PO Box \b6460, Portland OR 972920460 • 8008\f2\b368 • Fax 800\f8290\b\fwww.aimcoglobal.com Tightening Number Managing Controller UTM – \b\f00 Setting Software Instruction Manual (Setting Software V\b.4) (Main Unit Software V\b.04)
1 Contents Screen Layout ................................................................................................................................................................................................................ 2 Main Menu Screen......................................................................................................................................................................................................... 3 File Selection Screen ..................................................................................................................................................................................................... 4 Setting Screen................................................................................................................................................................................................................ 5 Final Data Reception ..................................................................................................................................................................................................... 6 Pressure Value Display Screen ..................................................................................................................................................................................... 7 Waveform Data Reception............................................................................................................................................................................................. 8 Statistics ........................................................................................................................................................................................................................ 9 Statistical Chart ............................................................................................................................9 Statistical Graph ...........................................................................................................................9 Data.............................................................................................................................................. 10 Input/Output Check .................................................................................................................................................................................................... 11 Tool Management ........................................................................................................................................................................................................ 12 Communication Rate.................................................................................................................... 13 Reception Setting.......................................................................................................................... 13
2 Screen Layout Menu Screen File Selection Setting Final Data Reception Pressure Value Display Waveform Data Statistics Input/Output Check Environment Setting Finish Tool Management Statistical Data Statistical Graph
3 Main Menu Screen This screen allows screen selection. (1) When is selected, “File Selection” screen will appear. (2) When is selected, “Setting Menu” screen will appear. (3) When is selected, “Final Data Reception” screen will appear. (4) When is selected, “Pressure Value Display” screen will appear. (5) When is selected, “Waveform Data Reception” screen will appear. (6) When is selected, “Statistics” screen will appear. (7) When is selected, “Input /Output Check” screen will appear. (8) When is selected, “Tool Management” screen will appear. (9) When is selected, “Environment Setting” screen will be displayed. (10) When is selected, the pop-up screen on the right will be displayed. Selecting will finish the software, while selecting will cancel finish option.
4 File Selection Screen ・Fil e Selection will appear first at the start of the software. (1)Select to create a new file, and click OK after typing in File Name” and “Tool/Work Name”. (2)Selecting while putting the cursor on a file to be deleted will call up the pop-up window shown on the right. Select to delete the selected file. (3)Select to change “Tool/Work Name”. (4)Selecting enables File Selection screen printout. To start printing, select on the screen shown on the right. (5)Select to save setting values on a floppy disk or other memory device. Touch while putting the cursor on a file to be saved and specify the intended save pl ace using the folder list window. (6) Select to import setting values from a floppy disk or other memory device upon specifying the import source using the folder list window. (7) Touch to return to Main menu. (8) File Selection will appear first at the start of the software.
5 Setting Screen ・”F.6 Save” selection allows setting value saving. Terminating the software or selecting another file es. Clicking a numerical setting column calls up Set Range Window. Input any value directly according to the range. For non-numerical setting, select any one from the menu upon right-clicking your mouse.
6 Final Data Reception Automatic Saving ・Checking “Auto Save” allows “data save place” and “file name” selection. ・Select between “Update on Time” and “Update on Size”. ・Input time interval when “Update on Time” is selected. Date will be updated at input time intervals. ・ Input size when “Update on Si ze” is selected. Data will be updated ev ery time when the input size is attained. Receiving Item Selection ・Right-click your mouse to call up the pertaining menu, and check any item to display. ・ Items without a checkmark will not appear but the corresponding data is in storage. ・To print out data received, select “ F.5 Print”. ・To save data received, select “F.6 Save”. ・To receive data, select “F.8 Receive”. will turn to under receiving conditions to halt communication. Data reception is effective continuously when returned to Main menu without halting communication. ・To return to Main menu, select “F.12 Main Menu”. PC’s date and time is shown as no date and time is available at Controller’s side. Data No. received
7 Pressure Value Display Screen ・This screen displays pressure values in real time. ・Zero point correction will be effected when “F.6 Zero Correction” is selected. If correction is effected at the time of 0.02V, pressure value after this operation will always take 0.00 [Mpa] at 0.02V.
8 Waveform Data Reception ・Waveform data will be displayed with the time axis enlarged, when “F.1 Enlarge” is turned on. ・Waveform data will be displayed with the time ax is reduced, when “F.2 Reduce” is turned on. ・Select “F.5 Print” to produce printout s of waveform data now on display. ・To save data received, select “F.6 Save”. (CSV format) ・Selecting “F.7 Import” will allow importin g of previously received and saved data. ・To receive waveform data, select “F.8 Receive”. ・ will turn to during receiving conditions to halt data reception. ・Data reception is effective continuously when return ed to Main menu without halting data reception. Preset Pressure Value Change ・ When “F.9 Pressure Setting” is selected, setting values of Tightening Start Pressure and Shutoff (Hitting Start in the case of TM or Standard Tool) can be changed. “F.9 Setting Save” will turn on during changing. ・ Upon pressure changing, setting values are saved with “F.9 Setting Save” and setting values are transmitted to Controller with “F.4 Setting Send”. ・Returning to Menu without saving will resume PC’s previous setting values. ・When “F.10 Display Clear” is selected, waveform data display will be cleared. ・To return to Main Menu, select “F.12 Main Menu”.