    F-TYPE NUTRUNNER SYSTEM 
     
    MAIN UNIT 
     
    INSTRUCTION MANUAL 
     
     
     
     
     
     
    1ST EDITION JUNE 2001 
     
     
    URYU SEISAKU, LTD. 
     
     
     
      
    						
    							
     - 2 - 
    CONTENTS 
     
    1   OUTLINE                           4 
     
    1.1  How to use this instruction manual              4 
    1.2  Summary of functions                  4 
    1.3  Instructions for operation                5 
     
    2   SPECIFICATIONS                   6 
       
    2.1  Main specifications                  6 
      2.2  System structure layout                 6 
     
    3   PARTS NAMES                    7 
       
    3.1 Front panel             7 
     
    4   INSTALLATION AND WIRING                8 
       
    4.1 How to set up             8 
        4.2  External dimensions and mounting dimensions           8 
      4.3  Power plug connections                9 
      4.4  Control box layout                 10 
      4.5  External control interface               11 
      4.5.1  Type of external control interfaces            11 
     4.5.2 Digital I/O           12 
        4.5.2.1   Input signals   (PLC 1)             12 
        4.5.2.2   Output signals (PLC 2)             13 
      4.6  Timing chart                   15 
      
    						
    							
     - 3 - 
    5   F-TYPE NUTRUNNER SYSTEM USER CONSOLE         16        
     
    5.1  F-type nutrunner system user consol e menu structure         16  
      5.1.1 File operation           18 
        5.1.2.  Multi-unit setting value operation           19 
        5.1.3  Setting operation               20 
        5.1.4  Tightening result display operation           20 
        5.1.5  Display operation               21 
        5.1.6  Security setting operation             21 
        5.1.7  Parameter communication operation           22 
        5.1.8  System setting operation             22 
        5.1.9  Window setting operation             23 
     
     
      5.2  F-type nutrunner system user console basic operation         24 
        5.2.1  Initial display on PC screen             24 
        5.2.2  System setting screen               25 
          5.2.2.1  User console setting             25 
          5.2.2.2  Station setting               25 
        5.2.3  Parameter communication screen           26 
          5.2.3.1  Parameter communication screen         26 
        5.2.4  Parameter setting screen             27 
          5.2.4.1  Individual parameter setting screen         27 
        5.2.5  Parameter communication screen (2) Data writing       30  
    						
    							
     - 4 - 
    1 OUTLINE
    1.1  How to use this instruction manual 
    This instruction manual is explaining system structure, specifications, 
    and the handling etc of F-type nutrunner main unit. 
     
    1.2  Summary of functions 
    This is a fastener tightening system composed of newly developed 
    multi-spindle controller having re inforced communicational functions 
    being able to cope with everyday-evolv ing future-directive production 
    equipment.   
    ◆ This does not require complicated ladder circuit of sequencer for  multi-spindle control.  This has  made it possible to do simple 
    tightening sequence input by  easy-to-understand command 
    selection without professional kno wledge and has contributed to 
    remarkable job site operation time saving.  (Time reduction of 
    parameter change and preventi on of error manufacture) 
    ◆ You can make change of tighteni ng parameter, tightening sequence 
    or all settings under Windows 95, 98 or NT environment.    (※ See 
    below) 
    ◆ Maximum 31 spindle unit (sub controller and driver) are connected  and controlled by high-speed serial communication, which has 
    eliminated I/O wiring and terminal  connections of spindle unit to 
    sequencer. 
    ◆ This can be connected with all sort s of open network when main-unit 
    I/O module is replaced by a corre sponding one.  Communication 
    with external equipment is made via open network. 
    ◆ Status of whole system is protected  in case of spindle unit power off 
    due to emergency stop circuit.  Main unit, energized by 
    single-phase power supply 100V/200V, c an take and retain status of 
    whole system even if spindle unit  is switched off due to emergency 
    stop circuit. 
     
    ※  Windows: Trade marks of  Microsoft U.S.A.  
    						
    							
     - 5 - 
    1.3  Instructions for operation 
    Follow to the following instructions in order to use F-Type nutrunner 
    main unit under the best condition. 
     
    Use power cord conforming to specif ications for power supply to main 
    unit.  Lock connecting part of all connecting cables firmly.  Never 
    make common use of ground terminal  and high voltage circuit terminal.   
    Make separate connections of these terminals. 
     
    ◆  Mount main unit in a dust free control box. 
    Avoid main unit mounting in the below-mentioned places where 
    error operation or breakdown can  be caused.    Use different place 
    for main unit mounting.    Or, take counter measures to furnish the 
    dust free control box with co mpulsory cooling equipment. 
    ・ Place where main unit is disposed under direct rays of the Sun 
    or the temperature is out of  the specified range of 0-45 ℃. 
    ・ Place where relative humidity  is greater than specified range 
    20-90% or humidity variati on is abrupt giving dew. 
     
    Never use main unit in the following places. (Ask us if the probability\
     
    can be expected.) 
    ・ Places where you have conductibl e powders such as iron metal 
    powder, oil-mist, salinity or organic solvent. 
    ・  Place where you have corrosive  gas or combustible gas. 
    ・ Place where you have strong elec tric field or strong magnetic 
    field. 
    ・  Place where main unit receives  F-type motors’ strong vibration 
    or shock. 
     
    ◆  Be careful of static electricity because main unit is composed of 
    many electronic components.  Be sure to discharge static 
    electricity of your body by touchi ng a metal object before you touch 
    main unit because an excessive stat ic electricity can be generated 
    at dry air atmosphere. 
     
    ◆    When you clean circumference of  the main unit, never use kinds of 
    thinner of organic solvent which dissolves the paint coating or 
    penetrating in the main unit invi ting breakdown.    Use tepid water 
    or alcohol wet clothes for cleaning. 
      
    						
    							
    2 SPECIFICATIONS
    2.1 Main specifications 
    Power voltage Single-phase AC100-200V 
    Consumption 15W 
    Condition of operational 
    environment 
    Mount main unit in the dust free control 
    box.  Provide main unit with 
    compulsory cooling equipment or 
    heating equipment in case the 
    environment is out of the following 
    specifications. 
    Range of operational 
    temperature 
    0-45℃ and no dew 
    Range of operational humidity less than 90% and no dew 
    Condition of storage environmentTemperature: -5~55℃ 
    Humidity: less than 90% and no dew 
    Condition of transportation by 
    boat 
    Temperature: -5~55℃ 
    Humidity: less than 50% and no dew 
     
    2.2 System structure layout 
     
     
    RS232C CH2 
    Data reading 
    PLC 
    RS232C CH1 Tightening data Communication 
    RS232C CH3 Data display RS485 CH1 
    RS485     RS232C 
    Converter 
    Barcode 
    d
    UEC-F300M   NO.1             NO.31 
    Motors 
    D-NET 
    I-BUS Open network 
    User consoleDisplay unitPRINTER 
     - 6 -  
    						
    							
    3 PARTS NAMES
    3.1  Front panel 
    ① Power socket 
    AC100-200V Single-phase 
    ② Input/output connector (The details 
    in the separate table.) 
    PLC1: Input signal connector 
     For control signal input 
     (Fixed allocation) 
    PLC2: Output signal connector 
     For judgment result and status  
     output 
     (Free allocation) 
    ⑥
    ⑦①
    ②
    ⑤
    ④
    ③
    ⑨
    ⑧
    ⑩
    ③ Serial port (data input connector) 
    RS232C DATA-IN accepts serial 
    numbers etc provided by an external 
    equipment such as barcode reader 
    and outputs tightening data together 
    with serial numbers. 
    ④ Serial port (data output connector) 
    RS232C PRINTER outputs 
    tightening result data to printer (free 
    format). 
    ⑤ Serial port (data output connector) 
    RS232C PLC outputs tightening 
    result data to PLC (free format). 
    ⑥ Serial port (data output connector) 
    RS485 outputs tightening result data 
    to external intensive display unit. 
    ⑦ PC Connector 
    RS232C for communication with PC. 
    ⑧ PC-Spindle unit connector 
    RS485 for communication PC and 
    spindle unit. 
    ⑨ Manual switches 
    RESET, START, REVERSE and CAL 
    ⑩ LED Display 
    POWER, M RUN, OK, NOK and 
    ALARM 
     - 7 -  
    						
    							
    4 INSTALLATION AND WIRING
    4.1 How to set up 
    Follow to the below-mentioned instructions when you use F-type 
    nutrunner system. 
    No. Item Instructions 
    1 Use dust free control box Give main unit, spindle unit and dust free 
    control box specified intervals . 
    2 Use cooling or heating equipment.Have either one equipped as per 
    specifications. 
    3 Select control unit (input and 
    output signal selection). 
    Connect necessary signals. 
    4 Mount main unit and spindle unit. Mount main unit and spindle unit with 
    specified physical intervals. 
    5 Power cord connection with 
    power socket 
    Make connections by accessory 
    connectors. 
    6 Power supply Check wiring and connections.  Check 
    voltage before switching on. 
    7 Input all setting values Make value setting by a PC and input. 
    8 Initial action confirmation Make initial action confirmation. 
     
    4.2 External dimensions and mounting dimensions 
    Mounting 1 Mounting slot at upper part (Use M4 screw) 
     2 Deep holes at bottom part   (Use M4 screw) 
    Weight  1.4kg Main unit heat value 10W 
    Handling instructions Give approximately 100mm distance between main 
    unit bottom and dust free control box 
     
     
     - 8 -  
    						
    							
    4.3   Power plug connections 
     
    Use left bottom power socket to supply main unit with electricity. 
    Use accessory power cord which comes with main unit. 
     
    Suitable plugs 
    AC100~ AC220V single-phase 
    Not used 
    FG 
    Manufacturer AMP 
    Type: D3200S Rise.housing 
    Number: 1-178128-4 (keying X) 
    Type: Rise.contact (crimp type) 
    Number: 1-175218-2 
    Above comes with 2m cord with connectors 
     
     - 9 -  
    						
    							
    4.4  Control box layout 
    POWER
    BUSY
    ABNORMAL
    ACCEPT
    REJECT
    CM1
    CM2
    CM3RS232C COM3RS232C COM3
    RS232C COM1
    RS232C COM2RS232C COM2
    RS485
    START
    RESET
    REVERSE
    ~AC100~AC220
    POWER
    CAL
    PLC1
    PLC2
    REV
    MODESET
    START
    DATA
    RESETCAL
    BYPASS  RUN
    RS485
    ABNORMALACCEPTREJECT
    RESOLVERMOTOR
    AC IN 200~220V
    PLC
    SAN-12
      RUN
    SAN-12
    PLC
    AC IN 200~220V
    RS485
    RESOLVERMOTOR
    REJECT
    REV
    MODESET
    START
    DATA
    RESETCAL
    BYPASSABNORMALACCEPT  RUN
    AC IN 200~220V
    SAN-12
    PLC
    REJECT
    RS485
    RESOLVERMOTOR
    REV
    MODESET
    START
    DATA
    RESETCAL
    ACCEPTABNORMALBYPASSBYPASS
    REV
    MODESET
    START
    DATA
    RESETCAL
    RS485
    PLC
    SAN-12
      RUN
    AC IN 200~220V
    MOTORRESOLVER
    REJECTABNORMALACCEPT
    BYPASS
    REV
    MODESET
    START
    DATA
    RESETCAL
    RS485
    PLC
    SAN-12
      RUN  RUN  RUN
    SAN-12
    PLC
    AC IN 200~220V
    RS485
    RESOLVERMOTOR
    REJECT
    AC IN 200~220V
    SAN-12
    PLC
    REJECT
    RS485
    RESOLVERMOTOR
    REV
    MODESET
    START
    DATA
    RESETCAL
    BYPASSABNORMALACCEPT
    REV
    MODESET
    START
    DATA
    RESETCAL
    ACCEPTABNORMALBYPASS  RUN
    AC IN 200~220V
    SAN-12
    PLC
    MOTORRESOLVER
    REJECT
    RS485
    AC IN 200~220V
    RESOLVERMOTOR
    REJECT
    REV
    MODESET
    START
    DATA
    RESETCAL
    ABNORMALACCEPTBYPASSACCEPTABNORMAL
    REV
    MODESET
    START
    DATA
    RESETCAL
    AC IN 200~220V
    SAN-12
    PLC
    RS485
    RESOLVERMOTOR
    BYPASS  RUNACCEPTABNORMALREJECT
    MIN5
    50
    265
    100
    265
    100寸法は下記参照
    MIN5
    UEC-0**M
    Refer to the following for dimensions 
    Note) 024, 040 or 120 will be indicated instead of above 0**. 
     UEC-F024: 60mm 
     UEC-F040: 74mm (with fin inclusive) 
     UEC-F080: 105mm (with fin inclusive) 
     
     - 10 -  
    						