Home
>
ADS
>
Monitoring system
>
ADS FlowShark HV Operation and Maintenance Manual QR 775005 A2 July 2010
ADS FlowShark HV Operation and Maintenance Manual QR 775005 A2 July 2010
Here you can view all the pages of manual ADS FlowShark HV Operation and Maintenance Manual QR 775005 A2 July 2010. The ADS manuals for Monitoring system are available online for free. You can easily download all the documents as PDF.
Page 21
ADS FlowShark HV O&M Manual 21 Maintenance Perform routine maintenance on the FlowShark HV to maintain optimal performance and maximize the life of the components . The maintenance interval and scope may vary based on operational and environmental conditions and practical experience obtained over time. However, the f ollowing are some general maintenance procedures ADS recommends implementing for the FlowShark HV : Clean the control unit and sensor after every measurement. Wash t...
Page 23
ADS FlowShark HV O&M Manual 23 Troubleshooting The following tables contain general techniques for troubleshooting and resolving problems that may occur with the FlowShark HV . Problem FlowShark HV will not turn on. Possible Causes Battery voltage is too low. Surrounding temperature is outside the specifi ed operating temperature. Possible Solutions Recharge battery. Warm or cool equipment. Problem Measurement value will not display or is fluctuating. Possible Causes Sensor is...
Page 25
ADS FlowShark HV O&M Manual 25 Technical Specifications The following tables include the technical specifications for the components comprising the FlowShark HV and the CE guidelines. When applicable, certain s pecifications may reflect using the equipment under optimal operational and environmental conditions. Individual specifications also may include details concerning possible external influences or conditions that may affect the velocity data obtained. Cont rol Unit The following...
Page 26
26 ADS FlowShark HV O&M Manual Sensor The following t able contains the specifications for the sensor probe for velocity measurement. Material Stainless steel and p olyurethane Rating IP68 (NEMA 6) Removable Rod Material : Aluminum ( telescopic) with bubble level Length: 28 to 63 inches (0.7 to 1.6 meters) Emitting Frequency 750 kHz Measurement Window Position: 2.36 inches (6 cm) along the horizontal axis in front of the sensor Length: 1.18 inches (3 cm) Diameter: 0.63...