call
    DC48V
    DC48V
    DC48V
     Do not connect 
    the two power 
    supply units in 
    parallel.
    Terminal cover
    Press the “I” side. Master station rear
    Release 
    button
    Screw
    Lights up green.
    Power supply unit 
    (IS-PU only)RS232C 
    terminalRS232C cable (1m (3.3)) 
    (provided with NI-SOFT) * Install NI-SOFT on the PC 
    from the included CD-ROM. 
    Refer to the instruction 
    manual for NI-SOFT for 
    details.  
    * When extending the RS232C cable, the distance between the master station and the PC should 
    be 15m (50) or less.  PC
    RedBlack White
    Cable tie 
    						
    							22
    Multiple-user room examples of using the ceiling speaker (NI-LB) and the ceiling 
    microphone (NI-SB)
    Black
    OrangeWhiteGrayOrange/
    White
    BlueYellowRed
    Gray
    White
    Blue
    BlueBlack
    Blue
    Blue
    Blue
    Blue
    Blue
    Blue
    Blue
    or
    Black
    Brown
    or
    EM
    Green lead 
    wire Corridor light, 
    single bed 
    (NIR-4) Master station
    Corridor light 
    with reset 
    button (NIR-42)
    Call reset 
    button 
    (NIR-2)
    Ceiling 
    speaker 
    (NI-LB)
    Ceiling 
    microphone
    (NI-SB) Wall jack 
    for NIR-8 
    (NIR-1)
    Bedside call switch 
    (NIR-8)
    Call button 
    (NIR-6)Corridor light 
    with buzzer 
    (NIR-4BZ)
    Individual channel line 
    1
    , 2, 3, etc.
    When using a corridor light and reset button
    Cut the green lead 
    wire and insulate 
    its ends.
    (6 wall jacks or 
    call buttons can be 
    connected in total.)
    When not using a corridor light, do not cut the * 
    green lead wire, and insulate the blue lead 
    wire.
    Do not cut.
    Green lead 
    wire
    ■ Meanings of symbols
     : Wire-to-wire connection
     : The wire should be cut and insulated.
    Refer to page 29, when * 
    using the corridor light 
    with nameplate (NIR-31, 
    NIR-32, NIR-34). 
    						
    							23
    APPENDIX
    MOUNTING CONNECTION GETTING STARTED
    SETUP AFTER 
    INSTALLATION
    Multiple-user room examples of using the ceiling speaker (NI-LB) and not using the ceiling 
    microphone (NI-SB)
    Black
    OrangeWhiteGrayOrange/
    White
    BlueYellowRed
    Blue
    BlueBlack
    Blue
    Blue
    Blue
    or
    Black
    Brown
    or
    EM
    Gray WhiteBlue Blue
    Individual channel line 
    1
    , 2, 3, etc.
    Corridor light, 
    single bed 
    (NIR-4)Corridor light 
    with reset button 
    (NIR-42)
    Call reset 
    button 
    (NIR-2)
    Ceiling 
    speaker 
    (NI-LB)
    Wall jack with 
    microphone 
    for NIR-8 
    (NIR-MB)
    Bedside call switch 
    (NIR-8)Corridor light 
    with buzzer 
    (NIR-4BZ)
    Cut the green lead 
    wire and insulate 
    its ends. Master station
    Green lead 
    wire
    (6 wall jacks with 
    microphone can be 
    connected in total.)
    When not using a corridor light, do not cut the * 
    green lead wire, and insulate the blue lead 
    wire.
    Do not cut.
    Green lead 
    wire
    When using a corridor light and reset button
    ■ Meanings of symbols
     : Wire-to-wire connection
     : The wire should be cut and insulated.
    Refer to page 29, when * 
    using the corridor light 
    with nameplate (NIR-31, 
    NIR-32, NIR-34). 
    						
    							24
    Multiple-user room examples of using the bedside handheld sub stations (NI-RC) etc.
    E
    M
    BrownBlack
    OrangeRed
    Yellow
    E
    M
    NI-RC NIR-HP
    NIR-HPF
    Blue
    Blue
    Blue
    Blue
    NIR-7W or 
    NIR-7HW
    (*1)
    CALL
    Black
    RedBlue Green(*1)Black
    Yellow
    RedBlue
    Black
    Yellow
    RedBlue Green(*1)Green
    NI-RC
    NI-RC
    (*1)Black
    RedBlue GreenBlack
    Yellow
    RedBlue(*1)GreenBlack
    Yellow
    RedBlue(*1)Green
    Individual 
    channel line 
    1
    , 2, 3, 
    etc.
    When using the corridor light, multiple beds (NIR-4S) and call reset button (NIR-2)
    Individual 
    channel line 
    1
    , 2, 
    3
    , etc.
    Wall jack 
    for NI-RC 
    (NIR-HP)Wall jack 
    with hanger 
    for NI-RC 
    (NIR-HPF)Bathroom 
    call button 
    (NIR-7W or 
    NIR-7HW) Bedside 
    handheld 
    sub station 
    (NI-RC)Corridor light with 
    nameplates, 4 
    names 
    (NIR-34)
    * Refer to page 29 
    for the detailed 
    connection method 
    for the corridor light 
    with nameplate 
    (NIR-34, NIR-32 
    and NIR-31).
    Corridor 
    light, 
    multiple 
    beds 
    (NIR-4S)
    Call reset 
    button 
    (NIR-2)
    (*1): When using a corridor light; 
      Cut the connection between 
    the black and green wires to 
    separate them, and insulate the 
    green wire.
    (*1): When using a corridor light; 
      Cut the connection between 
    the black and green wires to 
    separate them, and insulate the 
    green wire. Master station
    Master station
    Green
    Black
    Green
    Black
    ■ Meanings of symbols
     : Wire-to-wire connection
     : The wire should be cut and insulated. 
    						
    							25
    APPENDIX
    MOUNTING CONNECTION GETTING STARTED
    SETUP AFTER 
    INSTALLATION
    E
    BrownBlack
    OrangeRed
    YellowBlack
    Orange
    RedBlue Green(*1) (*2)
    E
    M
    NIR-7W or 
    NIR-7HWNI-RC NIR-HP
    (*3)
    (
    *4)Black
    Yellow
    Red Red
    Blue GreenBlackBlue Green
    (*3)
    (
    *4)
    Individual 
    channel line 
    1
    , 2, 3, 
    etc.
    When not using a corridor light  
    Call latching wall 
    jack for NIR-8 
    (NIR-7BS)
    Bedside call switch 
    (NIR-8)
    Master station
    (*3): When not using a corridor light; 
      Do not cut the connection between 
    the black and green wires. 
    Insulate the blue lead wire.
    When using equipment without microphone (no communication is possible)
    Individual 
    channel line 
    1
    , 2, 3, 
    etc.
    Corridor light with nameplates, 
    4 names (NIR-34)
    * Refer to page 29 for the 
    detailed connection method 
    for the corridor light with 
    nameplate (NIR-34, NIR-32 
    and NIR-31).(*1): When using a corridor light; 
      Cut the connection between 
    the black and green wires to 
    separate them, and insulate the 
    green and orange lead wire.
    (*2): The orange lead wire should be insulated. Master station
    Green
    Black
    Green
    Black
    (*4): The blue lead wire should be insulated. 
    						
    							26
    Examples of using the bathroom call buttons (NIR-7W or NIR-7HW)
    Blue
    Blue
    Blue
    Blue
    NIR-7W
    NIR-7W
    or NIR-7HWCALL
    or NIR-7HWCALL
    orCALL
    CALL
    CALL
    E
    NIR-7W NIR-7W
    NIR-7W
    (*2)
    (*3)
    (
    *3)
    (
    *3)
    CALL
    CALL
    E
    Red
    Black
    Blue
    Green
    CALL
    Red
    Black
    Blue
    Green
    Red
    Black
    Blue
    GreenRed
    Black
    Blue
    Green
    CALL
    Red
    Black
    Blue
    Green
    Red
    Black
    Blue
    Green
    Black
    BlueBlack
    Brown
    oror
    (*1)
    (*1)
    (*1)
    (*2)
    (
    *2)
    Individual channel line 
    1
    , 2, 3, etc.
    Individual channel line 1
    , 2, 3, 
    etc.
    When using a corridor light and reset button
    When not using a corridor light 
    Corridor light, 
    single bed 
    (NIR-4)
    Bathroom 
    call button 
    with pull 
    cord 
    (NIR-7HW)Bathroom 
    call button 
    (NIR-7W)Corridor light 
    with reset 
    button (NIR-42) Corridor light 
    with buzzer 
    (NIR-4BZ)
    Call reset 
    button 
    (NIR-2) Master station
    Master station
    Up to 3 bathroom call buttons can be connected to a single * 
    channel line.
    (*1): When using a corridor 
    light; 
      Cut the connection 
    between the black and 
    green wires to separate 
    them, and insulate the 
    green wire.
    Green
    Black
    (*2): When not using 
    a corridor light; 
      Do not cut the 
    connection 
    between the black 
    and green wires. 
    Insulate the blue 
    lead wire.
    Green
    Black
    ■ Meanings of symbols
     : Wire-to-wire connection
     : The wire should be cut and insulated.
    Refer to page 29, when * 
    using the corridor light with 
    nameplate (NIR-31, NIR-32, 
    NIR-34).
    (*3): The blue lead wire 
    should be insulated. 
    						
    							27
    APPENDIX
    MOUNTING CONNECTION GETTING STARTED
    SETUP AFTER 
    INSTALLATION
    Single room examples of using the surface mount sub station (NI-BA)
    Blue Blue
    Blue
    Blue
    E
    I IC
    CE
    CS M A
    Blue
    Blue
    EM
    or
    E
    I IC
    CE
    CS M A
    (*1)
    (
    *2)
    Black Blue
    Black Brownoror
    When using a corridor light and reset button
    Individual channel line 
    1
    , 2, 3, etc.
    When not using a corridor light
    Corridor light, 
    single bed 
    (NIR-4)Corridor light 
    with reset 
    button (NIR-42) Corridor light 
    with buzzer 
    (NIR-4BZ)
    Call reset 
    button 
    (NIR-2)
    Wall jack for 
    NIR-8 (NIR-1) Sub station, 
    surface mount 
    (NI-BA)
    Sub station, 
    surface mount 
    (NI-BA)
    Bedside call switch 
    (NIR-8) Call button 
    (NIR-6) Master station
    Refer to page 29, when using * 
    the corridor light with nameplate 
    (NIR-31, NIR-32, NIR-34).
    (*1): Remove the lead wire between the CE and 
    CS terminals. 
      The CS terminal is not used.
    (*2): Do not remove the 
    lead wire between 
    the CE and CS 
    terminals. 
      The C terminal is 
    not used.
    ■ Meanings of symbols
     : Wire-to-wire connection 
    						
    							28
    Examples of using the fl ush mount sub station (NI-JA)
    Blue Blue
    Blue
    Blue
    EM
    E
    C
    CE
    CS M A
    E
    C
    CE
    CS M A
    (*1)
    (
    *2)
    Black Blue
    Black Brownoror
    Individual channel line 
    1
    , 2, 3, etc.
    When using a corridor light and reset button
    When not using a corridor light
    Call reset 
    button 
    (NIR-2)
    Sub station, 
    fl ush mount 
    (NI-JA)Sub station, 
    fl ush mount 
    (NI-JA) Master station
    Corridor light, 
    single bed 
    (NIR-4)Corridor light 
    with reset 
    button (NIR-42) Corridor light 
    with buzzer 
    (NIR-4BZ)
    Refer to page 29, when using the * 
    corridor light with nameplate (NIR-
    31, NIR-32, NIR-34).
    (*1): Remove the lead wire between the CE and 
    CS terminals. 
      The CS terminal is not used.(*2): Do not remove the lead wire between 
    the CE and CS terminals. 
      The C terminal is not used.
    ■ Meanings of symbols
     : Wire-to-wire connection 
    						
    							29
    APPENDIX
    MOUNTING CONNECTION GETTING STARTED
    SETUP AFTER 
    INSTALLATION
    Notes about connecting to a corridor light with nameplate (NIR-31, NIR-32, NIR-34)
    The individual user displays and the corresponding lead wire colors are as follows.
    When the call button of a sub station connected to one of the color-coded lead wires of the corridor light is pressed, the corresponding 
    number of the call indicator lights.
                       NIR-31                                                    NIR-32                                                      NIR-34
    11
    21
    23
    4
    Individual 
    user displayColor of 
    lead wireIndividual 
    user displayColor of 
    lead wireIndividual 
    user displayColor of lead wire
    1Brown1Brown1Brown
    2Red2Red
    3Orange
    4Yellow
    Wiring example
    BrownBlack
    Black
    Yellow OrangeRed
    Red Yellow
    Blue GreenBlack
    Yellow
    RedBlueGreenBlack
    Yellow
    RedBlueGreenBlack
    RedBlue Green1
    1
    23
    4
    2 3
    4
    BrownBlack
    Red1 2
    1
    1
    2
    BrownBlack1
    E
    M
    4
    3
    2
    1
    CALL
    (*1)(*1)(*1)
    (*1)
    Call indicator
    Individual user 
    display
    Individual 
    channel 
    line
    e.g.
    When the call button of the sub 
    station connected to the red lead 
    wire is pressed, the call indicator 
    of display 
    2 lights.
    Sub station 1Sub station 2Sub station 3Bathroom call 
    button 4Corridor light with 
    nameplates, 4 names 
    (NIR-34)
    Corridor light with 
    nameplates, 2 
    names (NIR-32) Corridor light with 
    nameplate, 1 
    name (NIR-31) Master station
    1
    23
    4Lights
    ■ Meanings of symbols
     : Wire-to-wire connection
    (*1): When using a corridor light; 
      Cut the connection between 
    the black and green wires to 
    separate them, and insulate the 
    green wire.
    Green
    Black 
    						
    							30
    SETUP AFTER INSTALLATION
    Adjusting volume and ringtone settings
    For these changes, use the switches and control knobs under the switch cover by removing the cover.
    Switch cover
    Reset button RemoveChanging the sound type of ringtone
    You can change the sound type of ringtone between melody 
    and chime. 
    To select melody, put switch 5 in UP 
    position.
    To select chime, put switch 5 in DOWN 
    position. 
    Activating/deactivating the automatic volume 
    gain of ringtone
    When this function is active, the volume of ringtone increases 
    automatically to the maximum level (low→mid→high) in a 
    90-second interval.
    To  disable, put switch 6 in UP position. 
    To  enable, put switch 6 in DOWN position.
    * 
    : Do not change these switches. They have been preset 
    in the optimum positions. 
    NOTE: After modifying the settings, press the reset 
    button to apply new settings.
    Adjusting volume
    To adjust:
    Turn the control knob clockwise to increase and 
    counterclockwise to decrease the volume.
    RECEIVE:
    This adjusts the master receive volume. As 
    the basis of this level, you can adjust the 
    receiving volume with the 
    RECEIVE VOL. tab 
    on the master station operation panel.  
    RING TONE:
    This adjusts the master volume of ringtone. 
    As the basis of this level, you can adjust the 
    ringtone volume with the 
    RING TONE VOL. tab 
    on the master station operation panel.
    TALK:
    This adjusts the volume of audio (sent from 
    the master station) heard at the sub stations.
    PRETONE:
    This adjusts the volume of notice sound 
    heard at the sub stations.
    ALL CALL:
    This adjusts the volume of all station paging 
    heard at the sub stations.
    OFF: Chime
    DecreaseON: Melody
    IncreaseOFF: Enable ON: Disable 
    						