Page 71
70 5. APPENDIX 5.1. Sending status information and sensor values using rules The administrator can create rules (see Settings/Rules) to trigger actions and send personalized messages in form of Syslog messages, SNMP traps or emails when an event occurs. Moreover, the administrator also has the possibility to complete his messages with status information of an input (a power supply or a door contact for example) or the value of a sensor (a temperature sensor for example). In the...
Page 72
71 5.2. Ping and Scan Methods ePowerSwitch 8XM has two methods to check whether an IP equipment (PC, server, router, Webcam...) is still alive: Address Pinging: The first method uses the well-known Ping command whereby a request is sent to a specific IP address. The Ping command, which is an echo request, enables you to determine through an ICMP protocol (Internet Control Message Protocol) if an IP device is available on the network. If the system reacts to this request, ePowerSwitch 8XM knows...
Page 73
72 5.3. Technical Data Network standards: IEEE 802.3, 10 / 100 BASE-T Network protocols: TCP/IP, HTTP/HTTPS Network connection: RJ-45 connector for STP CAT5 Max. network cable length 100 meters Serial connection: RS232, SUB-D 9 female SSL Technology: Version 2 and 3 Operating temperature: 0°C to +40°C Operating humidity: 10% to 80% RH (not condensing) Dimensions (LxDxH): 170 x 110 x 42 mm Weight: 0,63 kg Approvals: CE, EN55022 & EN55024 5.4. Commonly used Ports TCP 25:...
Page 74
73 5.5. Syslog Messages: Severity Level Definitions The Emergency level is the most severe type of message generated by ePowerSwitch 8XM and the Debug severity level is the least severe one. Severity Level 0, Emergency: The following messages appear at severity 0: - Continuous error! - An SMTP Client could not be created Severity Level 1, Alert: The following messages appear at severity 1: - Settings have been reinitialized through the serial connection - ePowerSwitch 8XM does not respond...
Page 75
74 Severity Level 6, Informational: The following messages appear at severity 6: - System has been started - Date & Time have been synchronized to a Network Time Server - User name : Outlet (number) of Master M0 has been switched ON - User name : Group (number) has been switched ON - Dry Contact Input (number) has been opened - Dry Contact Input (number) has been closed - Dry Contact Output (number) has been opened - Dry Contact Output (number) has been closed - Mail subject has been sent to...
Page 76
75 STATEMENT OF CONFORMITY All modifications reserved STATEMENT OF CONFORMITY NEOL S.A.S. declares that this equipment is in compliance with the Electromagnetic Compatibility Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC Application of Council Directives: 89/336/EEC, 92/31/EEC, 73/23/EEC, 93/68/EEC Standards to Which Conformity declared: EN 60950, EN 55022, EN 55024 Manufacturers Name and Address: NEOL S.A.S 4 Rue Nationale...