Aimco Brakes AcraDyne iEC iControl DC Tool Controller Users Guide
Here you can view all the pages of manual Aimco Brakes AcraDyne iEC iControl DC Tool Controller Users Guide. The Aimco Brakes manuals for AcraDyne are available online for free. You can easily download all the documents as PDF.
Page 81
35 Multiplier - Configures the tool to in clude gearing added to the base model. Units: Gear Ratio * 100. a. Example: Adding a multiplier with a gear ratio of 5:1, Multiplier setting = 5. Obstruction Torque - In 1st 90° degrees of rotation in the tightening direction cycle will be aborted if this torque is exc eeded. If the tool rotates 90° degrees and stops without any obstruction, the value is too low. Open Loop - After reaching the open position, this open loop torque prevents the...
Page 82
36 Figure 2.7.3 Tool calibration screen Buttons and LED’s Calibrate Buttons - After a tool has been worked on, it is possible the relationship between hall sensors and magnet have c hanged. Using the Tool Button Calibration screen calibrates the field between the two. Test Trigger, Ccw, Center and Cw positions and send the values to the Tool. LED States - Turns the tool lights on, off, or fl ashes. Used for testing of the Tool
Page 83
37 Figure 2.7.4 LED programming and button calibration Service and Calibration Log The Service Parameters are stored in the memory of the Tool and they can be viewed in this screen. The Next Service cycl e or Next Service date in this screen will turn red if they exceed the value the service is due.
Page 84
38 2.7.5 Tool Service and Calibration Log 2.8 Rundowns Data for rundowns in all or selected Parameter Sets can be displayed in a tabular format. This information can then be saved as a “Ms.csv” File. You can print the rundown results by using File ->Print in the menu. Rundowns must be saved to a file before the statistics function can be used to evaluate the data. Controller memory can be cleared by cl icking the “Clear iEC Rundown Memory” button 2.8.1 Download Data ...
Page 85
39 2.8.2 Select Parameter Set To view results of all saved rundow ns, regardless of Parameter Set, select zero (0) To view results of rundowns for a specific Parameter Set, select the appropriate Parameter Set number To select the colums you want to see, select custom and choose the columns from the selection menu You can restrict th e number of rundowns you want to see by selecting the Max. Rows (0 means all) The Rundowns are ordered by latest first. So the Re cent...
Page 86
40 Figure 2.8 Rundown Log example 2.9 Log Info Log info describes the usage of the Controller and the tools that have been used with that controller. POR Counts - Number of times the controller power has been cycled. Controller Cycles - Number of rundown the controller has completed. Tool Log - Displays history of tools that have been previously connected to the controller. Monthly Usage - Displays history of the number of rundowns the controller has preformed divided in to...
Page 87
41 Figure 2.9 Tool / controller Log Info example 2.10 Statistics The statistics page takes a collection of final torque samples from a rundown file then calculates and displays statisti cal information about the collecti on. In addition, a histogram is plotted, and the final torque for each rundown is displayed graphically. The maximum number of rundowns that can be evaluated is 2048. If more data is stored in the file, then data for only first 2048 rundowns are used. Tor que values are...
Page 88
42 Figure 2.10 Statistics screen example PSet Selection (Parameter Set): a. Only rundowns with the PSet selected are used in the collection. In addition, Only Rundowns with settings for Torque High Limit, Torque Low Limit, and Target that match the first rundown are used in the collection. b. If 0 is selected for the PSet, all rundow ns in the file will be used in the collection.
Page 89
43 Stats: POP: Population; The total number of observations used to calculate the statistical data. Mean: (Sum of All Readings) / (Number of Readings) CP: Overall capability, which is the ratio of 6 sigma to the tolerance. The equation for CP is: (Torque High Limi t – Torque Low Limit) / 6 Sigma CPK: Process capability, which takes both sigma and mean into account. The equation for CPK is the smaller of: (Torque High Limit – Mean) / 3 Sigma or (Mean – Torque Low...
Page 90
H T b d F a F Histogram o The histogra in, occurs i ivided in to T h of Th For referenc re taken fro Histogra The widt values f o Numb in the the nu the nu Rang samp of 0.1 Ran g samp increm Bin w Final Torqu of Final To am shows t n the colle c a specified he width f the freque o o Wher e he center p o ce, the Para om the first am adjustm h, center po or Range C ber of Bins e collection umber of bi umber of ru ge Ceiling A ple rounded ge Floor Ad ple...