–21– EXIT ALARMS Exit Alarm Warning Displays and Sounds Ask your installer if ExitAlarm Warning is activefor your system, and ifso, check here: Your system may support and have been programmed for this feature. When arming, if an exit or interior zone contains a fault during closing at the time the exit delay ends , the alarm sounder and keypad sound continuously to alert you that an unwanted alarm can be prevented if you take action: • If you disarm the system during the entry delay period that will immediately follow, the sound stops. The keypad displays CANCELED ALARM or CA as well as a zone indication. No message is transmitted to the central station. • If the system is NOT disarmed during the immediately following entry delay period, the sounds continue until the system is disarmed (or alarm sounder timeout occurs). The keypad displays EXIT ALARM or EA as well as a zone indication. An exit alarm message will be sent to the central station. Note: The latter EXIT ALARM conditions also result if an alarm from an exit or interior zone occurs within two minutes after the end of an exit delay. In any of the above cases, a second OFF sequence (security code + OFF key) will clear the keypad display. CHIME MODE Using the 9 CHIME Key This feature can be usedonly while the burglarysystem is disarmed. Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mode. When activated, three tones will sound at the Keypad whenever a door or window is opened. Pressing the READY key will display the open protection points. To turn Chime Mode on, enter the security code and press the CHIME key. The CHIME message will appear. To turn Chime Mode off, enter the security code and press the CHIME key again. The CHIME message will disappear.
–22– PANIC KEYS (FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS) Using Panic KeysYour system may have been programmed to use special keys or combinations of keys to manually activate emergency (panic) functions. The functions that might be programmed are: Silent Emergency, Audible Emergency, Personal Emergency, and Fire. A silent emergency sends a silent alarm signal to the central station*, but there is no audible alarm or visual display. An audible emergency sends a signal to the central station* and sounds a loud, steady alarm at your keypad(s) and at any external sounders that may be connected (ALARM plus a zone number is also displayed). A personal emergency alarm sends an emergency message to the central station* and sounds at keypad(s), but not at external bells or sirens. A fire alarm sends a fire alarm message to the central station* and uniquely sounds at keypad(s) and external bells and sirens (FIRE plus a zone number is also displayed). * If connected to a central station.TO INITIATE A PANIC FUNCTION AT ANY TIME OF DAY OR NIGHT:• Press an active lettered key (A, B or C) for at least two seconds. or, if lettered keys are not present on the keypad,• Press both keys of an active pair at the same time. See next page for panic functions that have been assigned to keys. Also see Duress Code feature on page 10.
–23– PANIC KEYS (Continued) CHECK IF PANIC PLACE A CHECK NEXT TO PROGRAMMEDZONEACTIVE KEY(S)FUNCTION NUMBER [A]____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 9 5 [B]____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 0 7 SEE YOUR INSTALLER [C]____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 9 6 AND NOTE HEREOR THE KEY(S) & FUNCTION(S) [1] & [Q]____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 9 5 PROGRAMMED [Q] & [#]____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 0 7 FOR YOUR SYSTEM [3] & [#]____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 9 6 • KEYS [A], [B], AND [C] ARE NOT PRESENT ON ALL KEYPADS. • KEY [D], IF PRESENT ON YOUR KEYPAD, IS NOT ACTIVE HERE. OUTPUT RELAY OPTIONS Programmed Actions Ask your installer to provide information on any special system actions that have been programmed during installation. (in response to ACTION STARTED B Y ST OPPED BY zone activity or manual entries)
–24– TESTING THE SYSTEMTO BE CONDUCTED WEEKLY Using the 5 TEST Key NO ALARM REPORTSWILL BE SENT TO THECENTRAL MONITORINGSTATION while thesystem is in Test mode. The TEST key puts your system into the Test mode, which allows each protection point to be checked for proper operation. 1 . Disarm the system and close all protected windows, doors, etc. The keypads READY message should be displayed and the READY indicator (if present) should be lit. 2 . Enter your security code and press the TEST key. 3 . As the Test mode is entered, the external siren or bell will sound for 2 seconds and then turn off. Each time a protection zone is faulted, the keypad sounds 3 beeps. The keypad will sound a single beep every 40 seconds as a reminder that the system is in the test mode. If these sounds do not occur, call for service immediately. 4 . Open and close each protected door and window in turn and listen for the required sounds The identification of each faulted protection point should appear on the dis- play. 5 . Walk in front of any interior motion detectors (if used) and listen for the required sound as movement is detected. The identification of the detector should appear on the display when it is activated.Note: Wireless PIR (Passive Infrared) units will send signals out only if they have been inactive for 3 minutes. 6 . Follow the manufacturers instructions to test all smoke detectors, to ensure that all are functioning properly. The identification of each detector should appear on the display when each is activated.
–25– TESTING THE SYSTEM (Continued) 7 . After all protection points have been checked and restored, there should be no zone identification numbers displayed. If a problem is experienced with any protection point (no confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY. 8 . Turn off the Test mode by entering the security code and pressing the OFF key. PAGING FEATURE If the paging feature has been programmed for your system, your pager will respond to certain conditions as they occur in your system by displaying a 10-digit code that will indicate the type of condition that has occurred. The 10- digit code will use the following format: SSSS–EEE–NNN SSSS will be your particular 4-digit subscriber No. (this same number will always appear at the beginning of the display on your pager). EEE will be a 3-digit number that describes the event that has occurred in your system (see explanation below). NNN will be a 3-digit User or zone number, depending on the type of event that has occurred. The 3-digit Event Codes (EEE) that can be displayed are: 911 = Alarm (NNN that follows this code will be the zone number that has caused the alarm) 001 = Open, System disarmed (NNN that follows this code will be the User number) 002 = Close, System armed (NNN that follows this code will be the User number) 811 = Trouble (NNN that follows this code will be the zone number that has caused the trouble)Example 1. Pager displays: 1234–911–004Ê This indicates that your system (Subscriber No. 1234) is reporting an Alarm (911), due to zone 4 (004) being faulted.Example 2. Pager displays: 1234–00 1–00 5Ê This indicates that your system (Subscriber No. 1234) is reporting an open/disarming (001) by User 5 (005).
–26– TROUBLE CONDITIONS Check and Battery Displays * Not all systems usewireless sensors. The word CHECK on the keypads display, accompanied by a beeping at the keypad, indicates a trouble condition in the system. To silence the beeping for these conditions, press any key. 1.A display of CHECK and one or more zone numbers indicates that a problem exists with the displayed zone(s) and requires your attention. If the CHECK display relates to a fire zone, CALL FOR SERVICE IMMEDIATELY. Determine if the zone(s) displayed are intact and make them so if they are not. If the problem has been corrected, the display can be cleared if you enter the OFF se- quence (security code plus OFF key) twice. If the display persists, CALL FOR SERVICE . 2.If there are wireless sensors* in your system, the CHECK condition may also be caused by some change in the environment that prevents the receiver from hearing a particular sensor. CALL FOR SERVICE if this occurs. IF YOU CANNOT CORRECT A CHECK DISPLAY, OR IF IT IS FOR A FIRE ZONE, CALL FOR SERVICE IMMEDIATELY. TYPICAL CHECK DISPLAYS CHECK 06 FRONTUPSTAIRS BEDROOM ALPHA ÊÊ06 CHECKAC FIXED-WORD
–27 – TROUBLE CONDITIONS (Continued)Words or letters in parentheses ( ) are those that are displayed on Fixed-word keypads. ¯ Other Trouble Displays * Any “beeping” that accompanies a trouble display can be stopped by entering an OFF sequence (code + OFF)** Not all systems use wireless transmitters. 1.COMM. FAILUREIndicates that a failure has occurred in the telephone com- (or FC) munication portion of your system. CALL FOR SERVICE IMMEDIATELY. 2.SYSTEM LO BATIndicates that a low system battery condition exists, and (or BAT with no zone No.)accompanied by a once-per-minute beeping* at the Keypad. If this condition persists for more than one day (with AC present), CALL FOR SERVICE. 3.LO BAT + zone descriptor Indicates that a low battery condition exists in the wireless (or BAT with zone No.)transmitter** number displayed, and accompanied by a once-per-minute beeping* at the Keypad. Either replace the battery yourself, or CALL FOR SERVICE. If the battery is not replaced within 30 days, a CHECK display may occur. Some wireless sensors contain a non-replaceable long-life battery which requires replacement of the entire unit at the end of battery life (e.g., 5802 Pendant and 5802CP Belt Clip Personal Emergency Transmitters and 5803 Wireless Key Transmitters). 4.MODEM COMM (or CC)Indicates that the control is on-line with the central stations remote computer. The control will not operate while on- line. Wait a few minutes. The display should disappear.
–28 – TROUBLE CONDITIONS (Continued) Other Trouble Displays (Continued)5.AC LOSS is displayed The system is operating on battery power only due to a (or NO AC) power failure. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary. CALL FOR SERVICE if AC power cannot be restored to the system. 6.Busy-Standby (or dI)If this remains displayed for more than 1 minute, system is disabled. CALL FOR SERVICE IMMEDIATELY. 7.OPEN CIRCUIT The keypad is not receiving signals from the control. (or OC) 8.Long Rng TrblIf programmed, back-up Long Range Radio communica (or bF) tion has failed. CALL FOR SERVICE . Total Power FailureIf there is no keypad display at all, and the POWER indicator (if present) is not lit, operating power (from AC and back-up battery) for the system has stopped and the system is inoperative. CALL FOR SERVICE IMMEDIATELY. FOR SERVICING INFORMATION, SEE PAGE 43
–29– FIRE ALARM SYSTEM (IF INSTALLED) GeneralYour fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will au- tomatically send signals to your system, triggering a loud, interrupted pulsed sound* from the Keypad(s). This sound will also be produced by optional exterior sounders. A FIRE message will appear at your Keypad and remain on until you silence the alarm (see below for silencing fire alarms). * Temporal pulse sounding is produced for Fire alarms, as follows: 3 pulses–pause–3 pulses–pause–3 pulses. . . , repeated. TYPICAL FIRE EMERGENCY DISPLAYS FIRE 05MASTER BEDROOM 05ALARM FIRE AC ALPHA FIXED-WORD Silencing Fire Alarms1 . You can silence the alarm at any time by pressing the OFF key (the security code is not needed to silence fire alarms). To clear the display, enter your code and press the OFF key again (to clear Memory of Alarm). 2 . If the Keypads fire indication does not clear after the second OFF sequence, smoke detectors may still be responding to smoke or heat producing objects in their vicinity. Investigate, and should this be the case, eliminate the source of heat or smoke. 3 . If this does not remedy the problem, there may still be smoke in the detector. Clear it by fanning the detector for about 30 seconds. 4 . When the problem has been corrected, clear the display by entering your code and pressing the OFF key.
–30– FIRE ALARM SYSTEM (Continued) Manually Initiating a Fire Alarm1 . Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest Keypad and manually initiate an alarm by pressing the appropriate panic key(s), assigned for FIRE emergency (if programmed by the installer). Check below, and on page 23. 2 . Evacuate all occupants from the premises. 3 . If flames and/or smoke are present, leave the premises and notify your local Fire De- partment immediately. 4 . If no flames or smoke are apparent, investigate the cause of the alarm. The zone number(s) of the zone(s) in an alarm condition will be displayed at the Keypad. Ask your installer which lettered key, or key pair, has been assigned for manually initiating a FIRE alarm, and place a check mark in the box next to the assigned key or key pair. CHECK LETTERED KEY ¯ASSIGNED FOR FIRE ¯ CHECK KEY PAIR ASSIGNED FOR FIRE A OR PRESS 1 and Q AT THE SAME TIME B OR PRESS Q and # AT THE SAME TIME C OR PRESS 3 and # AT THE SAME TIME Press and hold the lettered key assigned for Fire emergency for 2 seconds . If the keypad does not have individual lettered keys, Press the key pair assigned for Fire emergency.