Page 11

 9  
Statistics 
Statistical Chart 
 
   
 
 
 
 
 
 
 
 
 
 
・Pick up data to display by selecting between All/OK/NOK in Search Criteria. 
・Data will be saved in CSV format with “F.6 Save”. 
・Start Controller memory data reception using “F.8 Receive”.    Any data will be accepted regardless 
of Search Criteria selection. 
・Memory data retained in Controller will be cleared when “F.9 Memory Clear” is selected. 
・The maximum memory data for total works is 1,500. 
 
Statistical Graph...

Page 12

10
Data 
・Select among All/1/2/3/4 to specify Work No. for data display.
(1)Whenis selected, Statistica
l Graph screen will appear. 
(2)To print out statistical data, select . 
(3)To return to Statistical Chart, select .  

Page 13

 11
Input/Output Check 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(1) Wiring condition check will be carried out through Input Terminal Block status monitoring 
and Output Terminal Block forced output.    Items now under Input ON or Output ON state 
are indicated in red and the ones now under OFF state are displayed in green. 
(2) Clicking an item now under ON state will turn it to OFF state, while clicking an item now 
under OFF state will turn it to ON state. 
(3) The item names correspondent to the names...

Page 14

12
Tool Management 
To
ol Name 
Type in “Model” and “Number”. 
Allowable Range: 0~14 characters Initial Value: 0 character 
Cycle Count/Cumulative Pulse Number  When the tightening number and the pulse number attained the values preset on Cycle Count 
Output and Cumulative Pulse Number Output, the messages input on Display Message columns 
will be displayed on Controller Unit and then outputs will be produced from the terminal block. 
Cycle Count Output 1/2  Allowable Range: 0~999999      Initial Value:...

Page 15

 13Environment Setting
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Communication Rate 
・Select from among “AUTO/19200/38400/57600/ 
115200 bps”. 
・In the case of AUTO setting, communication rate 
will automatically be recognized at the initial 
contact after setting. 
・Initial value for PC and Controller is both 
 38400bps. 
 
 
Note:  Changing  Controller  communication  rate  once  communication  has  been  established  with 
Controller at the initial contact under AUTO setting will cause a communication rate...

Page 16

AIMCO CORPORATE HEADQUARTERS 10000 SE Pine Street 
Portland, Oregon  97216  
Phone: (503) 254– 6600 
Toll Free: 1 -800- 852-1368  
AIMC

O CHINA  
Room 607, No. 3998 Hongxin Rd Dibao Plaza  
Minhang District, Shanghai   
China  
Phone: 0086 -21- 34319246  
Fax: 0086- 21-34319245
  LIT-MA
N730      Rev. 03/2016  
Printed in USA  ©2016 AIMCO AIMCO C
ORPORATION D E
 MEXICO S A DE CV 
Ave. C ristobal C olon 14529 
Chihuahua, C hihuahua.  31125 
Mexico 
P
hone: ( 01-614) 380- 1010 
Fax: (01 -614) 380- 1019...
Start reading Aimco Brakes Monitor UTM1500 Software Manual

Related Manuals for Aimco Brakes Monitor UTM1500 Software Manual

All Aimco Brakes manuals