    4.5 External control interface 
     
    4.5.1  Type of external control interface 
    1) Digital I/O sink type 
    2) Digital I/O source type  (under development) 
    3) Device Net 
    4) InterBus  (under development) 
    5) Profibus  (under development) 
    Switching over to an external interface control requires an additional 
    exclusive board and SW1 setting in the following table.  SW1 setting is 
    determined and set at the time of shipment from our factory.  Be sure 
    not to change setting of SW1. 
     
     SW1-1 SW1-2 SW1-3 SW1-4 Type of interface 
    1 ON OFF OFF OFF Digital I/O sink type 
    2 OFF ON OFF OFF Digital I/O source type 
    3 ON ON OFF OFF Device Net-DT 
    4 OFF OFF ON OFF Device Net(E-stop)-DT 
    5 ON OFF ON OFF InterBus-DT 
    7 ON ON ON OFF ProfiBus-DT 
    9 ON OFF OFF ON Device Net-S 
    11 ON ON OFF ON InterBus-S 
    13 ON OFF ON ON ProfiBus-S 
     
     - 11 -  
    						
    							
     - 12 - 
    4.5.2 Digital I/O  
     
    4.5.2.1  Input signals (PLC 1) 
    NO Signal names Connections Functions 
    1 Preparation NC Stop signal suspends operation 
    2 System reset NO Reset main unit to resume initial status 
    3 Reverse NO Rotate anti-clockwise only while reverse 
    command signal is provided. 
    4 Stall NO Tightening  signal lasting 500ms gets this 
    function started. 
    5 Start NO Start  tightening. 
    6 Cycle start NO Get one operation cycle started. 
    7 Cycle count up NO Count up signal from internal cycle 
    counter.  A 500ms pul se signal will count 
    up 1 cycle. 
    8 Cycle count clear NO Reset  signal  from internal cycle counter. 
    A 500 ms pulse signal will reset (cancel) 
    counted numbers. 
    9 
    ~ 
    14 
    Step IN1 
     
    Step IN6 
     
    NO 
    This is to restart STEP which was 
    suspended by STEP OUT signal. 
    15 Judgment reset NO This is to reset each judgment. 
    16 Work select 9-16 change 
    signal NO Use this to change work select 9-16. 
    17 
    ~ 
    24 
    Work select 1 (9) 
    ~ 
    Work select 8 (16) 
     
    NO 
    This is to change work numbers which 
    has been selected. 
    25 
    ~ 
    28 
    OPTION 1 
    ~ 
    OPTION 4 
     
    NO 
    Assortment of bank select 1-4 does 
    output data bank change over. 
    29 Z/C check NO This is to check torque sensor. 
    30 Output bank select 1 NO 
    31 Output bank select 2 NO 
    32 Output bank select 4 NO 
    Output data bank change over 
    33 Input signal power 
    source NO 
    34 Input signal power 
    source NO 
    Common terminal and +24V 
    Note)  NC: Normal close  NO: Normal open 
    Table 4-1    Output data bank change over 
    Output bank 4 Output bank 2 Output bank 1 Output data bank 
    OFF OFF OFF 0 
    OFF OFF ON 1 
    OFF ON OFF 2 
    OFF ON ON 3 
    ・ 
    ・ 
    ・ 
    ・ 
    ・ 
    ・ 
    ・ 
    ・ 
    ・ 
    ・ 
    ・ 
    ・ 
    ON ON ON 7 
      
    						
    							
     - 13 - 
    4.5.2.2  Output signals (PLC 2) 
    Contents of output signals pin numbers  1-32 are for free format which is 
    for free allocation by customers.    The allocation can be made by user 
    console.  Main unit comes with dat a output bank setting 0 whose 
    allocation table is as mentioned below  (output data bank 1 to 7 are all 
    free format (pin numbers 1 to 32).   
    NO Signal names Connections Functions 
    1 TOTAL NOK NO Main unit outputs this signal when tightening 
    result was NOK.  This is output also when 
    NOK judgment was provided even for a single 
    spindle. 
    2 TOTAL OK NO Main unit outputs this signal when tightening 
    result was OK.    This is output only when OK 
    judgment was provided for all spindles 
    requiring judgment. 
    3 ALARM NO Main unit outputs this signal when system 
    abnormality has been detected. 
    4 READY NO Main unit outputs this signal while operation is 
    ready. 
    5 M RUN NO Main unit outputs this signal while    sequencer 
    program is in operation. 
    6 END NO Main unit outputs this signal when an 
    operation cycle has been completed. 
    7 Z/C CHECK NOK NO Main unit outputs this signal when NOK was 
    detected over zero and calibration check. 
    8 Z/C CHECK OK NO Main unit outputs this signal when OK was 
    detected over zero and calibration check. 
    9 
    ~ 
    14 
    Step OUT1 
     
    Step OUT6 
     
    NO 
    After a step is over and when jobs except for 
    tightening is required, main unit outputs this 
    signal. 
    15 OPTION 1 NO  
    16 Work select 9-16 
    Change answer 
    NO Main unit outputs this signal when work select 
    9-16 has been changed. 
    17 
    ~ 
    24 
    Work select 1 (9) 
    answer 
    Work select 8 (16) 
    answer 
     
    NO 
    Main unit outputs selected work numbers. 
    25 
    ~ 
    32 
    Not used 
    (free allocation) 
     
    NO 
    Free allocation can be made via users’ PC. 
    33 Output signal power 
    source  Common terminal for output signal. Connect 
    +0V. 
    34 Output signal power 
    source  Common terminal for output signal.    Connect 
    +0V. 
    Table 4-3 Sequence output select 
    Sequence 3 Sequence 2 Sequence 1 Seque nce 0 Selected sequence number 
    OFF OFF OFF OFF 1 
    OFF OFF OFF ON 2 
    OFF OFF ON OFF 3 
    OFF OFF ON ON 4 
         
    ON ON ON ON 16 
    ※ Note   Main unit comes with output signal numbers 1 to 6 (TOTAL OK  
    to END) which is determined and fix ed allocation from our factory.  
    						
    							
    Suitable plug 
     Manufacturer:  Honda 
     Name:  Small multipolar connector 
     PLC1:  MR-34F+MR-34L (case) 
     PLC2:  MR-34M+MR-34L (case) 
     
    Above comes with soldered connectors. 
     
     
    Input and output hardware 
    PLC2
    1KΩ
    2.2KΩ
    2.2KΩ
    1KΩ
    2.2KΩ
    2.2KΩ
    -+
    源DC24V電
    PLC1
    装置 PLCUト
    出
    出
    0V
    24V
    入
    入
    EC-MAINユニッ
    力信号
    力信号
    力信号
    力信号
    output signal
    outputsignal
    DC24V source 
    input signal
    input signal
    To PLC UEC-MAIN unit 
     
     - 14 -  
    						
    							
    4.6 Timing chart 
     
    ① Basic control signal 
     
     
    STOP
    R
    R
    S
    CYCLE COUNT UP
    M
    ALA
    EADY
    ESET
    TART
    締結動作
    総合OK
     RUN
    総合NOK
    RM
    END
    締結動作締結tightening tightening 
    STOP 
    READY 
    RESET 
    START 
    TIGHTENING OPERATION 
    M RUN 
    TOTAL OK 
    TOTAL NOK 
    ALARM 
    END 
    CYCLE COUNT UP 
     ②  Timing of tightening sequence signal and start 
    ワーク選択0
    STAR
    ワ
    ワ
    ワ
    ワ
    20ms以後に選択指令と選択結果信号で
    インターロックを取って下さい。
    シ
    シ
    ーケンス選択番号1
    ーケンス選択番号1Sequence select 1 
    Sequence select 1 
    Give OFF and ON interval minimum 20ms 
    to have  interlock 
    ワーク選択1
    ワーク選択3
    ワーク選択2
    Work select 0 
    Work select 1 
    Work select 2 
    Work select 3 
    T
    ーク出力0
    ーク出力1
    ーク出力3
    ーク出力2
    Work output 0 
    Work output 1 
    Work output 2 
    Work output 3 
    Start 
     
     
     - 15 -  
    						
    							
    5  F-TYPE NUTRUNNER SYSTEM USER CONSOLE 
    5.1 F-TYPE NUTRUNNER SYSTEM USER CONSOLE MENE STRUCTURE 
     
     
     
    File Load All Files 
    Save All Files  
     ---------------------- 
    Open Parameter 
    Save Parameter  
     ---------------------- 
    Open Sequence 
    Save Sequence 
     ---------------------- 
    Open Communication Format 
    Save Communication Format 
     ---------------------- 
    Open PLC Output Layout 
    Save PLC Output Layout 
     ---------------------- 
    Print out 
     ---------------------- 
    Exit 
    Multi Communication Format Clear 
    Communication Format Copy 
    Communication Format Setup 
     ---------------------- 
    PLC Output Clear 
    PLC Output Copy 
    PLC Output Setup 
    ------------------------ 
    Date/Time/Count 
    Setup Tool type setup 
    Calibration 
    Manual Reverse Speed 
    Repeat 
    Mode 
     
     - 16 -  
    						
    							
    F-TYPE NUTRUNNER SYSTEM USER CONSOLE 
    5.1 F-TYPE NUTRUNNER SYSTEM USER CONSOLE MENE 
    STRUCTURE 
     
     
     
    Fastening Fastening Data 
    Torque/Current Curve 
    View Tool Bar 
    Key Pad 
    Status Bar 
    Security Log On 
    Operation History 
    Communication  Units 
    Configuration Software Configuration 
    Software Version 
    Window Cascade 
    Vertical 
    Horizontal 
    Close All Windows 
     
     
     - 17 -  
    						
    							
    5.1 1  FILE OPERATION 
     
    Select File (F) and below mentioned pull down menus appear. 
     
     
     
    Load All Files Read all setting values from 
    file. 
    Save All Files Write all setting values in file. 
    Open Parameter Read parameter value from 
    file. 
    Save Parameter Save parameter in file. 
    Open Sequence Read sequence setting from 
    file. 
    Save Sequence Save sequence setting in file 
    Open Communication Format Read communication format 
    from file 
    Save Communication Format Save communication format in 
    file. 
    Open PLC Output Layout Read sequencer output 
    allocation from file. 
    Save PLC Output Layout Save sequencer output 
    Print out Print data on screen 
    File 
    Exit Print data on screen 
     
     - 18 -  
    						
    							
    5.1.2  MULTI SETTING OPERATION 
     
    Select MULTI (M) from menu bar and below mentioned pull down menus 
    appear. 
     
     
     
    Communication Format Clear Delete communication format. 
    Communication Format Copy Copy communication format. 
    Communication Format SetupEdit communication format 
    PLC Output Clear Delete sequencer output 
    allocation 
    PLC Output Copy Copy sequencer output 
    allocation. 
    PLC Output Setup Edit sequencer output 
    allocation. 
    Multi 
    Date/Time/Count Set date, time and cycle count.
     
     
     
     - 19 -  
    						
    							
    5.1.3  SETUP OPERATION 
     
    Select Setup (S) from menu bar and below mentioned pull down menus appear. 
     
     
     
    Tool type setup Select tools 
    Calibration Set CAL value 
    Manual Reverse Speed Set reverse speed. 
    Repeat Set number of repetition. 
    Setup 
    Mode Set step mode. 
      
    5.1.4 FASTENING RESULT DISPLAY OPERATION 
     
    Select Fastening (F) from menu bar and below mentioned pull down menus  
    appear. 
     
     
     
    Fastening Data Displays tightening result. Fastening  
    Torque/Current Curve Displays torque or current 
    curve. 
     
     
     - 20 -  
    						