Page 11
Page 11 DATA LOGGER The Water/Methanol Failsafe has an internal logger that can store approximately 2.5 minutes of injection data. The logger maintains two levels of data logs. First, all flow data points are stored and downloadable for viewing on the Flow vs. Injection Graph in the Water/Methanol Failsafe Configuration tab. Second, all injection events, inputs, outputs, and alarm triggers are logged in special log file format for viewing with the AEMdata software that comes as part of the...
Page 12
Page 12 Plot One Parameter Description Flow Measured flow rate in cc/min Lower Flow Limit Lower flow limit value as related to Injection Percentage Upper Flow Limit Upper flow limit value as related to Injection Percentage Plot Two Parameter Description Alarm Source Indicates what triggered the alarm condition; 1-low flow condition, 2-high flow condition, 3-auxiliary input, 4-alarm test Alarm Status Indicates state of alarm; 1-alarm triggered, 0-alarm not triggered Alarm Reset Counter...
Page 13
Page 13 OUTPUT CONFIGURATION The Water/Methanol Failsafe has two outputs that are triggered when an alarm condition exists; one +12 volt (high side) output and one ground (low side) output. These outputs can be used in a multitude of ways to reduce boost, pull timing, or otherwise protect an engine in the event there is a problem with the water/methanol injection system. The following is an index of possible auxiliary devices that can be triggered by the alarm outputs: AEM EMS Function...
Page 14
Page 14 NC/NO Relay The following are examples of how a NC/NO relay (Bosch PN 0-332-019-203 or similar) can be configured for use with the Water/Methanol Failsafe. Signal Interrupt − The high side (12 volt) output from the W ater/Methanol Failsafe can be used to turn on a NC (normally closed) relay and interrupt the output signal from a boost controller to its boost control solenoid – see Figure 1. Conversely, the low side (ground) output can also be used to trigger the relay − see Figure 2....
Page 15
Page 15 Warning Light The Water/Methanol Failsafe can also be used to directly activate a warning light (Autometer PN 3239 or similar). Connect the warning light black wire to ground and power the light with the high side output – see Figure 5. Alternatively, the low side output can also be used to turn the light on if the white wire is connected to +12V – see Figure 6. WATER/METHANOL FAILSAFE GAUGE The Water/Methanol Failsafe gauge comes with the black bezel installed...
Page 16
Page 16 Status Lights The Water/Methanol Failsafe gauge has two status lights (see below) that indicate when an alarm has been triggered. The left status light will turn on if there is a low flow alarm. The right status light will turn on if there is a high flow alarm. Both status lights will turn on if the auxiliary input is triggered. Analog Output The analog output from the Water/Methanol Failsafe is a linear dc voltage signal that varies with flow. The signal is used for...
Page 17
Page 17 Connector Pinouts The pinouts for the 3-pin sensor harness, 4 pin I/O harness, 8-pin power harness, and 5 pin USB harness are provided below. Voltage cc/min gal/hr 0.50 0 0.00 0.75 31 0.50 1.00 63 0.99 1.25 94 1.49 1.50 125 1.98 1.75 156 2.48 2.00 188 2.97 2.25 219 3.47 2.50 250 3.96 2.75 281 4.46 3.00 313 4.95 3.25 344 5.45 3.50 375 5.94 3.75 406 6.44 4.00 438 6.93 4.25 469 7.43 4.50 500 7.93 Voltage cc/min gal/hr...
Page 18
Page 18 12 Month Limited Warranty Advanced Engine Management, Inc. warrants to the consumer that all AEM High Performance products will be free from defects in material and workmanship for a period of twelve (12) months from date of the original purchase. Products that fail within this 12 month warranty period will be repaired or replaced at AEM’s option, when determined by AEM that the product failed due to defects in material or workmanship. This warranty is limited to...