Page 11

 
© Adam Equipment Company 2005  
  9
 
6.5 
cont = CONTINUOUS PRINTING 
 
 
This  parameter  is  used  to  configure  to  print  contin uously  whenever 
there is any weight on the balance or only when  [Print] is pressed. 
 
  To set the parameter press the  [Func] key to show “ cont” 
   Press  [Print] to see the parameter. 
   Press  [Print] to select either “ cont= 0” or “cont= 1 ”. 
“ cont= 0 ”  Continuous output is disabled. Prints only when t he 
[Print]  key is pressed. 
“ cont= 1 ”...

Page 12

 
© Adam Equipment Company 2005  
  10
 
of parts. If more items are added or removed from t
he balance, 
the display will show the new quantity.  
  Note that the display is limited to 6 digits, i.e.  999,999 pieces. If 
the quantity on the scale exceeds 999,999 the left  most digits and 
any leading zeros will be lost, for example 1,002,3 05 will display 
as 2,305 pieces. 
 
  When in use the balance can be tared normally to e liminate the 
package weight from the gross weight.  
 
  To return to...

Page 13

 
© Adam Equipment Company 2005  
  11
 
6.7 
StEPS = CHECK-WEIGHING FUNCTION (LOW-OK-HIGH) 
 
  The check-weighing function will show a symbol on  the left side of 
the display to indicate if the current weight displ ayed is: 
 
   - above the  High setpoint  
   
  - between the  setpoints  
 
   - below the  Low setpoint   
 
  To  enable  the  check-weighing  function  and  set  the  value  of  the 
setpoints press the  [Func] key until “ StEPS” is displayed. 
 
  Press  [Print]  to  enter  the...

Page 14

 
© Adam Equipment Company 2005  
  12
 
6.8 
CALIbr   = CALIBRATION ROUTINE 
 
  To set the parameter press the  [Func] key to show “ CALIbr”. 
 
  Remove all weight from the platform. 
 
  Press  [Print]  and  the  display  will  show  “ noCAL”  while  the  scale  is 
measuring the initial mass (pan must be empty).  
 
  Then  the  display  will  show  “ LOAd      xxx”  where  xxx  is  the  required 
calibration weight. 
 
  Place  the  weight  on  the  platform  then  press  [Print]  –  display...

Page 15

 
© Adam Equipment Company 2005  
  13
 
6.10 
StAb = PRINT WHEN STABLE or INSTANTANEOUS 
 
  When  the  scale  is  set  to  manual  print  ( rePL  =  0),  the  balance  can 
be  set  to  print  either  immediately  after  the  [Print]  key  is  pressed 
or  only  after  the  balance  is  stable.  The  function  c an  also  be 
enabled  from  the  RS-232  interface.  See  Section  3:  
Communication with a Computer or Printer.  
 
   To set the parameter press the  [Func] key to show “ StAb”. 
 
...

Page 16

 
© Adam Equipment Company 2005  
  14
 
6.12 
t1 = AUTOMATIC POWER SWITCH OFF 
 
The  scale  includes  an  internal  battery.  The  typical   operation  time  using  only 
the  battery  is  50  hours  if  one  load  cell  is  used  an d about 12 hours if four are 
used. The scale includes the “ t1” function to turn the power off after 5 minutes 
if it is not being used. This function can be disab led if the balance is powered 
from  the  main  power  supply  or  if  the  disruption  of  power  affect...

Page 17

 
© Adam Equipment Company 2005  
  15
 
6.15 
SuPP = Power supply voltage to PCB 
 
  To set the parameter press the  [Func] key to show “ SuPP”. 
   Press  [Print] to see the parameter. 
   The display will show the current voltage to the P CB. 
   Press any key to return to normal weighing. 
 
7.0  COMMUNICATION WITH A COMPUTER/PRINTER 
 
The following applies only to scales supplied with  an RS-232 interface. 
 
  Press  the  [Print]  key  to  transmit  weighing  data  (value  and  unit  of...

Page 18

 
© Adam Equipment Company 2005  
  16
 
If the output connector is a 6 pin audio connector.
 The output pins are: 
 
         
 
It  is  necessary  to  jumper  pin  1  to  pin  6  to  enable  the  RS-232  interface 
circuits. Do not connect these pins to the handshak ing pins on the interfaced 
device.    
7.3  OUTPUT FORMAT 
 
The balance will output the weight with the units o f measure on one line. The 
output is initiated when the  [Print] key is pressed or a command is received 
over the RS-232...

Page 19

© Adam Equipment Company 2005 
Manufacturer’s Declaration of Conformity 
This product has been manufactured in accordance with the harmonised European standards,  following the provisions of the below stated directives: 
Electro Magnetic Compatibility Directive 89/336/EEC  Low Voltage Directive 73/23/EEC 
 Adam Equipment Co. Ltd. 
Maidstone Road, Kingston,  
Milton Keynes, MK10 0BD  United Kingdom 

FCC COMPLIANCE 
This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a...

Page 20

© Adam Equipment Company 2005 
ADAM  EQUIPMENT
  is  an  ISO  9001:2000  certified  global  organisation  with  more  than  30 
years  experience  in  the  production  and  sale  of  electronic  weighing  equipments.  Products 
are sold through a world wide distributor network -supported from our company locations in 
the UK, USA and SOUTH AFRICA. The company and their distributors offer a full range of 
Technical  Services  such  as  on  site  and  workshop  repair,  preventative  maintenance  and...
Start reading Adam Equipment AELP Pallet Beams AELPREVA6 User Manual