Page 21
21 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION Connection wiring diagram (details) Connecting to the master station Procedure Detach the terminal cover by removing the two 1 screws. Connect the wiring from the sub stations and power 2 supply to the master station by inserting lead wires to the corresponding terminals . Using the cable tie is recommended for secure installation. 10mm (7/16”) After the connections for the whole system have 3 been completed, turn on the power...
Page 22
22 Multiple-user room examples of using the ceiling speaker (NI-LB) and the ceiling microphone (NI-SB) Black OrangeWhiteGrayOrange/ White BlueYellowRed Gray White Blue BlueBlack Blue Blue Blue Blue Blue Blue Blue or Black Brown or EM Green lead wire Corridor light, single bed (NIR-4) Master station Corridor light with reset button (NIR-42) Call reset button (NIR-2) Ceiling speaker (NI-LB) Ceiling microphone (NI-SB) Wall jack for NIR-8 (NIR-1) Bedside call switch (NIR-8) Call button...
Page 23
23 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION Multiple-user room examples of using the ceiling speaker (NI-LB) and not using the ceiling microphone (NI-SB) Black OrangeWhiteGrayOrange/ White BlueYellowRed Blue BlueBlack Blue Blue Blue or Black Brown or EM Gray WhiteBlue Blue Individual channel line 1 , 2, 3, etc. Corridor light, single bed (NIR-4)Corridor light with reset button (NIR-42) Call reset button (NIR-2) Ceiling speaker (NI-LB) Wall jack with microphone...
Page 24
24 Multiple-user room examples of using the bedside handheld sub stations (NI-RC) etc. E M BrownBlack OrangeRed Yellow E M NI-RC NIR-HP NIR-HPF Blue Blue Blue Blue NIR-7W or NIR-7HW (*1) CALL Black RedBlue Green(*1)Black Yellow RedBlue Black Yellow RedBlue Green(*1)Green NI-RC NI-RC (*1)Black RedBlue GreenBlack Yellow RedBlue(*1)GreenBlack Yellow RedBlue(*1)Green Individual channel line 1 , 2, 3, etc. When using the corridor light, multiple beds (NIR-4S) and call reset button (NIR-2) Individual...
Page 25
25 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION E BrownBlack OrangeRed YellowBlack Orange RedBlue Green(*1) (*2) E M NIR-7W or NIR-7HWNI-RC NIR-HP (*3) ( *4)Black Yellow Red Red Blue GreenBlackBlue Green (*3) ( *4) Individual channel line 1 , 2, 3, etc. When not using a corridor light Call latching wall jack for NIR-8 (NIR-7BS) Bedside call switch (NIR-8) Master station (*3): When not using a corridor light; Do not cut the connection between the black and green...
Page 26
26 Examples of using the bathroom call buttons (NIR-7W or NIR-7HW) Blue Blue Blue Blue NIR-7W NIR-7W or NIR-7HWCALL or NIR-7HWCALL orCALL CALL CALL E NIR-7W NIR-7W NIR-7W (*2) (*3) ( *3) ( *3) CALL CALL E Red Black Blue Green CALL Red Black Blue Green Red Black Blue GreenRed Black Blue Green CALL Red Black Blue Green Red Black Blue Green Black BlueBlack Brown oror (*1) (*1) (*1) (*2) ( *2) Individual channel line 1 , 2, 3, etc. Individual channel line 1 , 2, 3, etc. When using a corridor light and...
Page 27
27 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION Single room examples of using the surface mount sub station (NI-BA) Blue Blue Blue Blue E I IC CE CS M A Blue Blue EM or E I IC CE CS M A (*1) ( *2) Black Blue Black Brownoror When using a corridor light and reset button Individual channel line 1 , 2, 3, etc. When not using a corridor light Corridor light, single bed (NIR-4)Corridor light with reset button (NIR-42) Corridor light with buzzer (NIR-4BZ) Call reset button...
Page 28
28 Examples of using the fl ush mount sub station (NI-JA) Blue Blue Blue Blue EM E C CE CS M A E C CE CS M A (*1) ( *2) Black Blue Black Brownoror Individual channel line 1 , 2, 3, etc. When using a corridor light and reset button When not using a corridor light Call reset button (NIR-2) Sub station, fl ush mount (NI-JA)Sub station, fl ush mount (NI-JA) Master station Corridor light, single bed (NIR-4)Corridor light with reset button (NIR-42) Corridor light with buzzer (NIR-4BZ) Refer to page...
Page 29
29 APPENDIX MOUNTING CONNECTION GETTING STARTED SETUP AFTER INSTALLATION Notes about connecting to a corridor light with nameplate (NIR-31, NIR-32, NIR-34) The individual user displays and the corresponding lead wire colors are as follows. When the call button of a sub station connected to one of the color-coded lead wires of the corridor light is pressed, the corresponding number of the call indicator lights. NIR-31 NIR-32...
Page 30
30 SETUP AFTER INSTALLATION Adjusting volume and ringtone settings For these changes, use the switches and control knobs under the switch cover by removing the cover. Switch cover Reset button RemoveChanging the sound type of ringtone You can change the sound type of ringtone between melody and chime. To select melody, put switch 5 in UP position. To select chime, put switch 5 in DOWN position. Activating/deactivating the automatic volume gain of ringtone When this function is active, the volume of...