21 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION Connection wiring diagram (details) Connecting to the master station Procedure Detach the terminal cover by removing the two 1 screws. Connect the wiring from the sub stations and power 2 supply to the master station by inserting lead wires to the corresponding terminals . Using the cable tie is recommended for secure installation. 10mm (7/16”) After the connections for the whole system have 3 been completed, turn on the power switch. The power indicator on the operation panel lights up. POWER Attach the terminal cover with the two screws.4 ■ Note about connecting a PC to the master station. Use the included RS232C cable for the connection.TX RX I-GTX RX I-G CAUTION ■ Note about connecting the power supply unit(s) to the master station. When using the * master station, 60-call or 80-call, two power supply units are needed. NIM-20B/NIM-40B Master station, 60-call/80-call DC48V DC48V DC48V Do not connect the two power supply units in parallel. Terminal cover Press the “I” side. Master station rear Release button Screw Lights up green. Power supply unit (IS-PU only)RS232C terminalRS232C cable (1m (3.3)) (provided with NI-SOFT) * Install NI-SOFT on the PC from the included CD-ROM. Refer to the instruction manual for NI-SOFT for details. * When extending the RS232C cable, the distance between the master station and the PC should be 15m (50) or less. PC RedBlack White Cable tie
22 Multiple-user room examples of using the ceiling speaker (NI-LB) and the ceiling microphone (NI-SB) Black OrangeWhiteGrayOrange/ White BlueYellowRed Gray White Blue BlueBlack Blue Blue Blue Blue Blue Blue Blue or Black Brown or EM Green lead wire Corridor light, single bed (NIR-4) Master station Corridor light with reset button (NIR-42) Call reset button (NIR-2) Ceiling speaker (NI-LB) Ceiling microphone (NI-SB) Wall jack for NIR-8 (NIR-1) Bedside call switch (NIR-8) Call button (NIR-6)Corridor light with buzzer (NIR-4BZ) Individual channel line 1 , 2, 3, etc. When using a corridor light and reset button Cut the green lead wire and insulate its ends. (6 wall jacks or call buttons can be connected in total.) When not using a corridor light, do not cut the * green lead wire, and insulate the blue lead wire. Do not cut. Green lead wire ■ Meanings of symbols : Wire-to-wire connection : The wire should be cut and insulated. Refer to page 29, when * using the corridor light with nameplate (NIR-31, NIR-32, NIR-34).
23 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION Multiple-user room examples of using the ceiling speaker (NI-LB) and not using the ceiling microphone (NI-SB) Black OrangeWhiteGrayOrange/ White BlueYellowRed Blue BlueBlack Blue Blue Blue or Black Brown or EM Gray WhiteBlue Blue Individual channel line 1 , 2, 3, etc. Corridor light, single bed (NIR-4)Corridor light with reset button (NIR-42) Call reset button (NIR-2) Ceiling speaker (NI-LB) Wall jack with microphone for NIR-8 (NIR-MB) Bedside call switch (NIR-8)Corridor light with buzzer (NIR-4BZ) Cut the green lead wire and insulate its ends. Master station Green lead wire (6 wall jacks with microphone can be connected in total.) When not using a corridor light, do not cut the * green lead wire, and insulate the blue lead wire. Do not cut. Green lead wire When using a corridor light and reset button ■ Meanings of symbols : Wire-to-wire connection : The wire should be cut and insulated. Refer to page 29, when * using the corridor light with nameplate (NIR-31, NIR-32, NIR-34).
24 Multiple-user room examples of using the bedside handheld sub stations (NI-RC) etc. E M BrownBlack OrangeRed Yellow E M NI-RC NIR-HP NIR-HPF Blue Blue Blue Blue NIR-7W or NIR-7HW (*1) CALL Black RedBlue Green(*1)Black Yellow RedBlue Black Yellow RedBlue Green(*1)Green NI-RC NI-RC (*1)Black RedBlue GreenBlack Yellow RedBlue(*1)GreenBlack Yellow RedBlue(*1)Green Individual channel line 1 , 2, 3, etc. When using the corridor light, multiple beds (NIR-4S) and call reset button (NIR-2) Individual channel line 1 , 2, 3 , etc. Wall jack for NI-RC (NIR-HP)Wall jack with hanger for NI-RC (NIR-HPF)Bathroom call button (NIR-7W or NIR-7HW) Bedside handheld sub station (NI-RC)Corridor light with nameplates, 4 names (NIR-34) * Refer to page 29 for the detailed connection method for the corridor light with nameplate (NIR-34, NIR-32 and NIR-31). Corridor light, multiple beds (NIR-4S) Call reset button (NIR-2) (*1): When using a corridor light; Cut the connection between the black and green wires to separate them, and insulate the green wire. (*1): When using a corridor light; Cut the connection between the black and green wires to separate them, and insulate the green wire. Master station Master station Green Black Green Black ■ Meanings of symbols : Wire-to-wire connection : The wire should be cut and insulated.
25 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION E BrownBlack OrangeRed YellowBlack Orange RedBlue Green(*1) (*2) E M NIR-7W or NIR-7HWNI-RC NIR-HP (*3) ( *4)Black Yellow Red Red Blue GreenBlackBlue Green (*3) ( *4) Individual channel line 1 , 2, 3, etc. When not using a corridor light Call latching wall jack for NIR-8 (NIR-7BS) Bedside call switch (NIR-8) Master station (*3): When not using a corridor light; Do not cut the connection between the black and green wires. Insulate the blue lead wire. When using equipment without microphone (no communication is possible) Individual channel line 1 , 2, 3, etc. Corridor light with nameplates, 4 names (NIR-34) * Refer to page 29 for the detailed connection method for the corridor light with nameplate (NIR-34, NIR-32 and NIR-31).(*1): When using a corridor light; Cut the connection between the black and green wires to separate them, and insulate the green and orange lead wire. (*2): The orange lead wire should be insulated. Master station Green Black Green Black (*4): The blue lead wire should be insulated.
26 Examples of using the bathroom call buttons (NIR-7W or NIR-7HW) Blue Blue Blue Blue NIR-7W NIR-7W or NIR-7HWCALL or NIR-7HWCALL orCALL CALL CALL E NIR-7W NIR-7W NIR-7W (*2) (*3) ( *3) ( *3) CALL CALL E Red Black Blue Green CALL Red Black Blue Green Red Black Blue GreenRed Black Blue Green CALL Red Black Blue Green Red Black Blue Green Black BlueBlack Brown oror (*1) (*1) (*1) (*2) ( *2) Individual channel line 1 , 2, 3, etc. Individual channel line 1 , 2, 3, etc. When using a corridor light and reset button When not using a corridor light Corridor light, single bed (NIR-4) Bathroom call button with pull cord (NIR-7HW)Bathroom call button (NIR-7W)Corridor light with reset button (NIR-42) Corridor light with buzzer (NIR-4BZ) Call reset button (NIR-2) Master station Master station Up to 3 bathroom call buttons can be connected to a single * channel line. (*1): When using a corridor light; Cut the connection between the black and green wires to separate them, and insulate the green wire. Green Black (*2): When not using a corridor light; Do not cut the connection between the black and green wires. Insulate the blue lead wire. Green Black ■ Meanings of symbols : Wire-to-wire connection : The wire should be cut and insulated. Refer to page 29, when * using the corridor light with nameplate (NIR-31, NIR-32, NIR-34). (*3): The blue lead wire should be insulated.
27 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION Single room examples of using the surface mount sub station (NI-BA) Blue Blue Blue Blue E I IC CE CS M A Blue Blue EM or E I IC CE CS M A (*1) ( *2) Black Blue Black Brownoror When using a corridor light and reset button Individual channel line 1 , 2, 3, etc. When not using a corridor light Corridor light, single bed (NIR-4)Corridor light with reset button (NIR-42) Corridor light with buzzer (NIR-4BZ) Call reset button (NIR-2) Wall jack for NIR-8 (NIR-1) Sub station, surface mount (NI-BA) Sub station, surface mount (NI-BA) Bedside call switch (NIR-8) Call button (NIR-6) Master station Refer to page 29, when using * the corridor light with nameplate (NIR-31, NIR-32, NIR-34). (*1): Remove the lead wire between the CE and CS terminals. The CS terminal is not used. (*2): Do not remove the lead wire between the CE and CS terminals. The C terminal is not used. ■ Meanings of symbols : Wire-to-wire connection
28 Examples of using the fl ush mount sub station (NI-JA) Blue Blue Blue Blue EM E C CE CS M A E C CE CS M A (*1) ( *2) Black Blue Black Brownoror Individual channel line 1 , 2, 3, etc. When using a corridor light and reset button When not using a corridor light Call reset button (NIR-2) Sub station, fl ush mount (NI-JA)Sub station, fl ush mount (NI-JA) Master station Corridor light, single bed (NIR-4)Corridor light with reset button (NIR-42) Corridor light with buzzer (NIR-4BZ) Refer to page 29, when using the * corridor light with nameplate (NIR- 31, NIR-32, NIR-34). (*1): Remove the lead wire between the CE and CS terminals. The CS terminal is not used.(*2): Do not remove the lead wire between the CE and CS terminals. The C terminal is not used. ■ Meanings of symbols : Wire-to-wire connection
29 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION Notes about connecting to a corridor light with nameplate (NIR-31, NIR-32, NIR-34) The individual user displays and the corresponding lead wire colors are as follows. When the call button of a sub station connected to one of the color-coded lead wires of the corridor light is pressed, the corresponding number of the call indicator lights. NIR-31 NIR-32 NIR-34 11 21 23 4 Individual user displayColor of lead wireIndividual user displayColor of lead wireIndividual user displayColor of lead wire 1Brown1Brown1Brown 2Red2Red 3Orange 4Yellow Wiring example BrownBlack Black Yellow OrangeRed Red Yellow Blue GreenBlack Yellow RedBlueGreenBlack Yellow RedBlueGreenBlack RedBlue Green1 1 23 4 2 3 4 BrownBlack Red1 2 1 1 2 BrownBlack1 E M 4 3 2 1 CALL (*1)(*1)(*1) (*1) Call indicator Individual user display Individual channel line e.g. When the call button of the sub station connected to the red lead wire is pressed, the call indicator of display 2 lights. Sub station 1Sub station 2Sub station 3Bathroom call button 4Corridor light with nameplates, 4 names (NIR-34) Corridor light with nameplates, 2 names (NIR-32) Corridor light with nameplate, 1 name (NIR-31) Master station 1 23 4Lights ■ Meanings of symbols : Wire-to-wire connection (*1): When using a corridor light; Cut the connection between the black and green wires to separate them, and insulate the green wire. Green Black
30 SETUP AFTER INSTALLATION Adjusting volume and ringtone settings For these changes, use the switches and control knobs under the switch cover by removing the cover. Switch cover Reset button RemoveChanging the sound type of ringtone You can change the sound type of ringtone between melody and chime. To select melody, put switch 5 in UP position. To select chime, put switch 5 in DOWN position. Activating/deactivating the automatic volume gain of ringtone When this function is active, the volume of ringtone increases automatically to the maximum level (low→mid→high) in a 90-second interval. To disable, put switch 6 in UP position. To enable, put switch 6 in DOWN position. * : Do not change these switches. They have been preset in the optimum positions. NOTE: After modifying the settings, press the reset button to apply new settings. Adjusting volume To adjust: Turn the control knob clockwise to increase and counterclockwise to decrease the volume. RECEIVE: This adjusts the master receive volume. As the basis of this level, you can adjust the receiving volume with the RECEIVE VOL. tab on the master station operation panel. RING TONE: This adjusts the master volume of ringtone. As the basis of this level, you can adjust the ringtone volume with the RING TONE VOL. tab on the master station operation panel. TALK: This adjusts the volume of audio (sent from the master station) heard at the sub stations. PRETONE: This adjusts the volume of notice sound heard at the sub stations. ALL CALL: This adjusts the volume of all station paging heard at the sub stations. OFF: Chime DecreaseON: Melody IncreaseOFF: Enable ON: Disable