Page 11
4.5 External control interface 4.5.1 Type of external control interface 1) Digital I/O sink type 2) Digital I/O source type (under development) 3) Device Net 4) InterBus (under development) 5) Profibus (under development) Switching over to an external interface control requires an additional exclusive board and SW1 setting in the following table. SW1 setting is determined and set at the time of shipment from our factory. Be sure not to change setting of SW1. SW1-1 SW1-2 SW1-3 SW1-4...
Page 12
- 12 - 4.5.2 Digital I/O 4.5.2.1 Input signals (PLC 1) NO Signal names Connections Functions 1 Preparation NC Stop signal suspends operation 2 System reset NO Reset main unit to resume initial status 3 Reverse NO Rotate anti-clockwise only while reverse command signal is provided. 4 Stall NO Tightening signal lasting 500ms gets this function started. 5 Start NO Start tightening. 6 Cycle start NO Get one operation cycle started. 7 Cycle count up NO Count up signal from internal cycle...
Page 13
- 13 - 4.5.2.2 Output signals (PLC 2) Contents of output signals pin numbers 1-32 are for free format which is for free allocation by customers. The allocation can be made by user console. Main unit comes with dat a output bank setting 0 whose allocation table is as mentioned below (output data bank 1 to 7 are all free format (pin numbers 1 to 32). NO Signal names Connections Functions 1 TOTAL NOK NO Main unit outputs this signal when tightening result was NOK. This is output also...
Page 14
Suitable plug Manufacturer: Honda Name: Small multipolar connector PLC1: MR-34F+MR-34L (case) PLC2: MR-34M+MR-34L (case) Above comes with soldered connectors. Input and output hardware PLC2 1KΩ 2.2KΩ 2.2KΩ 1KΩ 2.2KΩ 2.2KΩ -+ 源DC24V電 PLC1 装置 PLCUト 出 出 0V 24V 入 入 EC-MAINユニッ 力信号 力信号 力信号 力信号 output signal outputsignal DC24V source input signal input signal To PLC UEC-MAIN unit - 14 -
Page 15
4.6 Timing chart ① Basic control signal STOP R R S CYCLE COUNT UP M ALA EADY ESET TART 締結動作 総合OK RUN 総合NOK RM END 締結動作締結tightening tightening STOP READY RESET START TIGHTENING OPERATION M RUN TOTAL OK TOTAL NOK ALARM END CYCLE COUNT UP ② Timing of tightening sequence signal and start ワーク選択0 STAR ワ ワ ワ ワ 20ms以後に選択指令と選択結果信号で インターロックを取って下さい。 シ シ ーケンス選択番号1 ーケンス選択番号1Sequence select 1 Sequence select 1 Give OFF and ON interval minimum 20ms to have interlock ワーク選択1 ワーク選択3 ワーク選択2...
Page 16
5 F-TYPE NUTRUNNER SYSTEM USER CONSOLE 5.1 F-TYPE NUTRUNNER SYSTEM USER CONSOLE MENE STRUCTURE File Load All Files Save All Files ---------------------- Open Parameter Save Parameter ---------------------- Open Sequence Save Sequence ---------------------- Open Communication Format Save Communication Format ---------------------- Open PLC Output Layout Save PLC Output Layout ---------------------- Print out ---------------------- Exit Multi Communication Format Clear...
Page 17
F-TYPE NUTRUNNER SYSTEM USER CONSOLE 5.1 F-TYPE NUTRUNNER SYSTEM USER CONSOLE MENE STRUCTURE Fastening Fastening Data Torque/Current Curve View Tool Bar Key Pad Status Bar Security Log On Operation History Communication Units Configuration Software Configuration Software Version Window Cascade Vertical Horizontal Close All Windows - 17 -
Page 18
5.1 1 FILE OPERATION Select File (F) and below mentioned pull down menus appear. Load All Files Read all setting values from file. Save All Files Write all setting values in file. Open Parameter Read parameter value from file. Save Parameter Save parameter in file. Open Sequence Read sequence setting from file. Save Sequence Save sequence setting in file Open Communication Format Read communication format from file Save Communication Format Save communication format in file. Open...
Page 19
5.1.2 MULTI SETTING OPERATION Select MULTI (M) from menu bar and below mentioned pull down menus appear. Communication Format Clear Delete communication format. Communication Format Copy Copy communication format. Communication Format SetupEdit communication format PLC Output Clear Delete sequencer output allocation PLC Output Copy Copy sequencer output allocation. PLC Output Setup Edit sequencer output allocation. Multi Date/Time/Count Set date, time and cycle count. - 19 -
Page 20
5.1.3 SETUP OPERATION Select Setup (S) from menu bar and below mentioned pull down menus appear. Tool type setup Select tools Calibration Set CAL value Manual Reverse Speed Set reverse speed. Repeat Set number of repetition. Setup Mode Set step mode. 5.1.4 FASTENING RESULT DISPLAY OPERATION Select Fastening (F) from menu bar and below mentioned pull down menus appear. Fastening Data Displays tightening result. Fastening Torque/Current Curve Displays torque or current...