    30-3439 AEMnet HARNESS INSTALLATION INSTRUCTIONS 
    ENGINEER: JT         DATE LAST MODIFIED: 7/9/2013  Page 1 of 4 
    Overview 
     
    The following instructions describe the proper installation of the AEMnet Harness 
    (30-3439), which is used to connect the Wideband Failsafe AEMnet 
    communication lines to a second (or multiple) AEMnet device(s). 
     
     
    Included Items 
    Item # Description Req. Quantity 
    30-3439 AEMnet Harness for Wideband Failsafe 1 
     
     
    Steps 
     
    1. Step 1 is Optional - 
    Disconnect the Wideband Failsafe 16-pin harness connector from the 
    Wideband Failsafe gauge. The harness connector has a latch on the bottom 
    side that needs to be squeezed as the connector is lightly freed from the 
    gauge. Refer to Figure 1 below. 
     
     Figure 1 
     
     
      
    						
    							 
     
     
     
     
    30-3439 AEMnet HARNESS INSTALLATION INSTRUCTIONS 
    ENGINEER: JT         DATE LAST MODIFIED: 7/9/2013  Page 2 of 4 
    2. Locate the green and white pre-crimped terminals on the end of the AEMnet 
    Harness. Figure 2 below shows the Wideband Failsafe connector and pinout 
    including the green and white leads from the AEMnet harness. 
     
     Figure 2 
     
    3. Before inserting the terminals into the connector, refer to Figure 3 to be sure 
    that the locking mechanism on the terminals is positioned properly in the 
    connector. 
     
     Figure 3 
     
      
    						
    							 
     
     
     
     
    30-3439 AEMnet HARNESS INSTALLATION INSTRUCTIONS 
    ENGINEER: JT         DATE LAST MODIFIED: 7/9/2013  Page 3 of 4 
    4. Insert the AEMnet+ terminal (white wire) into the available Pin 13 on the 
    Wideband Failsafe connector. Push the wire in until the locking mechanism on 
    the terminal and connector lock into place. Pull lightly on the white wire to 
    confirm the locking mechanism has latched. Figure 4 below shows the correct 
    placement of the AEMnet+ terminal. 
     
     Figure 4 
     
     
     
    5. Insert the AEMnet- terminal (green wire) into the available Pin 12 on the 
    Wideband Failsafe connector. Push the wire in until the locking mechanism on 
    the terminal and connector lock into place. Pull lightly on the green wire to 
    confirm the locking mechanism has latched. Figure 5 below shows the correct 
    placement of the AEMnet- terminal. 
     
     Figure 5  
    						
    							 
     
     
     
     
    30-3439 AEMnet HARNESS INSTALLATION INSTRUCTIONS 
    ENGINEER: JT         DATE LAST MODIFIED: 7/9/2013  Page 4 of 4 
     
    6. Reconnect the Wideband Failsafe 16-pin connecter to the gauge if it was 
    disconnected in Step 1. 
     
    7. Connect the Deutsch connector on the opposite end of the AEMnet harness to 
    a mating Deutsch connector on a second device with AEMnet capabilities. 
    The AEMnet harness includes a male and female Deutsch connector, allowing 
    AEMnet devices to be daisy-chained together. 
      
    						