Aiphone NIM Series Instructions User Manual
Have a look at the manual Aiphone NIM Series Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 MOUNTING CONNECTION GETTING STARTEDAPPENDIX SETUP AFTER INSTALLATION Ceiling speaker, ceiling microphone ■ Ceiling speaker (NI-LB) ■ Ceiling microphone (NI-SB) Main unitChinese RoHS paperMain unitWood screw (x2) 15 (9/16”) ø180 (7-1/16”) ø105 (4-1/8”) 5 (3/16”) HolderChinese RoHS paper 65 (2-9/16”) Corridor light, reset button ■ Corridor light, single bed (NIR-4) ■ Corridor light, multiple beds (NIR-4S) ■ Call reset button (NIR-2) Main unit Screw (x2) Main unit Screw (x2) 21.5 (7/8”) 120 (4-3/4”) 70 (2-3/4”) 120 (4-3/4”) 70 (2-3/4”)13 (1/2”) Chinese RoHS paperChinese RoHS paper (Front) (Front) (Side) (Side) (Front) (Front) (Side) (Side) (Side)
12 ■ Corridor light with reset button (NIR-42) Main unit Screw (x4) 120 (4-3/4”) 27 (1-1/16”) 116 (4-9/16”) Chinese RoHS paper ■ Corridor light with buzzer (NIR-4BZ) Main unit Screw (x4) 120 (4-3/4”) 27 (1-1/16”) 116 (4-9/16”) Chinese RoHS paper ■ Corridor light with nameplate, 1 name (NIR-31) Main unit Mounting bracketRoom number plateNameplate 144 (5-11/16”) 16 (5/8”) 190 (7-1/2”) 24 (15/16”) Screw (x4) Chinese RoHS paper (Front) (Front) (Side) (Side) (Front) (Side)
13 MOUNTING CONNECTION GETTING STARTEDAPPENDIX SETUP AFTER INSTALLATION ■ Corridor light with nameplates, 2 names (NIR-32) Main unit Mounting bracketRoom number plateNameplate (x2) 144 (5-11/16”) 16 (5/8”) 190 (7-1/2”) 24 (15/16”) Screw (x4) Chinese RoHS paper ■ Corridor light with nameplates, 4 names (NIR-34) Main unit Mounting bracketRoom number plateNameplate (x4) 144 (5-11/16”) 16 (5/8”) 306 (12-1/16”) 24 (15/16”)Screw (x4) Chinese RoHS paper Software ■ Call log software (NI-SOFT) CD-ROM RS232C cableProduct Key code paper/ Chinese RoHS paper (Front) (Side) (Front) (Side)
14 MOUNTING This section illustrates the mounting procedures for wall- and ceiling-mount equipment. ■ Ceiling speaker (NI-LB) ■ Ceiling microphone (NI-SB) ø105mm (4-3/16”) 66.7mm (2-11/16”) NOTE: Make sure to mount the ceiling microphone 50 cm (20) apart from the ceiling speaker to prevent audio feedback. Pay attention to the depth of the unit. Use board anchors or concrete plugs as needed on a concrete wall. Holder Hook Connector Loop Main unit Main unit SpringCeiling CeilingØ150mm (5-7/8) Disconnect the connector, 2 and then make wire connections with other equipment. Make a hole of 150mm (5-7/8) 1 in diameter in the ceiling. Put the holder into 3 the hole by tilting it, and then position it as shown. Hang the loop on the 4 hook at one side.Connect the connector to 5 the main unit. Hang the loop on the 6 hook at the other side, and install the main unit so that it is positioned at the center of the hole. Wood screw x 2 (included) Central part Cut 1 the ceiling so that the central part of the unit fi ts in. Make wire 2 connections with the other equipment. Fasten the unit to the 3 wall with the wood screws. W: 47mm (1-7/8) Opening dimensions H: 38mm (1-1/2) D: 40mm (1-9/16)
15 MOUNTING CONNECTION GETTING STARTEDAPPENDIX SETUP AFTER INSTALLATION ■ Wall jack (NIR-HP, NIR-1, NIR-MB, NIR-7BS) Call button (NIR-6) Corridor light (NIR-4, NIR-4S) Call reset button (NIR-2) The illustration shows the wall jack for NI-RC (NIR-HP).* Bathroom call button (NIR-7W, NIR-7HW) The illustration shows the bathroom call button (NIR-7W).* CALL Remove the front cover from 1 the main unit. Install a single gang box 2 in the wall. Pass the wires through the gang box and make the wire connections with the other equipment. 83.5mm (3-5/16) Single-gang box Screw x 2 (included) Main unit Front cover Fasten the unit to the single-3 gang box with the screws. Attach the front cover 4 to the main unit. Install a single gang box 2 in the wall. Pass the wires through the gang box and make the wire connections with the other equipment. 83.5mm (3-5/16) Single-gang box Screw x 2 (included)Main unit Front cover Fasten the unit to the 3 single-gang box with the screws. The screw holes are on the * backside of gray rubber. Attach the front cover to the main unit.4 CALL Remove the front cover 1 from the main unit. Insert a fl at head screwdriver into the hole on the bottom of the unit, and then pull the fl at head screwdriver toward you. The front cover opens. Flat head screwdriver Hole HD W HD W Opening dimensions without a gang box W: 45mm (1-3/4), H: 72mm (2-13/16), D: 54mm (2-1/8) Opening dimensions without a gang box W: 50mm (1-15/16), H: 70mm (2-3/4), D: 20mm (13/16)
16 ■ Sub station, surface mount (NI-BA) When mounting NI-BA on a wall, follow the procedure shown below.* ■ Sub station, fl ush mount (NI-JA) Tighten Special screw x 4 (included)46 mm (1-13/16) Loosen Hexagonal wrench (included) Opening dimensions without a gang box W: 90mm (3-9/16), H: 73mm (2-7/8), D: 54mm (2-1/8)Main unit 2-gang box Install a 2 gang box in the wall. 1 Pass the wires through the gang box and make the wire connections with the terminal cover open. Be sure to route the wires through * inlet. Inlet Terminal cover 83.5 mm (3-5/16) Fasten the main unit to 2 the gang box with the special screws. Install a single gang box in the wall. Pass the 1 wires through the gang box and make the wire connections with the other equipment. 83.5mm (3-5/16) Single-gang box Screw x 2 (included) Main unit Fasten the mounting bracket to 2 the gang box with the screws. Attach the main unit to 3 the mounting bracket. Mounting bracket (attached to NI-BA when shipped) When setting NI-BA on a desk Rubber footCable inlet plate Cable inlet Cable inlet Attach the included 4 rubber feet on the back • of NI-BA. Route the wires through the cable inlet at the • upper or lower part of NI-BA. When routing the wires at the upper part, * remove the cable inlet plate to allow passage of the wires.
17 MOUNTING CONNECTION GETTING STARTEDAPPENDIX SETUP AFTER INSTALLATION ■ Wall jack (NIR-HPF) Corridor light (NIR-42, NIR-4BZ) ■ Corridor light with nameplate (NIR-31, NIR-32, NIR-34) The illustration shows the corridor light with nameplates, 4 names (NIR-34).* Mounting bracket (attached to the unit when shipped) Main unit Screw (for gang box) × 4 (included)Single, 2- or 3-gang box Install a gang box in the wall.1 NIR-31, NIR-32: 2-gang box(*) NIR-34: 3-gang box(*) (*): Recommended Detach the mounting 2 bracket from the main unit by removing the room number plate and the screw. Fasten the mounting 3 bracket to the gang box with the screws. StringWires Gang box Main unit Hang the string of 4 the main unit on a projecting part or a thread on the bracket to suspend the main unit. Make wire connections 5 with other equipment. Screw (attached) Room number plate46 mm (1-13/16) 2-gang box Remove the front 1 cover from the main unit.Install a 2 gang box in 2 the wall. Pass the wires through the gang box and make the wire connections with the other equipment. 83.5mm (3-5/16) Screw x 4 (included) Main unit Front cover Fasten the unit to the 2-gang 3 box with the screws. Attach the front cover 4 to the main unit. The illustration shows the * corridor light with reset button (NIR-42). Screw (attached) Room number plate Mount the main unit on the 6 mounting bracket, and affi x the main unit to the bracket with the screw. Attach the room number 7 plate to the main unit Opening dimensions without a gang box W: 95mm (3-3/4), H: 75mm (2-15/16), D: 54mm (2-1/8)
18 CONNECTION Connection wiring diagram (outline) The following is an example of basic wiring diagram. The wiring methods differ depending on the equipment used. Refer to page 20 to 29 for details about various wiring methods. * E 1 M 2 3 4 5 10 12 19 20 11 SK S1 SK S1 I-G RXTX Black OrangeWhiteGrayOrange/ White BlueYellowRed Gray White PC Blue Blue Blue Blue 22 29 30 21 32 39 40 E M 31 34 33 Gray White Blue Blue Red White Black Black Yellow RedBlue or NIR-8NI-LB GreenBlack Yellow RedBlueGreenBlack Yellow RedBlueGreen NI-RC NIR-HP NI-RC NIR-HP NIR-4 NIR-2 Blue Blue Black OrangeWhiteGrayOrange/ White BlueYellowRed Blue Blue Blue BlueCorridor light, single bed (NIR-4) Call reset button (NIR-2) Ceiling speaker (NI-LB) Master station, 40-call (NIM-40B) When using the master station, 60-call or 80-call, two power supplies are needed. Do not connect two power supplies in parallel. • Master station, 20-call (NIM-20B) • Master station, 60-call (*) • Master station, 80-call(*) Call extension speaker (IER-2) Power supply unit (IS-PU only) RS232C cable (included on NI-SOFT) Ceiling microphone (NI-SB) Wall jack for NIR-8 (NIR-1) Bedside call switch (NIR-8) (6 wall jacks can be connected in total.) * Connect to each of the color-coded wires.* Connect to each of the color-coded wires. (6 wall jacks can be connected in total.) Refer to page 21 for details about wiring to a master station. Refer to page 22 for details and examples of using alternative equipment.Refer to page 23 for details and examples of using alternative equipment.Wall jack with microphone for NIR-8 (NIR-MB) Wall jack for NI-RC (NIR-HP) Bedside handheld sub station (NI-RC) (*): Special order product. N/A in North America. Speaker etc. (3W/20Ω, third party product) SP-20N/A (*) ( *): North America only (*1) ( *1)
19 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION Red Black CALLBlue Green Blue Blue Blue Blue Red Black Blue Red Black Blue CALL CALL Blue Blue Blue Blue II Blue Blue Green Green BrownBlack Black OrangeRed Red Yellow Blue Green NIR-7W or NIR-7HW NIR-7W or NIR-7HW NIR-7W or NIR-7HW Blue Blue Blue Blue E C CE CS M A NIR-4 NIR-2NIR-4 NIR-2 NIR-8NIR-1 NIR-4 NIR-2 CALL E C CE CS M A ■ Wiring distance Wire diameter Maximum distance Master station - sub stationØ0.65mm (22 AWG) Ø0.9mm (18 AWG)130m (425) 200m (650) Master station - power supply unit Ø0.9mm (18 AWG) 10m (33) Master station - call extension speaker (IER-2), speaker etc.Ø0.9mm (18 AWG) 50m (165) ■ Master station terminal marking E : Common line (for earth ground) M : Common line (for microphone) 1 ... 10, 11... : Individual channel line Refer to page 28 for details and examples of using alternative equipment. Refer to page 27 for details and examples of using alternative equipment. Refer to page 26 for details and examples of using alternative equipment. Refer to page 24-25 for details and examples of using alternative equipment. Refer to page 29 for details about wiring to the corridor light with nameplate (NIR-34, NIR-32 or NIR-31). * Up to 3 bathroom call buttons can be connected to a single channel line. Bathroom call button (NIR-7W or NIR-7HW) Sub station, surface mount (NI-BA) Sub station, fl ush mount (NI-JA) Corridor light with nameplates, 4 names (NIR-34)■ Meanings of symbols : Wire-to-wire connection : The wire should be cut and insulated. (*1): • The common line E and individual channel lines should be in the same sheath wiring. • The remainder wires in the same sheath wiring should be connected to the common line E of the master station for noise prevention.
20 Handling cables Notes about handling cables Cables and connectors are not included with the products.* ■ Notes on cables Use PE (polyethylene)-insulated PVC jacketed cable.• Parallel or jacketed conductors, mid-capacitance, non-shielded cable is recommended. Never use twisted pair cable or coaxial cable. • ■ How to connect or disconnect stranded wires. To ensure that the wire wont bend, press the release button while inserting into terminal.• 8mm(3/8") ■ Note about wire-to-wire connection. Make wire-to-wire connections securely as shown below. e.g.) NI-BA Release button From a sub stationWire nut Cable Splice 2 wires with wire nuts, securely protecting from being pulled or crushed. e.g.) NIM-40B Release button