ADS FlowShark HV O&M Manual  21 
 Maintenance 
Perform routine maintenance on the FlowShark HV  to maintain optimal performance 
and maximize the life of the components .  The maintenance interval and scope may 
vary based  on operational and environmental conditions and practical experience 
obtained over time.  
However, the f ollowing are some  general maintenance procedures ADS recommends 
implementing for the FlowShark HV : 
  Clean  the control unit and sensor after every measurement. 
  Wash t...

Page 22


				            

Page 23

ADS FlowShark HV O&M Manual  23 
 Troubleshooting 
The  following tables contain general techniques for troubleshooting and resolving 
problems that may occur with the FlowShark HV . 
Problem FlowShark HV will not turn on. 
Possible 
Causes 
Battery  voltage is too low.  
Surrounding temperature  is outside  the specifi ed operating temperature. 
Possible 
Solutions  Recharge battery.  
Warm or cool equipment. 
 
Problem Measurement value  will not display or is fluctuating. 
Possible 
Causes 
Sensor is...

Page 24


				            

Page 25

ADS FlowShark HV O&M Manual  25 
 Technical Specifications 
The following tables include the technical specifications for the components 
comprising the FlowShark HV  and the CE guidelines.  When applicable, certain 
s pecifications may reflect using the equipment under  optimal operational and 
environmental  conditions.  Individual specifications also  may include details 
concerning possible external influences  or conditions that may affect the velocity data 
obtained. 
Cont rol Unit  
The following...

Page 26

26 ADS FlowShark HV O&M Manual  
Sensor 
The following t able contains the specifications for the sensor  probe for velocity 
measurement.  
Material Stainless steel and p olyurethane 
Rating IP68 (NEMA 6)  
Removable 
Rod 
Material :  Aluminum ( telescopic) with bubble level  
Length:  28  to 63 inches (0.7 to 1.6 meters)  
Emitting 
Frequency 
750 kHz 
Measurement 
Window  
Position:  2.36 inches (6 cm) along the horizontal axis in front of 
the sensor  
Length:   1.18 inches (3 cm)  
Diameter:   0.63...