– 11 – FUNCTIONS OF THE TOUCHPADS 1.DISPLAY WINDOW. Custom English Display Touchpads: These 2-line, 32- character Liquid Crystal Display (LCD) touchpads display protection point identification, system status, and messages. English Display Touchpads: Display protection zone ID and system status messages using pre-designated words. 2. 1 OFF KEY: Disarms burglary portion of the system, silences alarms and audible trouble indicators, and clears visual display after problems correction. 3. 2 AWAY KEY: Arms the entire burglary system, perimeter and interior. 4. 3 STAY KEY: Arms perimeter portion of burglary system only. Interior protection is not armed, allowing movement within premises without causing alarm. 5. 4 This is not a Function key. Used only as a numeric key. 6. 5 TEST KEY: Tests the system and alarm sounder if disarmed. Refer to TESTING THE SYSTEM section for test procedures. 7. 6 BYPASS KEY: Removes individual protection zones from being monitored by the system. 8. 7 INSTANT KEY: Arms in manner similar to STAY mode, but without the entry delay feature. Entering via the entry/exit door will cause an instant alarm. 9. 8 CODE KEY: Used to assign additional user codes for other users of the system . 10. 9 CHIME KEY: Turns CHIME mode on and off. When on, the opening of windows or doors while the system is disarmed will sound 3 beeps at the touchpad(s). 11. Q READY KEY: Used to display all open protection zones. 12. # KEY: This key can be used for Quick Arming of the system without use of a security code (if programmed). 13.KEYS 0–9† : Used to enter your security code(s). 14.READY INDICATOR: (GREEN) Lit when the system is ready to be armed (no faults present). While the system is disarmed, this indicator will go on and off as protection zones are closed and opened. 15.ARMED INDICATOR: (RED) Lit when the system has been armed. 16.INTERNAL SOUNDER: The built-in sounder mimics the alarm sounder during alarms, and will also beep during certain system functions. 17.EMERGENCY (PANIC) KEYS: Keys A, B, and C may all have been programmed for emergency functions; however, keys A and B may have been programmed for single button arming instead. For details, see PANIC KEYS section. 18.KEY D: This key may have been programmed for single- button paging (for details, see the SINGLE-BUTTON PAGING FEATURE section). † Note: Keys 1 through 3 and 5 through 9 each perform their associated companion system functions ( OFF, AWAY, STAY , etc.) when preceded by an entry of the security code (as described later).
– 12 – ARMEDREADY 6BYPASS 7INSTANT1OFFAWAY STAY 23 4TEST CODE CHIME READY 9 85 # 0 AC DB 1 4 3 2 175 18 8 1115 14 16 6 7 9 10 12 13 English Display Touchpad ARMED READY 6BYPASS 7INSTANT1OFFAWAY STAY 23 4TEST CODE CHIME READY 9 85 # 0 AC DB KEYPAD SHOWN WITHOUT SWING-DOWN FRONT DOOR 1 4 3 2 175 18 8 1115 14 16 6 7 9 10 12 13Custom English Display Touchpad (Touchpads shown without swing-down front door) IMPORTANT! •When entering codes and commands, sequential key depressions must be made within 10 seconds of one another. If 10 seconds elapse without a key depression, the entry will be aborted and must be repeated from its beginning. Be sure to observe this precaution when performing any of the procedures in this manual. •If you make a mistake while entering a security code, stop, press the [Q] key, and then start over. If you stop in the middle while entering a code, and then immediately start the entry over, an erroneous code might be entered.
– 13 – CHECKING FOR OPEN ZONES Using the Q READY Key Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING PROTECTION ZONES section), otherwise the touchpad will display a Not Ready message, and the READY indicator light on your touchpad will not be lit. The READY key can be used to display all faulted zones, making it easier for you to secure any open zone. To display faulted zones, simply press and release the READY [ Q] key (do not enter code first). Secure or bypass the zones displayed before arming the system. The the touchpad’s READY indicator light will come on when all protection zones have been either closed or bypassed. The system can then be armed if desired. READY TO DISPLAY OPEN ZONES, PRESS THE Q KEY. TYPICAL DISPLAYS WHEN NOT READY TO ARM DI S A R M E D - P RE SS Q TO SHOW FAULTSCUSTOM DISPLAY TOUCHPADTYPICAL DISPLAYS INDICATING OPEN PROTECTION ZONE (AFTER PRESSING READY KEY) FAULT 06BE DROOM WINDOWCUSTOM DISPLAY TOUCHPADTYPICAL DISPLAYS INDICATING READY TO ARM *** DI S A R M E D *** RE ADY TO ARM CUSTOM DISPLAY TOUCHPAD AC NOT READY Ê06 AC NOT READY AC ENGLISH DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD “ NOT READY” DISAPPEARS AND THE “READY” INDICATOR LIGHT COMES ON
– 14 – ARMING PERIMETER ONLY (With Entry Delay ON) Using the 3 STAY Key BEFORE ARMING,close all doors and windows(see CHECKING FOR OPEN ZONES ). THE STAY MODE ARMS THE PERIMETER, BUT ALLOWS USE OF THE ENTRY/EXIT DOOR. PERSONS WITHIN THE PREMISES CAN MOVE ABOUT FREELY. † Ask your installer if this feature is programmed in your system. If so, place a check in this box. Use this key when staying inside, but expect someone to use an entry/exit door later. It is also useful if you are leaving but someone is staying inside (or if you have pets which are moving throughout the premises. 1 . Enter your security code and press the STAY [3] key. In some systems, pressing the “B” key on on the touchpad for 2 seconds will arm the system STAY (no code is required). The “B” key may or may not have been programmed for this. Check with your installer. 2. The touchpad beeps three times and displays the armed STAY message (see displays below). The red ARMED indicator also lights. Note that there is an exit delay in effect before arming actually takes place. See the note below. 3 . After arming, an alarm sounds immediately if a protected perimeter window or non- entry/exit door is opened, but you may otherwise move freely within the premises. Anyone entering later can enter through an entry/exit door without causing an alarm, but they must disarm the system within the entry delay period to avoid sounding an alarm. † Exit Delay Restart. If you wish to open the entry/exit door to let someone in after arming STAY, you can re-start the exit delay at any time – simply press the [ Q] key, then let that person in. This avoids having to disarm the system and then re-arm it again. Note:When you first arm in the STAY mode, “You may exit now” will be displayed on a Custom Display Touchpad during the programmed exit delay. This delay is in effect even when arming STAY. When “You may exit now” disappears, the system is fully armed.TYPICAL DISPLAYS – “ARMED STAY” STAY AC ARME D *** STAY *** YOU MAY EXIT NOW ENGLISH DISPLAY TOUCHPAD CUSTOM DISPLAY TOUCHPAD
– 15 – ARMING PERIMETER ONLY (With Entry Delay OFF) Using the 7 INSTANT Key BEFORE ARMING,close all doors and windows(see CHECKING FOR OPEN ZONES ) THE INSTANT MODEARMS THE PERIMETER(INCLUDING ENTRY/EXITDOOR), WITH NO ENTRYDELAY. PERSONS WITHINTHE PREMISES CAN MOVEABOUT FREELY† Ask your installer if this feature is programmed in your system. If so, place a check in this box. Use this key when staying inside and do not expect anyone to use an entry/exit door. CAUTION:Arming the system in this mode will greatly increase the chance of false alarms. Use extreme care in selecting this mode of arming. 1 . Enter your security code and press the INSTANT [7] key. 2 . The touchpad beeps three times and displays the armed message. The red ARMED indicator lights. Note that there is an exit delay in effect before arming actually takes place. See the note below. 3 . After arming, an alarm sounds immediately if any protected perimeter door or window is opened, but you may otherwise move freely throughout the premises. An alarm sounds immediately if anyone opens an entry/exit door. † Exit Delay Restart. If you wish to open the entry/exit door to let someone in after arming INSTANT, you can re-start the exit delay at any time – simply press the [ Q] key, then let that person in. This avoids having to disarm the system and then re-arm it again. Note:When you first arm the system in the INSTANT mode, “You may exit now” will be displayed on the second line of a Custom Display touchpad during the programmed exit delay. This delay is in effect in the system even when arming INSTANT. When the exit delay period ends, “You may exit now” disappears and the system is fully armed in the INSTANT mode. TYPICAL DISPLAYS – “ARMED INSTANT” STAYINSTANT AC ARME D *INSTANT * YOU MAY EXIT NOW ENGLISH DISPLAY TOUCHPADCUSTOM DISPLAY TOUCHPAD
– 16 – ARMING ALL PROTECTION (With Entry Delay ON) Using the 2 AWAY Key BEFORE ARMING,close all doors and windows(see CHECKING FOR OPEN ZONES ) Use this key when no one will be staying inside. 1 . Enter your security code and press the AWAY [2] key. In some systems, pressing the “A” key on the touchpad for 2 seconds will arm the system AWAY (no code is required). The “A” key may or may not have been programmed for this. Check with your installer. 2 . The touchpad begins beeping and displays the armed AWAY message. The red ARMED indicator also lights. 3 . You must leave through an entry/exit door during the exit delay period to avoid causing an alarm. The touchpad will beep rapidly during the last 5 seconds of the exit delay to warn you that the delay is ending. After the exit delay expires, the system arms and will sound an alarm if a protected window or non-entry/exit door is opened, or if any movement is detected inside your premises. You may re-enter through an entry/exit door, but must disarm the system within the entry delay period to avoid an alarm. THE AWAY KEY ARMS THEENTIRE SYSTEM (INTERIORAND PERIMETER), BUTALLOWS USE OF THEENTRY/EXIT DOOR. TYPICAL DISPLAYS DURING EXIT DELAY [ AR M E D *** AWAY *** YOU MAY EXIT NOWCUSTOM DISPLAY TOUCHPADTYPICAL DISPLAYS AFTER EXIT DELAY (SYSTEM FULLY ARMED IN AWAY MODE) [ AR M E D *** AWAY *** ** AL L S E C U R E ** CUSTOM DISPLAY TOUCHPAD AWAY AC ENGLISH DISPLAY TOUCHPAD AWAY AC ENGLISH DISPLAY TOUCHPAD
– 17 – DISARMING AND SILENCING ALARMS Using the 1 OFF Key IMPORTANT: If you return and themain burglary sounderis on, DO NOT ENTER, butCONTACT THE POLICE froma nearby safe location.If you return after an alarmhas occurred and the mainsounder has shut itself off,the touchpad will beeprapidly upon yourentering, indicating thatan alarm has occurredduring your absence.LEAVE IMMEDIATELY, andCONTACT THE POLICE from anearby safe location. The OFF key is used to disarm the system, silence alarm and trouble sounds, and clear alarm memories. A BURGLARY alarm is a continuous/steady sound from the touchpads and any external sounders. To Disarm the SystemEnter your security code and press the OFF key. The Ready indicator light will be lit if all zones are secure, and the touchpad will emit a single tone to confirm that the system is disarmed.To Silence a Burglary AlarmSEE IMPORTANT NOTE AT LEFT!A BURGLARY alarm is a continuous/steady sound.Enter your security code and press the OFF key to silence the alarm (or warning tones of a Memory of Alarm). Note the zone in alarm on the touchpad display, and make that zone intact (close door, window, etc.). Now enter the security code plus OFF sequence again to clear the touchpads Memory of Alarm display. To Silence a Fire AlarmSimply press the OFF key to silence the alarm. Then enter the security code plus OFF sequence to clear the touchpads Memory of Alarm display. See FIRE ALARM SYSTEM section. TYPICAL BURGLARY ALARM DISPLAY ALARM 06BE DR OO M WIN DO W 06ALARM AC CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD
– 18 – BYPASSING PROTECTION ZONESUsing the 6 BYPASS Key LIMITATION The system will not allowfire zones to be by-passed.All bypasses are removedwhen an OFF sequence(security code plus OFF)is performed. This key is used when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first. 1 . Enter your security code and press the BYPASS [6] key. 2 . Enter the zone number(s) for the zone(s) to be bypassed (e.g., 06, 10, 13, etc.). Single digit zone numbers must be preceded by a zero (e.g. 05, 06) . 3 . When finished, the touchpad will momentarily display a Bypass message for each bypassed zone number. Wait for these zones to be displayed, to confirm their bypass. 4 . Arm the system as usual. Bypassed zones are unprotected and will not cause an alarm if violated while your system is armed. TO BYPASS ZONES:• Enter code.• Press BYPASS key.• Enter zone Nos.• Wait for bypassed zones to be displayed.• Arm system as usual. TYPICAL MOMENTARY DISPLAYS OF BYPASSED ZONE(S)BYPASS 06BE DROOM WINDOWCUSTOM DISPLAY TOUCHPADTYPICAL DISPLAYS AFTER ALL BYPASSED ZONES HAVE BEEN DISPLAYED (PRIOR TO ARMING) DISARMED BYPASSRE ADY TO ARMCUSTOM DISPLAY TOUCHPAD Ê06 BYPASS ACTHE “READY” INDICATOR WILL LIGHT TO SIGNIFY THAT THE SYSTEM IS READY TO ARM BYPASS AC ENGLISH DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD To display bypassed zones prior to arming (see displays above, right), enter your security code and press the BYPASS [6] key. This will also bypass any open zones at that time (if “Quick Bypass” is enabled – see following page).
– 19 – BYPASSING PROTECTION ZONES (Continued) Quick Bypass Ask your installer ifQuick Bypass is activefor your system, and ifso, check here: If your system supports Quick Bypass, it allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually. This feature is useful if, for example, you routinely leave certain windows open when arming at night. To use this feature, enter your security code and, within 10 seconds, press the BYPASS [6] key, then stop. In a few moments, all open zones will be displayed along with a Bypass message. Wait for all bypassed zones to be displayed, then arm the system.* *Make sure that only those zones that you wish to leave unprotected are bypassed, and that there are no other zones unintentionally left open. This feature will automatically bypass all open zones.TYPICAL MOMENTARY DISPLAYS TYPICAL DISPLAYS AFTER ALL BYPASSED ZONES OF BYPASSED ZONE(S) HAVE BEEN DISPLAYED (PRIOR TO ARMING) Ê02 BYPASS AC BYPASS AC ENGLISH DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD BYPASS 02RE AR DOOR CUSTOM DISPLAY TOUCHPAD DISARMED BYPASS RE ADY TO ARM CUSTOM DISPLAY TOUCHPAD TYPICAL DISPLAYS AFTER THE SYSTEM IS ARMED WITH BYPASSED ZONES AWAYBYPASS AC ENGLISH DISPLAY TOUCHPAD ARME D *** AWAY *** ZONE BYPASSE D CUSTOM DISPLAY TOUCHPAD
– 20 – CHIME MODE Using the 9 CHIME Key This feature can be usedonly while the burglarysystem is disarmed. Your system can be set to alert you to the opening of a perimeter door or window while it is disarmed by using CHIME mode. When activated, three tones will sound at the touchpad whenever a perimeter door or window is opened. Interior zones will not produce a tone when they are activated. Pressing the READY key will display the open protection points. To turn Chime Mode on: Enter the security code and press the CHIME [9] key. The CHIME message will appear. To turn Chime Mode off: Enter the security code and press the CHIME [9] key again. The CHIME message will disappear. TYPICAL DISPLAY WHEN CHIME IS ON DIS AR ME D C HIM ERE AD Y TO AR M AC CHIME CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD IN CHIME MODE, ANY OPEN PROTECTION POINTS WILL BE DISPLAYED WHEN THE “READY” KEY IS PRESSEDFA ULT 02REAR DOOR 02 AC NOT READY CHIME CUSTOM DISPLAY TOUCHPAD ENGLISH DISPLAY TOUCHPAD